52
(14) Pit.
High: Pitch high memorizing
This parameter saves the full positive collective pitch point into the
CGY. Move the cursor to "Pit. High" by pressing the
[ /+]
or [ /-] key.
Press the [Enter] key to enter the setting mode. "EXECUTE: Enter (1
sec)" is displayed. Move the collective pitch stick to full positive pitch
and pressing the [Enter] key for about 1 second. The full positive pitch
signal will be saved to the CGY.
(15) Pit. Zero: Pitch zero memorizing
This parameter saves the zero collective pitch point into the CGY. Move
the cursor to "Pit. Zero" by pressing the
[ /+]
or [ /-] key. Press the [Enter]
key to enter the setting mode. "EXECUTE: Enter (1 sec)" is displayed.
Move the collective pitch stick to 0 degree pitch and pressing the [Enter]
key for about 1 second. The zero pitch signal will be saved to the CGY.
(16) Pit. Low: Pitch low memorizing
This parameter saves the full negative collective pitch point into the
CGY. Move the cursor to "Pit. Low" by pressing the
[ /+]
or [ /-] key.
Press the [Enter] key to enter the setting mode. "EXECUTE: Enter (1
sec)" is displayed. Move the collective pitch stick to full negative pitch
and pressing the [Enter] key for about 1 second. The full negative pitch
signal will be saved to the CGY.
Go to the menu title of
SWH BASIC screen 1/5
Summary of Contents for CGY755
Page 112: ......