Fujitsu SPARC Enterprise M4000 Reference Manual Download Page 395

showssh(8)

System Administration

463

NAME

showssh - display the status, host public keys, fingerprint, or user public keys of the
SSH service configured for the XSCF network

SYNOPSIS

showssh

[

-c

hostkey

] [

-M

]

showssh

-c

pubkey

[

-u

user_name] [

-M

]

showssh

-h

DESCRIPTION

showssh

(8) command displays the status, host public keys, fingerprint, or user

public keys of the SSH service configured for the XSCF network.

The following information is displayed:

When specified the display of user public key, the user public key number, which
automatically numbered by system, and the user public key are displayed.

Only SSH2 is supported for XSCF.

Privileges

You must have one of the following privileges to run this command:

To display the user public key of other user account:

useradm

To display the information other than above:

useradm

,

platadm

,

platop

,

auditadm

,

auditop

,

domainadm

,

domainmgr

,

domainop

,

fieldeng

Refer to

setprivileges

(8) for more information.

OPTIONS

The following options are supported:

SSH status

Validity of the SSH service

RSA key

Host public key in RSA format

DSA key

Host public key in DSA format

Fingerprint

Host public key in fingerprint format

-c hostkey

Displays a host public key. If the

-c

option is omitted, "

-c

hostkey

" is assumed specified.

-c pubkey

Displays the user public key. If the

-c

option is omitted, "

-c

hostkey

" is assumed specified

Summary of Contents for SPARC Enterprise M4000

Page 1: ......

Page 2: ......

Page 3: ...SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF Reference Manual XSCF Control Package XCP 106x Part No 819 7891 12 November 2007 Revision A Manual Code C120 E333 05EN ...

Page 4: ...u and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and...

Page 5: ...marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems Inc SPARC64 est une marques déposée de SPARC International Inc utilisée sous le permis par Fujitsu Microelectronics Inc et Fujitsu Limi...

Page 6: ......

Page 7: ...ense 14 addfru 16 adduser 18 applynetwork 22 cfgdevice 28 console 34 clockboard 38 deleteboard 40 deletecodlicense 44 deletefru 48 deleteuser 50 disableuser 52 enableuser 54 exit 56 flashupdate 58 fmadm 62 fmdump 66 fmstat 74 getflashimage 80 ioxadm 86 ...

Page 8: ...setdateoffset 138 sendbreak 140 setaltitude 142 setarchiving 146 setaudit 152 setautologout 158 setcod 160 setdate 164 setdcl 168 setdomainmode 174 setdomparam 180 setdscp 184 setdualpowerfeed 190 setemailreport 194 sethostname 198 sethttps 202 setldap 208 setlocale 212 setlocator 214 setlookup 218 setnameserver 220 setnetwork 224 setntp 230 setpasswordpolicy 234 ...

Page 9: ...setupfru 294 setupplatform 298 showaltitude 304 showarchiving 306 showaudit 310 showautologout 316 showboards 318 showcod 324 showcodlicense 328 showcodusage 332 showconsolepath 338 showdate 342 showdcl 346 showdevices 354 showdomainmode 360 showdomainstatus 364 showdscp 368 showdualpowerfeed 374 showemailreport 376 showenvironment 378 showfru 384 showhardconf 388 showhostname 394 ...

Page 10: ...8 shownetwork 430 shownotice 436 showntp 438 showpasswordpolicy 442 showpowerupdelay 444 showresult 446 showroute 448 showshutdowndelay 452 showsmtp 454 showsnmp 456 showsnmpusm 460 showsnmpvacm 462 showssh 464 showstatus 468 showtelnet 472 showtimezone 474 showuser 480 snapshot 484 switchscf 492 testsb 496 unlockmaintenance 502 version 506 viewaudit 510 who 518 ...

Page 11: ... the point which you can t understand or would like to check on while using XSCF shell command Instead of reading from the start as you do so when reading a tutorial it is recommended to use this manual as you come across a point you would like to check on The description of XSCF shell command written in this manual is the same as the manual page which appears as a result of man command executed i...

Page 12: ...d to as XSCF user The XSCF user is required to have the following knowledge SolarisTM Operating System and Unix command SPARC Enterprise M4000 M5000 M8000 M9000 servers and basic knowledge of XSCF Notation of This Manual Here describes the notation used in this manual Intro 8 provides the XSCF shell commands and the brief description of them in the alphabetical order ...

Page 13: ...an t be omitted Braces The OPTIONS or OPERANDS enclosed in these braces are treated as a unit Separator You should specify one of the OPTIONS or OPERANDS delimited with this symbol Ellipsis You can specify multiple OPTIONS or OPERANDS just before DESCRIPTION This section gives the detailed description such as the command function It describes the behavior after the command executed and the content...

Page 14: ...execution EXIT STATUS This section gives the status which shows whether or not the command executed normally terminated 0 for normal termination and 0 for abnormal termination SEE ALSO This section gives the related command names Book Titles Manual Codes SPARC Enterprise M4000 M5000 Servers Site Planning Guide C120 H015 SPARC Enterprise M8000 M9000 Servers Site Planning Guide C120 H014 SPARC Enter...

Page 15: ...ers Service Manual C120 E330 External I O Expansion Unit Installation and Service Manual C120 E329 SPARC Enterprise M4000 M5000 M8000 M9000 Servers RCI Build Procedure C120 E361 SPARC Enterprise M4000 M5000 M8000 M9000 Servers Administration Guide C120 E331 SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF User s Guide C120 E332 SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF Reference M...

Page 16: ... disk Remote maintenance Service 4 Provided in system Man page of the XSCF Note The man page can be referenced on the XSCF Shell and it provides the same content as the SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF Reference Manual 5 Documentations and Supporting on the Web The latest information about other documents and the supporting of the SPARC Enterprise series are provided on the we...

Page 17: ...Fault Management MIB SUN FM MIB definition file http src opensolaris org source xref innv onnv gate usr src lib fm libfmd_snmp mibs d Solaris Operating System Related Manuals http docs sun com 6 Provided in firmware program CD For maintenance service for FEs a Firmware program file XSCF Control Package XCP file b XSCF extension MIB definition file 7 Information on Using the RCI function The manual...

Page 18: ...vers Overview Guide Service Manual SPARC Enterprise M4000 M5000 Servers Service Manual SPARC Enterprise M8000 M9000 Servers Service Manual Installation Guide SPARC Enterprise M4000 M5000 Servers Installation Guide SPARC Enterprise M8000 M9000 Servers Installation Guide Administration Guide SPARC Enterprise M4000 M5000 M8000 M9000 Servers Administration Guide XSCF User s Guide SPARC Enterprise M400...

