43
Go to the menu title of
SBUS BASIC screen 1/3
(14) RESET: S.BUS data reset
This resets the S.BUS channel assignments back to the
defaults. Move the cursor to "RESET" by pressing the [
/+] or [ /-] key, and press the [Enter] key to enter the reset
mode. When "EXECUTE: Enter (1 sec)" is displayed, press
and hold the [Enter] key for about 1 second to initialize S.BUS
channel setting. If you do not wish to reset to the default set-
tings, press [Enter] key or [Esc/Page] key to exit reset mode.
(13) ELE2 channel Servo Type
(If you want to use the ELE2 port for purposes other than swash.)
This selects the ELE2 servo types. There are three types of the servo
driving frequency selection, AN:70
Hz, DG285 Hz, and 760 μS. All Futaba
digital servos can be operated with fastest DG:285 Hz mode but some
of other brands of servos do not support DG:285 Hz mode. In this case,
select the proper servo driving frequency per the manufacturer’s speci-
fications. Move the cursor to "Servo Type" by pressing the [ /+] or [ /-]
key and press the [Enter] key to enter the setting mode. Then select the
servo type with the [ /+] or [ /-] key. When "EXECUTE: Enter (1 sec)" is
displayed, press the [Enter] key for about 1 second. This changes the se-
lected type and exits the setting mode.
If you select H4-00 or H4-45 with 4 servo swashes, cannot set this ELE2
port servo type. In that case, select all swash servo types in SWH basic
servo type.
Setting: AN:70 Hz / DG:760 μS / DG:285 Hz
Initial setting: DG:285 Hz
WARNING
The servo type parameter within the CGY must match the type of
servo you are using. Incorrect setting may damage the CGY or the
servo. Incorrect setting may also result in a loss of control during
flight.