29
The mixing process using the UNGUATOR
®
e/s
To remove the UNGUATOR
®
Mixing System, first screw off the UNGUATOR
®
Jar Lid.
The UNGUATOR
®
Mixing System is then removed from the bayonet receptor by twisting
the UNGUATOR
®
MB shaft counterclockwise. Then the UNGUATOR
®
Mixing System
can be removed by pulling it downwards.
3.2
Operating Mode “HAND“
The pre-prepared UNGUATOR
®
Mixing System is inserted into the bayonet receptor
of the UNGUATOR
®
e/s from below and pushed up as far as it will go. The
UNGUATOR
®
Jar Lid and the UNGUATOR
®
Jar housing should both be held in one
hand simultaneously.
The bayonet receptor will grip immediately when the UNGUATOR
®
e/s is switched on
using the “Start/Stop” button. It will now run from the first revolution until the mixing
process is complete. The programmed mixing time will be completed at the set speed
step. The mixing time and speed parameters can also be changed during the mixing
process.
We recommend moving the UNGUATOR
®
Jar up and down steadily from the stop on
the UNGUATOR
®
Jar bottom to the stop on the UNGUATOR
®
Jar Lid every second,
while holding the UNGUATOR
®
Mixing System tightly with at least one hand.
The UNGUATOR
®
Mixing System can be switched to freespin as a special step with
manual stroke movement. Press the “Start/Stop” before the mixing process is complete
to switch to freespin. This will interrupt the mixing process, and the display will prompt
for freespin by showing “FSPA”.
The UNGUATOR
®
Mixing System needs to be removed from the UNGUATOR
®
e/s
and the UNGUATOR
®
Jar Lid slightly untwisted as if for air diminuation. The
UNGUATOR
®
Jar bottom is then pushed into the full down position using the
UNGUATOR
®
MB. Then the UNGUATOR
®
Jar Lid is retightened. The UNGU-
ATOR
®
Mixing System should now be inserted back into the bayonet receptor of the
UNGUATOR
®
e/s from below and pushed up as far as it will go. Now push the “Start/
Stop” button again, and the UNGUATOR
®
MB can now clean itself by means of high-
speed rotation in a position close to the lid. This is referred to as freespin. Most of the
ointment is removed from the UNGUATOR
®
MB and the mixing process is complete.
The display will show the total mixing time incl. the reset times after the freespin is
finished.
Summary of Contents for Unguator e/s
Page 1: ......
Page 2: ......
Page 47: ...47 12 Dokumentationsblatt ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ......
Page 52: ...GAKO International GmbH Dantestrasse 27 D 80637 München www unguator com T100A521 0708 ...