Page 19: ...the information of the license see Appendix E Software License Condition in SPARC Enterprise M4000 M5000 M8000 M9000 Servers XSCF User s Guide Server class Model name Midrange SPARC Enterprise M4000 SPARC Enterprise M5000 High end SPARC Enterprise M8000 SPARC Enterprise M9000 Shell Prompt Notations XSCF XSCF C shell machine name C shell super user machine name Bourne shell and Korn shell Bourne sh...

Page 20: ...F Reference Manual November 2007 Fujitsu Welcomes Your Comments We would appreciate your comments and suggestions to improve this document You can submit your comments by using Reader s Comment Form on page xv ...

Page 21: ...Preface xv Reader s Comment Form ...

Page 22: ...BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 741 SUNNYVALE CA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES POSTAGE WILL BE PAID BY ADDRESSEE FUJITSU COMPUTER SYSTEMS ATTENTION ENGINEERING OPS M S 249 1250 EAST ARQUES AVENUE P O BOX 3470 SUNNYVALE CA 94088 3470 ...

Page 23: ...device connect a DVD TAPE drive to the port disconnect it from the port or display the status of the drive clockboard set or display the clock control unit used at system startup console connect to a domain console deleteboard disconnect an eXtended System Board XSB from the domain configuration deletecodlicense remove a Capacity on Demand COD right to use RTU license key from the COD license data...

Page 24: ... to the specified domain setaltitude set the altitude of the system setarchiving configure the log archiving functionality setaudit manage the system auditing functionality setautologout set the session timeout time of the XSCF shell setcod set up the Capacity on Demand COD resources used for domains setdate set the date and time of XSCF setdcl set a domain component list DCL setdomainmode set a d...

Page 25: ...cified domain setaltitude set the altitude of the system setarchiving configure the log archiving functionality setaudit manage the system auditing functionality setautologout set the session timeout time of the XSCF shell setcod set up the Capacity on Demand COD resources used for domains setdate set the date and time of XSCF setdcl set a domain component list DCL setdomainmode set a domain mode ...

Page 26: ...rivileges assign user privileges setroute set routing information for an XSCF network interface setshutdowndelay set the shutdown wait time at power interruption of the uninterruptible power supply UPS setsmtp set up the SMTP settings setsnmp manage the SNMP agent setsnmpusm specify the SNMPv3 agent s User based Security Model USM configuration setsnmpvacm modify the SNMPv3 agent s View based Acce...

Page 27: ...wdomainstatus display the current domain component list DCL showdscp display the IP addresses assigned to the Domain to Service Processor Communications Protocol DSCP showdualpowerfeed display the current setting of dual power feed mode showemailreport display the email report configuration data showenvironment display the intake air temperature and humidity temperature sensor information voltage ...

Page 28: ... showresult display the exit status of the most recently executed command showroute display routing information for an XSCF network interface showshutdowndelay show the shutdown wait time at power interruption of the uninterruptible power supply UPS showsmtp display the SMTP configuration information showsnmp display the configuration information and current status of the SNMP agent showsnmpusm di...

Page 29: ...XSCF unit between the active and standby states testsb perform an initial diagnosis of the specified physical system board PSB unlockmaintenance forcibly release the locked status of XSCF version display firmware version viewaudit display audit records who display a list of the user accounts who are logged in to the XSCF ...

Page 30: ...Intro 8 8 XSCF Reference Manual Last Revised June 2006 ...

Page 31: ...ssed from the operating system assign Assigns an XSB to the specified domain The assigned XSB is reserved for the specified domain and cannot be configured in or assigned to other domains The assigned XSB is configured in the domain by reboot or execution of the addboard 8 command with c configure reserve Reserves incorporation of an XSB into the domain configuration The action of reserve is the s...

Page 32: ...or power off processing the busy status is returned After that processing in the domain is completed reexecute the command f Forcibly incorporates into a domain an XSB Note If the f option is used to forcibly add a system board to a domain all the added hardware resources may not work normally For this reason use of the f option is not recommended in normal operation If the f option must be specif...

Page 33: ...0 01 0 02 0 and 03 0 forcibly into domain ID 2 EXIT STATUS The following exit values are returned SEE ALSO deleteboard 8 moveboard 8 replacefru 8 setdcl 8 setdomainmode 8 setupfru 8 showboards 8 showdcl 8 showdevices 8 showdomainstatus 8 showfru 8 testsb 8 XSCF addboard y c assign d 0 00 0 01 0 02 0 03 0 XSCF addboard f d 2 00 0 01 0 02 0 03 0 0 Successful completion 0 An error occurred ...

Page 34: ...addboard 8 12 XSCF Reference Manual Last Revised January 2007 ...

Page 35: ...our sales representative For details on COD RTU license keys refer to the COD documentation for your server Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported OPERANDS The following operands are supported EXAMPLES EXAMPLE 1 Adding a COD RTU License Key EXIT STATUS The following exit values are retu...

Page 36: ...addcodlicense 8 14 XSCF Reference Manual Last Revised June 2007 ...

Page 37: ... using menus The following FRUs can be added by the addfru 8 command CPU memory unit CMU I O unit IOU Fan unit FANU Power supply unit PSU Privileges You must have fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXIT STATUS The following exit values are returned SEE ALSO deletefru 8 replacefru 8 setupfru 8 showfru 8 sho...

Page 38: ...addfru 8 16 XSCF Reference Manual Last Revised January 2007 ...

Page 39: ...data the user name and UID if specified must not already be in use either locally or in LDAP When a user is created adduser 8 command stores the current password policy values in a file for the user For more information on setting password policy see setpasswordpolicy 8 Privileges You must have useradm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The followi...

Page 40: ...LE 1 Creating a New User EXIT STATUS The following exit values are returned SEE ALSO deleteuser 8 disableuser 8 enableuser 8 password 8 setldap 8 setpasswordpolicy 8 showldap 8 showpasswordpolicy 8 showuser 8 XSCF adduser u 359 jsmith 0 Successful completion 0 An error occurred ...

Page 41: ...e rebootxscf 8 command to reset XSCF to complete the setting Note If XSCF is reset without executing the applynetwork 8 command network information that is set is not reflected in XSCF Also information that is set is deleted Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION ...

Page 42: ...faces if any of these setting items omitted it results in errors To specify a host name use the sethostname 8 command To specify an IP address and net mask use the setnetwork 8 command To specify routing use the setroute 8 command EXAMPLES EXAMPLE 1 Reflects the information that has been set for the XSCF network On a midrange server XSCF applynetwork The following network settings will be applied ...

