SER
VICING
82
PULSE Installation, Commissioning and Servicing Manual - Revision 19
12.16 View/Set Date & Time
Setting the date and time ensures that the time stamps on Transaction and Error Logs
are correct.
$
L
$
L
$
L
$
L
The display will show
DATE
in the Dollars display and the current
Central Controller date in the Litres display.
To set the date, press
f
. The Dollars display shows
DATE*
An asterisk (
*
) after the function name indicates that
the system is in edit mode.
Enter the date (DDMMYY). Note that if the date is entered using
all six figures, there is no need to confirm entry, i.e. the system
automatically accepts and acts on the entered date. If less than
six digits are entered, press
f
to confirm the new date.
The Dollars display shows
DATE
(without the asterisk) to indicate
that the UI is back in ‘view date’ mode.
Press
2
to move to
TIME
and set in the same manner.
Gallagher advise the checking of the date and time when obtaining dispenser logs.
Should either be incorrect, make a note to be included with the logs. This will
assist in finding the events being investigated.
12.17 Maintaining Isolation of Mains Voltage within Head Cabinet
The perspex cover within the User Interface may be removed by suitably qualified persons
for servicing, to gain access to the SD Card, cables, etc.
This cover MUST always be replaced. Under no circumstances can the dispenser be placed
into service without this cover in place.
Be aware that the User Interface of all PULSE Dispensers may be opened as part of normal
operation (e.g. to change the advertising sheet), therefore live parts must not be left
exposed to possible human contact.
Version 1.11