SER
VICING
93
PULSE Installation, Commissioning and Servicing Manual - Revision 19
15.8.3 Safety feature supplementing excess flow rate - XS FLOW
The XS FLOW supplements the physical excess flow valve safety feature. Where an excess
flow rate situation occurs the dispenser will cycle the delivery speed down or terminate
the delivery to prevent the physical excess flow valve from activating unnecessarily. This
event will cause a non-fatal error, unless the flow rate exceeds 75 lpm and disables the
hose. In this instance a service agent should be called to inspect the LPG system.
The default setting for this is 60 lpm and the editing range is 0 - 60.
Press
F
to edit this value.
Press
F
to confirm the value or
to cancel.
C
L
MTR CAL
FP1
C
L
MTR CAL*
29.98
C
L
MTR CAL
.9051
C
L
XS FLOW*
60
L
MTR SIDE
1 SET
MTR SIDE
L
Note: Ensure the security switch on the meter is set to OFF before
entering the value.
Navigate to the MTR CAL using
2
and
8
keys.
Use
4
and
6
to toggle between fuel points.
Press
F
to set the required fuel point to edit mode.
Enter the uncompensated value from the test meter into the Litres
display window.
Press
F
to confirm the value or
to cancel.
If successful the dispenser will return a calculated correction factor. These changes may
take time to process.
15.8.5 Meter Side - MTR SIDE
This option is used to change the address of an LPG meter. Because the
LPG meters share a common bus, any meters NOT being edited must first
be disconnected.
Navigate to the MTR SIDE using
2
and
8
keys.
Press
F
to assign the LPG meter to the currently selected side.
* indicates in progress, success shows “1 SET” or “2 SET”.
A new address will be assigned automatically to the connected meter.
Repeat this process to assign an address to the remaining meter
15.8.4 Meter Calibrate - MTR CAL
After completing the test delivery for the Trade Measurement Verification this option is
used to enter the uncompensated value from the test meter in order to calibrate the LPG
meter.
$
$
$
$
$
$
Version 1.20