Page 43: ... 0 0 0 0 m 0 0 0 0 g 10 24 144 1 interface xscf 0 lan 1 status down IP address netmask route interface xscf 0 if status down IP address 10 24 100 1 netmask route interface lan 0 status down IP address netmask route interface xscf 1 lan 0 status up IP address 10 24 144 215 netmask 255 255 255 0 route n 0 0 0 0 m 0 0 0 0 g 10 24 144 1 interface xscf 1 lan 1 status down IP address netmask route inter...

Page 44: ...8 setnetwork 8 setroute 8 XSCF applynetwork y The following network settings will be applied xscf 0 hostname hostname 0 DNS domain name example com nameserver 10 23 4 3 interface xscf 0 lan 0 status up IP address 10 24 144 214 netmask 255 255 255 0 route n 0 0 0 0 m 0 0 0 0 g 10 24 144 1 interface xscf 0 lan 1 status down IP address netmask route Continue y n y Please reset the XSCF by rebootxscf ...

Page 45: ...nects the CD RW DVD RW drive unit and the tape drive unit hereafter collectively called the DVD drive tape drive unit to the specified port disconnects it from the domain or displays the current status of the DVD drive tape drive unit To connect the DVD drive tape drive unit the port number which is a PCI slot number on the I O unit which installed IOU Onboard Device Card A IOUA needs to specify E...

Page 46: ...nected to the DVD drive tape drive unit It is displayed in the IOU number PCI slot number format IOU SAS status Connection status between IOUA and built in switching unit It is changed by specifying attach or detach enable disable Setting status of the cfgdeive 8 command enable Connected with c attach disable Not connected up down Logical connection between IOUA and built in switching unit up Conn...

Page 47: ...ected DVD drive tape drive unit The DVD tape connection is maintained even if the domain power is turned off or the system is rebooted c attach Connects the DVD drive tape drive unit to the specified port c detach Disconnects the DVD drive tape drive unit from the specified port h Displays usage statement When used with other options or operands an error occurs l Displays the current status of the...

Page 48: ...ive unit from the port 0 0 XSCF cfgdevice l Current connection for DVD DAT Main chassis port 0 0 Expansion chassis port 8 0 Expander status Port No IOU SAS status SAS status 0 0 enable up enable up 0 2 disable down enable up 0 4 disable down enable up 0 6 disable down enable up 1 0 disable down enable up 1 2 disable down enable up 1 4 disable down enable up 1 6 disable down enable up 2 0 disable d...

Page 49: ...tion for DVD DAT port 0 0 Expander status Port No IOU SAS status SAS status 0 0 enable up enable up 0 2 disable down enable up XSCF cfgdevice l Current connection for DVD DAT port 0 0 Expander status Port No IOU SAS status SAS status 0 0 enable up enable up 0 2 disable down enable up 0 4 disable down enable up 0 6 disable down enable up 1 0 disable down enable up 1 2 disable down enable up 1 4 dis...

Page 50: ...cfgdevice 8 32 XSCF Reference Manual Last Revised June 2007 ...

Page 51: ...ain console and return to the XSCF shell console press the Enter key and then enter Note The console 8 command does not automatically log out the domain command line Make certain to log out from the domain prior to exiting the console Privileges You must have one of the following privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supporte...

Page 52: ...splay information on the currently connected domain console use the showconsolepath 8 command EXIT STATUS The following exit values are returned SEE ALSO sendbreak 8 showconsolepath 8 n Automatically answers n no to all prompts q Suppresses all messages to stdout including prompts r Sets up a connection to a read only console s escapeChar Specifies an escape character The default is sharp The char...

Page 53: ...displayed The clockboard 8 command is valid only for high end server Privileges You must have fieldeng privilege to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Displays the clock control unit that is currently used and the one used at the next system startup EXAMPLE 2 Specifies the clock control unit used at the next...

Page 54: ...clockboard 8 38 XSCF Reference Manual Last Revised June 2007 ...

Page 55: ...isconnects the XSB from the domain configuration but keeps it assigned Because the XSB thus remains assigned to the domain configuration it can be configured again in the domain by reboot the domain or execution of the addboard 8 command unassign Completely disconnects the XSB from the main configuration and puts it in the system board pool The XSB in the system board pool can be incorporated into...

Page 56: ...n is omitted c disconnect is used f Forcibly detaches the specified XSB Note If the f option is used to forcibly add a system board to a domain all the added hardware resources may not work normally For this reason use of the f option is not recommended in normal operation If the f option must be specified verify the status of every added system board and device h Displays usage statement When use...

Page 57: ...ss the command results in an error When the XSB is disconnected the hardware resource on the XSB is disconnected from the operating system For this reason command execution may take time The state in which an XSB has been assigned means that configuring the XSB in the specified domain has been reserved The reserved XSB is configured when the domain is rebooted or the addboard 8 command is executed...

Page 58: ...deleteboard 8 42 XSCF Reference Manual Last Revised January 2007 ...

Page 59: ...D RTU license database If you still want to delete the COD RTU license key you must reduce the number of COD CPUs in use Power off the appropriate number of domains or disconnect the appropriate number of boards Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported OPERANDS The following operands ar...

Page 60: ...deletecodlicense 8 44 XSCF Reference Manual Last Revised June 2007 SEE ALSO addcodlicense 8 setcod 8 showcod 8 showcodlicense 8 showcodusage 8 ...

Page 61: ...nd removing FRUs interactively using menus The following FRUs can be deleted CPU memory unit CMU I O unit IOU Privileges You must have fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXIT STATUS The following exit values are returned SEE ALSO addfru 8 deleteboard 8 replacefru 8 setupfru 8 showdomainstatus 8 showfru 8 s...

Page 62: ...deletefru 8 48 XSCF Reference Manual Last Revised January 2007 ...

Page 63: ...stem and they cannot log back in You cannot delete your own account Privileges You must have useradm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported OPERANDS The following operands are supported EXAMPLES EXAMPLE 1 Deleting a User EXIT STATUS The following exit values are returned SEE ALSO adduser 8 disableuser 8 enableuser 8 h ...

Page 64: ...deleteuser 8 50 XSCF Reference Manual Last Revised January 2007 ...

Page 65: ...ns on the system This includes password and SSH keys You can reenable a disabled account using enableuser 8 Privileges You must have useradm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported OPERANDS The following operands are supported EXAMPLES EXAMPLE 1 Disabling a User Account EXIT STATUS The following exit values are returned...

