64
When you activate the switch, the direction setting of
the switch is displayed. Select the switch ON / OFF
direction (NORM / REV) with the [ /+] or [ /-] key.
When Battery Fail Safe is enabled, items for setting the
throttle servo position are displayed. The setting method
is the same as "Stick sw", so please refer to this section
of the manual for information on setting this function.
When turning on / off governor with switch
Select the ON / OFF switch channel with "GOV sw channel" on "SBUS BASIC"
menu.
Setting the switch to the ON position turns on, or enables the governor. The fol-
lowing describes this operation.
• Switch set to on position and engine running at 60% or
more of set speed
ON
• Throttle stick set to maximum slow position
ON
• Switch set to off position
OFF
(7) ON/OFF sw.: Governor on/off switch
This parameter allows the user to turn the governor on or off via a switch
on the transmitter. Pressing the [ /+] or [ /-] key activates the function.
Choose INH if you do not want to use it.
Governor can be turned
on and off by a switch.
(8) BAT F/S: Battery fail safe
When the receiver battery voltage becomes equal to or less than "BFS.
Volt" set in the "GOV EXPERT" menu, the battery fail safe function is ac-
tivated, the governor function is turned OFF, and the throttle servo moves
to the set position.
When the setting is
completed, the "!"
Mark is displayed.
If the battery voltage is lower than the set voltage of the
"
Battery
F/S
"
for about 3 seconds, the Gx (gyro) LED of the CGY solid red
light. When
"
Battery F/S
"
is set to
"
ACT
"
in
"
GOV BASIC
"
, the servo
is fixed to the throttle position set by
"
Battery F/S
"
. When the throt-
tle stick is set to the slowest position, the
"
Battery F/S
"
function is
temporarily canceled. However, after 30 seconds, the
"
Battery F/S
"
function is activated again and the servo is locked. When the
"
Bat-
tery F/S
"
operates, quickly landing and stopping the helicopter,
please charge the battery.