Page 66: ...disableuser 8 52 XSCF Reference Manual Last Revised January 2007 ...

Page 67: ...ust have useradm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported OPERANDS The following operands are supported EXAMPLES EXAMPLE 1 Enable a User Account EXIT STATUS The following exit values are returned SEE ALSO adduser 8 deleteuser 8 disableuser 8 showuser 8 h Displays usage statement When used with other options or operands a...

Page 68: ...enableuser 8 54 XSCF Reference Manual Last Revised January 2007 ...

Page 69: ...stration 55 NAME exit exit the XSCF shell SYNOPSIS exit DESCRIPTION The exit 1 command exits and closes the XSCF shell Privileges No privileges are required to run this command Refer to setprivileges 8 for more information ...

Page 70: ...exit 1 56 XSCF Reference Manual Last Revised January 2007 ...

Page 71: ...ivileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported c check Checks whether the specified firmware can be updated c update Updates the specified firmware In case the XSCF unit is duplicated configuration updates the firmware of both XSCF units c sync Synchronizes the firmware versions of ...

Page 72: ...When there s a faulty FRU can t update the firmware Resolve the FRU fault then update EXAMPLES EXAMPLE 1 Check whether the entire firmware can be updated to version 1020 q Suppresses all messages to stdout including prompts s version Specifies a XCP comprehensive firmware version For version specify a major version minor version and micro version continuously The XCP version number appears as xyyz...

Page 73: ...download is started SCF 0 bank 1 XCP version 1020 last version 1010 Firmware Element ID 07 version 01010002 last version 01010001 XSCF download has been completed SCF 0 bank 1 XCP version 1020 last version 1010 Firmware Element ID 07 version 01010002 last version 01010001 XSCF update has been completed SCF 0 bank 1 XCP version 1020 last version 1010 XSCF update is started SCF 0 bank 0 XCP version ...

Page 74: ...flashupdate 8 60 XSCF Reference Manual Last Revised January 2007 ...

Page 75: ...e might ask you to use fmadm or one of the other fault management utilities to gather more information or perform additional tasks The documentation for fmdump 8 describes more about tools to observe fault management activities Privileges You must have platop platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported...

Page 76: ... exit values are returned SEE ALSO fmdump 8 fmstat 8 XSCF fmadm config MODULE VERSION STATUS DESCRIPTION case close 1 0 active Case Close Agent fmd self diagnosis 1 0 active Fault Manager Self Diagnosis sysevent transport 1 0 active SysEvent Transport Agent syslog msgs 1 0 active Syslog Messaging Agent 0 Successful completion 0 An error occurred ...

Page 77: ...ction by a human administrator or service technician or affects system behavior the Fault Manager also issues a human readable message This message provides a summary of the problem and a reference to the knowledge article on the specified website You can use the v and V options to expand the display from a single line summary to increased levels of detail for each event recorded in the log You ca...

Page 78: ...r occurs e Displays events from the fault management error log instead of the fault log The error log contains private telemetry information used by XSCF s automated diagnosis software This information is recorded to facilitate post mortem analysis of problems and event replay and should not be parsed or relied upon for the development of scripts and other tools f Displays only lines that have bee...

Page 79: ...rors that were associated with the diagnosis Time Format Description mm dd yy hh mm ss Month day year hour in 24 hour format minute and second Any amount of whitespace can separate the date and time The argument should be quoted so that the shell interprets the two strings as a single argument mm dd yy hh mm Month day year hour in 24 hour format and minute Any amount of whitespace can separate the...

Page 80: ... hh mm ss Hour in 24 hour format minute and second of the current day hh mm Hour in 24 hour format and minute of the current day Tns Tnsec T nanoseconds ago where T is an integer value specified in base 10 Tus Tusec T microseconds ago where T is an integer value specified in base 10 Tms Tmsec T milliseconds ago where T is an integer value specified in base 10 Ts Tsec T seconds ago where T is an in...

Page 81: ...19676f828515 LINUX 8000 1N Sep 06 15 42 56 6132 0f4b429f c048 47cd 9d9f a2f7b6d4c957 LINUX 8000 1N Sep 06 16 07 14 4652 7d5fb282 e01b 476a b7e1 1a0f8de80758 LINUX 8000 1N Sep 06 16 08 16 3755 41379237 9750 4fd6 bce3 b5131d864d34 LINUX 8000 1N Sep 29 14 49 27 8452 0455ceaa e226 424a 9b34 27603ca603f1 FMD 8000 58 Sep 29 15 02 00 3039 fb550ebc 80e9 41c8 8afc ac680b9eb613 FMD 8000 58 Sep 29 15 09 25 4...

Page 82: ...ed code FMD 8000 58 diag time 1128021009 615016 de embedded nvlist nvlist version 0 version 0x0 scheme fmd authority embedded nvlist nvlist version 0 version 0x0 product id SUNW SPARC Enterprise chassis id BF0000001V server id localhost end authority mod name sde mod version 1 13 end de fault list sz 0x1 fault list array of embedded nvlists start fault list 0 nvlist version 0 version 0x0 class fau...

Page 83: ...r examination by Sun IMPACT The fault log will need to be manually examined using fmdump 1M in order to determine if any human response is required MSG ID FMD 8000 11 TYPE Defect VER 1 SEVERITY Minor EVENT TIME Tue Nov 7 07 03 25 PST 2006 PLATFORM SUNW SPARC Enterprise CSN 7860000764 HOSTNAME san ff2 20 0 SOURCE sde REV 1 5 EVENT ID 2b03ab60 96db 439d a13a 2f420a1b73c7 DESC A Solaris Fault Manager...

Page 84: ...fmdump 8 72 XSCF Reference Manual Last Revised January 2007 ...

Page 85: ...ribe more about tools to observe fault management activities If the m option is present fmstat reports any statistics kept by the specified fault management module The module list can be obtained using fmadm config If the m option is not present fmstat reports the following statistics for each of its client modules module The name of the fault management module as reported by fmadm config ev_recv ...

Page 86: ...ror occurs m module Prints a report on the statistics associated with the specified fault management module instead of the default statistics report Modules can publish an arbitrary set of statistics to help service the fault management software itself If used without the a option displays only those statistics kept by the module If used with the a option displays statistics kept by the module and...

Page 87: ...save true save checkpoints for module fmd ckpttime 0d total checkpoint time fmd ckptzero false zeroed checkpoint at startup fmd debugdrop 4 dropped debug messages fmd dequeued 1 total events dequeued by module fmd dispatched 1 total events dispatched to module fmd dlastupdate 1144424838299131us hrtime of last event dequeue completion fmd dropped 0 total events dropped on queue overflow fmd dtime 0...

Page 88: ...fmdump 8 XSCF fmstat module ev_recv ev_acpt wait svc_t w b open solve memsz bufsz case close 0 0 0 0 0 0 0 0 0 0 0 0 fmd self diagnosis 1 1 0 0 0 2 0 0 1 0 27b 0 sysevent transport 0 0 0 0 573 2 0 0 0 0 0 0 syslog msgs 0 0 0 0 0 0 0 0 0 0 97b 0 XSCF fmstat z m fmd self diagnosis NAME VALUE DESCRIPTION module 1 error events received from fmd modules 0 Successful completion 0 An error occurred ...

Page 89: ...run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported d Deletes all previous firmware image files still on the XSCF unit then exits h Displays usage statement When used with other options or operands an error occurs l Lists firmware image files that are still on the XSCF unit then exits n Automatically answers n no to all prompts p proxy Specifi...

Page 90: ...formats for this value include the following http server port path file https server port path file ftp server port path file file media usb_msd path file where the value for file is in one of the following formats XCPvvvv tar gz FFXCPvvvv tar gz DCXCPvvvv tar gz and vvvv is the four character version number XSCF getflashimage http imageserver images FFXCP1041 tar gz Existing versions Version Size...

Page 91: ...ved 1MB received 2MB received 43MB received 44MB received 45MB received Download successful 46827KB at 1016 857KB s Checking file MD5 e619e6dd367c888507427e58cdb8e0a1 XSCF getflashimage p webproxy sun com 8080 http imageserver images FFXCP1041 tar gz Existing versions Version Size Date FFXCP1040 tar gz 46827123 Wed Mar 14 19 11 40 2007 Warning About to delete existing versions Continue y n y Remov...

Page 92: ...0 tar gz Password not echoed 0MB received 1MB received 2MB received 43MB received 44MB received 45MB received Download successful 46827KB at 1016 857KB s Checking file MD5 e619e6dd367c888507427e58cdb8e0a3 XSCF getflashimage file media usb_msd images FFXCP1041 tar gz Existing versions Version Size Date FFXCP1040 tar gz 46827123 Wed Mar 14 19 11 40 2007 Warning About to delete existing versions Cont...

Page 93: ...ied The target device can be a downlink card mounted in a built in PCI slot in the host system an External I O Expansion Unit or a field replaceable unit FRU in an External I O Expansion Unit The downlink card is identified by a string which identifies the host path to the card An uplink card is a FRU in the I O boat Privileges You must have one of the following privileges to run these commands Re...

Page 94: ...are supported M Displays text by page This option provides a function that is the same as that of the more command p Parsable output Suppresses headers in display output Fields are separated by single tabs v Specifies verbose output Refer to specific operands for details env elt target sensors ...

Page 95: ...d See EXAMPLE 2 The results are listed in tabular format Each FRU sensor is listed in the first column In the next column is the sensor name such as T_AMBIENT for ambient temperature or V_12V_0V for the voltage reading of the 12V rail The third fourth and fifth columns display the sensor reading Value sensor resolution Res and Units respectively See EXAMPLE 1 Each FRU can have a variety of differe...

Page 96: ...n is displayed See EXAMPLE 2 The results are listed in tabular format Each FRU sensor is listed in the first column In the next column is the sensor name such as T_AMBIENT for ambient temperature or V_12V_0V for the voltage reading of the 12V rail The third fourth and fifth columns display the sensor reading Value sensor resolution Res and Units respectively See EXAMPLE 1 Each FRU can have a varie...

Page 97: ... and chassis ACTIVE LED may be set to each state However the hardware frequently updates the LED state so changes to the LED state may not be visible Note Other LEDs are not under software control A list of LEDs present in the system can be displayed by using the env l operand list target Lists the External I O Expansion Units under system management If no target is specified list displays a list ...

Page 98: ... LEDs to indicate the FRU is ready to remove Must be used with the f option Be aware that using f can crash the domain Do not remove both power supply units PSUs in the same External I O Expansion Unit If both PSUs are powered down in this way then the External I O Expansion Unit cannot be turned back on from the command line It must be powered on physically Note When a power supply is powered off...

Page 99: ... are reset and re initialized If a box is specified the fan controller and demux in the box are reset and re initialized along with all bridge controllers associated with the External I O Expansion Unit setled on off slow fast target led_type Sets LED state off Off on On fast Fast blink slow Slow blink Refer to the entry for led_type in this section for detailed information about LED types target ...

Page 100: ... 0 PCI E slot0 The External I O Expansion Unit box_id is identified by serial number Use iox nnnn where nnnn represents the last four digits of the box serial number Some commands affect only a single component of an External I O Expansion Unit system For example individual boats and power supplies may be turned on and turned off independently A FRU in an External I O Expansion Unit fru is identif...

Page 101: ...5 PS1 V_12V_ANODE 11 762 0 059 V IOX A3B5 PS1 V_12V_CATHODE 11 762 0 059 V IOX A3B5 PS1 V_ISHARE 0 672 0 040 V IOX A3B5 PS1 I_DC 5 211 0 289 A IOX A3B5 PS1 S_FAN_ACTUAL 4115 854 49 588 RPM IOX A3B5 PS1 S_FAN_SET 4500 000 300 000 RPM IOX A3B5 IOB0 T_CHIP 32 000 1 000 C IOX A3B5 IOB0 T_HOTSPOT 35 000 1 000 C IOX A3B5 IOB1 T_CHIP 33 000 1 000 C IOX A3B5 IOB1 T_HOTSPOT 36 000 1 000 C IOX A3B5 IOB1 V_1...

Page 102: ...t Using Verbose Output EXAMPLE 6 Displaying a Downlink Card Using Hostpath in Verbose Mode With Headers Suppressed EXAMPLE 7 Powering On the Locator LED for Power Supply 0 in External I O Expan sion Unit 12B4 EXAMPLE 8 Displaying Locator LED Status for the External I O Expansion Unit If the FRU service indicator is already on due to a detected fault condition only the box locator LED will be set t...

Page 103: ...hassis white locator LED between off and fast If the push button is used to turn off the locator LED fast blink FRU service LEDs are cleared EXIT STATUS The following exit values are returned XSCF ioxadm locator on iox x031 ps1 XSCF ioxadm locator Location Sensor Value Resolution Units IOX X031 LOCATE Fast LED XSCF ioxadm env 1 iox x031 ps1 SERVICE Location Sensor Value Resolution Units IOX X031 P...

Page 104: ...ioxadm 8 96 XSCF Reference Manual Last Revised January 2007 ...

Page 105: ...that each can fit on one screen In such cases the following key operations are available If intro is specified for command_name a list of XSCF shell commands is displayed EXAMPLES EXAMPLE 1 Displays the manual page of the addboard 8 command EXAMPLE 2 Displays a list of XSCF shell commands h Displays usage statement When used with other options or operands an error occurs command_name Specifies the...

Page 106: ...man 1 98 XSCF Reference Manual Last Revised January 2007 EXIT STATUS The following exit values are returned 0 Successful completion 0 An error occurred ...

Page 107: ...g system assign Disconnects a configured XSB from its domain configuration and assigns it to the specified destination domain configuration The assigned XSB is reserved for the specified domain and cannot be configured in or assigned to other domains The assigned system board is configured in the domain by reboot the domain or execution of the addboard 8 command with c configure reserve Reserves d...

Page 108: ...mitted c configure is used d domain_id Specifies the ID of the destination domain in which an XSB is to be moved domain_id can be 0 23 depending on the system configuration f Forcibly detaches the specified XSB Note If the f option is used to forcibly remove the XSB from the source domain a serious problem may occur in a process bound to CPU or process accessing a device For this reason use of the...

Page 109: ...ing system of the source domain is running The source domain is powered off If c reserve is specified when either the domain power of the move source has been turned off or the operating system is not running the XSB is immediately disconnected from the domain of the move source and assigned to the domain of the move destination Moving the XSB involves the following internal operations and therefo...

Page 110: ...ment of the XSB 00 0 to the domain ID 1 EXIT STATUS The following exit values are returned SEE ALSO addboard 8 deleteboard 8 setdcl 8 setupfru 8 showboards 8 showdcl 8 showdevices 8 showdomainstatus 8 showfru 8 XSCF moveboard d 1 c reserve 00 0 0 Successful completion 0 An error occurred ...

Page 111: ...ed OPERANDS The following operand is supported EXAMPLES EXAMPLE 1 Displays the host whose host name is scf0 hostname0 EXIT STATUS The following exit values are returned Server DNS server name Address IP address of DNS server Name Specified host name Address IP address of the host name h Displays usage statement When used with other options or operands an error occurs hostname Specifies the host na...

Page 112: ...nslookup 8 108 XSCF Reference Manual Last Revised January 2007 ...

Page 113: ...current user account Caution When you change the password for another user by using the user operand the system password policy is not enforced The user operand is intended only for creating a new user s initial password or replacing a lost or forgotten password for a user account When changing another user s password be sure to choose a password that conforms with the system password policy You c...

Page 114: ...is 1 A value of 1 means that the account will not be locked after the password expires Valid values are integers with value of 1 or greater M maxdays Sets the maximum number of days that a password is valid This value is assigned to new user accounts when they are created The initial value is 999999 Valid values are integers with value of zero or greater n mindays Sets the minimum number of days b...

Page 115: ... Until February 2 2008 EXAMPLE 2 Set Password Lock 10 Days After Password Expiration EXIT STATUS The following exit values are returned SEE ALSO setpasswordpolicy 8 showpasswordpolicy 8 XSCF password e 2008 02 02 XSCF password i 10 0 Successful completion 0 An error occurred ...

Page 116: ...password 8 112 XSCF Reference Manual Last Revised November 2007 ...

Page 117: ...ecified options is displayed Enter y to execute the command or n to cancel the command platadm fieldeng Can run this command for all domains domainadm domainmgr Can run this command only for your managed domains a Turns off the power to all domains Only users who have the platadm and fieldeng privileges can specify this option d domain_id Specifies the ID of the domain to be turned off domain_id c...

Page 118: ...e displayed in the following format The showdomainstatus 8 command can be used to check whether the system power is off EXAMPLES EXAMPLE 1 Turns off power to all domains EXAMPLE 2 Turns off power to domains with domain IDs 0 Powered off The power was turned off normally Not Powering off An error occurred and the power could not be turned off An error message is displayed with Not Powering off XSCF...

Page 119: ...weroff d 1 DomainIDs to power off 01 Continue y n y 01 Not powering off Permission denied Note This command only issues the instruction to power off The result of the instruction can be checked by the showlogs power XSCF poweroff f d 0 DomainIDs to power off 00 The f option will cause domains to be immediately resets Continue y n y 00 Powering off Note This command only issues the instruction to p...

Page 120: ...els the poweroff 8 command execution that is in progress Automati cally replies with n without displaying the prompt EXIT STATUS The following exit values are returned SEE ALSO poweron 8 reset 8 showdomainstatus 8 XSCF poweroff q n d 3 0 Successful completion 0 An error occurred ...

Page 121: ...e command platadm fieldeng Can run this command for all domains domainadm domainmgr Can run this command only for your managed domains a Turns on the power to every domain that has been completely set up Only users who have the platadm or fieldeng privileges can specify this option The domain that has been completely set up means a domain that has been completely set up with the setdcl 8 and addbo...

Page 122: ... turned on normally Not Powering on An error occurred and the power could not be turned on An error message is displayed with Not Powering on XSCF poweron a DomainIDs to power on 00 01 02 03 Continue y n y 00 Powering on 01 Powering on 02 Powering on 03 Powering on Note This command only issues the instruction to power on The result of the instruction can be checked by the showlogs power XSCF powe...

Page 123: ...prompt EXAMPLE 7 Cancels the poweron 8 command execution that is in progress Automati cally replies with n without displaying the prompt EXIT STATUS The following exit values are returned SEE ALSO poweroff 8 reset 8 showdomainstatus 8 XSCF poweron d 1 DomainIDs to power on 01 Continue y n n XSCF poweron n d 1 DomainIDs to power on 01 Continue y n n XSCF poweron q n d 1 0 Successful completion 0 An...

Page 124: ...poweron 8 122 XSCF Reference Manual Last Revised January 2007 ...

Page 125: ...st have fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported OPERANDS The following operands are supported c Prints only the containers and their data This option does not print the FRU tree hierarchy h Displays usage statement When used with other options or operands an error occurs M Displays text by page This option pr...

Page 126: ...frutree chassis HDD0 Label HDD0 disk fru frutree chassis DVD Label DVD frutree chassis SCC Label SCC frutree chassis SCC Label SCC scc fru frutree chassis PCI0 Label PCI0 frutree chassis PCI1 Label PCI1 frutree chassis SCSIBP Label SCSIBP frutree chassis SCSIBP Label SCSIBP system board container frutree chassis PS0 Label PS0 frutree chassis PS0 Label PS0 power supply container frutree chassis C0 ...

Page 127: ...ta EXIT STATUS The following exit values are returned SEE ALSO ioxadm 8 XSCF prtfru l power supply frutree chassis PS0 Label PS0 power supply container XSCF prtfru l mem module frutree chassis C0 Label C0 system board P0 Label P0 cpu B0 Label B0 bank D0 Label D0 mem module container 0 Successful completion 0 An error occurred ...

Page 128: ...prtfru 8 126 XSCF Reference Manual Last Revised January 2007 ...

Page 129: ...f you perform this command the information that is set is not applied in XSCF EXAMPLES EXAMPLE 1 Resets the XSCF EXAMPLE 2 Resets the XSCF Automatically replies with y to the prompt EXAMPLE 3 Resets the XSCF Automatically replies with y without displaying the prompt EXAMPLE 4 Cancels the rebootxscf 8 command execution that is in progress h Displays usage statement When used with other options or o...

Page 130: ...otxscf 8 128 XSCF Reference Manual Last Revised June 2007 EXIT STATUS The following exit values are returned SEE ALSO applynetwork 8 setdate 8 sethttps 8 setssh 8 0 Successful completion 0 An error occurred ...

Page 131: ...fru 8 command CPU memory unit CMU I O unit IOU FAN unit FANU Power supply unit PSU XSCF unit XSCFU Privileges You must have fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXIT STATUS The following exit values are returned SEE ALSO addboard 8 addfru 8 deleteboard 8 deletefru 8 setupfru 8 showdcl 8 showdomainstatus 8 sh...

Page 132: ...replacefru 8 132 XSCF Reference Manual Last Revised January 2007 ...

Page 133: ... command Refer to setprivileges 8 for more information OPTIONS The following options are supported por Resets the domain system panic Instructs the domain operating system to generate a panic The command is ignored if it is issued during power off or shutdown xir Resets the domain CPU platadm fieldeng Can run this command for all domains domainadm domainmgr Can run this command only for your manag...

Page 134: ...nd EXAMPLES EXAMPLE 1 Causes a panic in domain ID 0 EXAMPLE 2 Resets the CPU in domain ID 0 Automatically answers y to all prompts EXAMPLE 3 Resets domain ID 0 Suppresses prompts and automatically answers y to all prompts level Specifies the level of resetting One of the following can be specified This operand cannot be omitted por Resets the domain system request Instructs the domain operating sy...

Page 135: ...eset command execution that is in progress EXIT STATUS The following exit values are returned SEE ALSO poweroff 8 poweron 8 setdomainmode 8 showdomainstatus 8 XSCF reset d 0 panic DomainID to panic 00 Continue y n n 0 Successful completion 0 An error occurred ...

Page 136: ...reset 8 136 XSCF Reference Manual Last Revised January 2007 ...

Page 137: ... or after the XSCF reset by using a command such as the rebootxscf 8 with the result that the time subtraction between XSCF and the domain remains stored The resetdateoffset 8 command resets the every time subtraction between XSCF and each domain which stored in XSCF As a result the time of domain after startup will be set to the same time as XSCF Privileges You must have platadm or fieldeng privi...

Page 138: ...resetdateoffset 8 138 XSCF Reference Manual Last Revised January 2007 ...

Page 139: ...this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXIT STATUS The following exit values are returned SEE ALSO console 8 showconsolepath 8 platadm Can run this command for all domains domainadm Can run this command only for your managed domains d domain_id Specifies only one ID of the domain to which to send the break signal domain_id can be 0 23...

Page 140: ...sendbreak 8 140 XSCF Reference Manual Last Revised June 2007 ...

Page 141: ...However even if no altitude is set for the system any abnormality in temperatures such as the CPU temperature can still be detected so the system would not be damaged by a fatal error When the showaltitude 8 command is executed the current settings are displayed EXAMPLES EXAMPLE 1 Sets the altitude of the system to 1000 m h Displays usage statement When used with other options or operands an error...

Page 142: ...XAMPLE 2 Sets the altitude of the system to 200 m The specified value is rounded up to the nearest hundred meters EXIT STATUS The following exit values are returned SEE ALSO showaltitude 8 XSCF setaltitude s altitude 157 200m 0 Successful completion 0 An error occurred ...

Page 143: ...rchiving allows the user to set up the Service Processor to automatically archive its log data on a remote host Note You must set up the archive host correctly prior to enabling the log archiving feature See EXAMPLE 1 If you attempt to enable archiving while the configuration is invalid for example if the specified archive host does not exist setarchiving exits with an error message setarchiving e...

Page 144: ...host key from the archive host using the SSH protocol If the t option is used setarchiving downloads the key from the host specified in the argument to t Otherwise setarchiving downloads the key from the current archive host Next setarchiving displays the key s md5 fingerprint and prompts you for confirmation of the identity of the host to continue If you accept the key it is saved and used for se...

Page 145: ...command displays an error and exits without making any changes n Automatically answers no to all prompts Prompts are displayed p password Sets the password used for ssh login This option is provided to facilitate scripting To change the password interactively use the r option r Reads the password used for ssh login The setarchiving command displays a prompt and reads the new password without echoi...

Page 146: ...Cannot be used with any options disable De activates the log archiving feature Cannot be used with any options XSCF setarchiving t jsmith somehost company com home jsmith logs r Enter ssh password for jsmith somehost company com XSCF setarchiving k download Downloading public host key from somehost company com Fingerprint c3 75 f9 97 7d dc le le 62 06 c1 6f 87 bc e8 0d Accept this public key yes n...

Page 147: ...manages the collection of data on the use of system resources Audit data provides a record of security related system events This data can be used to assign responsibility for actions that have taken place on the system Auditing generates records when specified events occur Events that generate audit records include System startup and shutdown Login and logout Authentication actions Administrative...

Page 148: ...he ACS_ prefix may be omitted For example the class of audit related events can be expressed as ACS_AUDIT AUDIT or 16 The following are valid classes all Denotes all classes ACS_SYSTEM 1 System related events ACS_WRITE 2 Commands that can modify a state ACS_READ 4 Commands that read a current state ACS_LOGIN 8 Login related events ACS_AUDIT 16 Audit related events ACS_DOMAIN 32 Domain management r...

Page 149: ...e global user audit record generation policy g enable disable Sets the global user audit record generation policy When set to disable no audit record which can be attributed to any user account is generated These settings can be overridden on an individual user basis using the a option h Displays usage statement When used with other options or operands an error occurs m mailaddr Sets the mail addr...

Page 150: ...50 and 75 respectively of the available storage for audit records is consumed The default value is 80 Warnings are issued as a message to the console and optionally to an administrator using email See m mailaddr archive Notifies the log archiving facility to archive the current audit trail delete Delete the portion of the local audit trail in the secondary partition This can be used to free space ...

Page 151: ...AMPLE 4 Enabling Auditing Turns on writing of the audit records for the audit trail EXAMPLE 5 Enabling Warnings Warnings will be sent at 50 capacity and 75 capacity EXIT STATUS The following exit values are returned SEE ALSO showaudit 8 XSCF setaudit enable XSCF setaudit t 50 75 0 Successful completion 0 An error occurred ...

Page 152: ...setaudit 8 156 XSCF Reference Manual Last Revised June 2007 ...

Page 153: ...S The following options are supported EXTENDED DESCRIPTION The specified session timeout time becomes effective after the subsequent login EXAMPLES EXAMPLE 1 Sets the session timeout time of the XSCF shell to 30 minutes EXIT STATUS The following exit values are returned SEE ALSO showautologout 8 h Displays usage statement When used with other options or operands an error occurs s timeout Specifies...

Page 154: ...setautologout 8 158 XSCF Reference Manual Last Revised January 2007 ...

Page 155: ...in_id is specified current values are displayed in the square brackets at the command prompt If no value is specified for an operand it retains its current value Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported d domain_id Domain identifier domain_id can be 0 23 depending on the system configur...

Page 156: ...ue is 4 proc rtus The number of Right To Use RTUs licenses reserved for a domain One RTU license is required for each CPU XSCF setcod PROC RTUs installed 0 PROC Headroom Quantity 0 to disable 4 MAX 0 1 WARNING Using headroom requires you to install license key s within 30 days Do you agree y n y PROC RTUs reserved for domain 0 1 MAX 0 PROC RTUs reserved for domain 1 0 MAX 0 PROC RTUs reserved for ...

Page 157: ...a message similar to this one in the XSCF console EXAMPLE 3 Set the COD Headroom CPUs to 0 EXIT STATUS The following exit values are returned SEE ALSO addcodlicense 8 showcod 8 codd 15 51 36 COD PROC Headroom changed to 3 XSCF setcod 0 0 Successful completion 0 An error occurred ...

Page 158: ...setcod 8 162 XSCF Reference Manual Last Revised June 2007 ...

Page 159: ...nit is duplicated configuration the setting automatically reflected to the standby XSCF When there is a defect on the standby XSCF it leads to an error and the setting will be reflected to the active XSCF only If the XSCF is used as an NTP server change the XSCF time and synchronize the domain times with the XSCF time The XSCF time is applied to a domain during either of the following operations h...

Page 160: ...e current time Automatically replies with y to the prompt EXAMPLE 4 Sets January 27 16 59 00 2006 of the local time JST as the current time Automatically replies with y without displaying the prompt EXIT STATUS The following exit values are returned XSCF setdate s 012716592006 00 Fri Jan 27 16 59 00 JST 2006 The XSCF will be reset Continue y n y Fri Jan 27 16 59 00 JST 2006 XSCF The reset continue...

Page 161: ...setdate 8 System Administration 165 SEE ALSO setntp 8 settimezone 8 showdate 8 showntp 8 showtimezone 8 ...

Page 162: ...setdate 8 166 XSCF Reference Manual Last Revised June 2007 ...

Page 163: ...a combination of a PSB number and the number of one partition of the partitioned PSB x is an integer ranging from 00 to 15 and y is an integer ranging from 0 to 3 The setdcl 8 command associates an XSB with an LSB that can be recognized by an operating system in the domain and its settings enable the operating system in the domain to use hardware resources on the associated XSB The setdcl 8 comman...

Page 164: ...cifies an LSB number An integer ranging from 0 to 15 can be specified xsb Specifies an XSB number The following xsb form is accepted x y x An integer from 00 15 y An integer from 0 3 lsb and xsb can be specified with an equal sign as a delimiter The space character must not be inserted immediately before and after lsb xsb can be repeated multiple times by using a space character as a delimiter If ...

Page 165: ... range applicable for a detected error during an initial diagnosis of hardware no mem Whether to omit the use of memory on a domain no io Whether to omit the use of I O devices on a domain float Whether to set a priority for the board as a floating board relative to other boards If policy is specified for option either of the following can be specified for value fru Degrades the target part for an...

Page 166: ...y Degradation range applicable for a detected error during an initial diagnosis of hardware no mem Whether to omit the use of memory on a domain no io Whether to omit the use of I O devices on a domain float Whether to set a priority for the board as a floating board relative to other boards If policy is specified for option either of the following can be specified for value fru Degrades the targe...

Page 167: ...d XSB 00 1 for LSB 01 of domain ID 0 EXAMPLE 2 Sets no mem true for LSB 00 and 01 of domain ID 0 EXAMPLE 3 Sets policy system for domain ID 0 If no io is specified for option either of the following can be specified for value true Omits the use of I O devices on a domain false Does not omit the use of I O devices on a domain default If float is specified for option either of the following can be s...

Page 168: ... the XSBs associated with LSB 00 and 01 of domain ID 0 EXIT STATUS The following exit values are returned SEE ALSO addboard 8 deleteboard 8 moveboard 8 setupfru 8 showboards 8 showdcl 8 showdevices 8 showfru 8 XSCF setdcl d 0 r 00 01 0 Successful completion 0 An error occurred ...

Page 169: ... and suppress break signal reception Secure Mode The default of the host watchdog is enable and suppress break signal reception is enable Whether to enable or disable the auto boot function used at domain startup Autoboot If the domain mode is set the current settings of the domain mode are listed Privileges You must have one of the following privileges to run this command Diagnostic level Secure ...

Page 170: ...ror occurs m function mode Sets the domain mode and specifies its values Use function to set the domain mode One of the following can be specified diag Specifies the OpenBoot PROM diagnostic level secure Specifies whether to enable or disable the host watchdog and suppress break signal reception autoboot Specifies whether to enable or disable the Auto boot function When diag is specified for funct...

Page 171: ... 4 The Auto boot function is enabled for domain ID 0 Suppresses prompts and automatically answers y to all prompts XSCF setdomainmode d 0 m diag none Diagnostic Level min none Secure Mode on Autoboot on The specified modes will be changed Continue y n y configured Diagnostic Level none Secure Mode on host watchdog available Break signal non receive Autoboot on autoboot on XSCF setdomainmode y d 0 ...

Page 172: ...setdomainmode 8 176 XSCF Reference Manual Last Revised June 2007 EXIT STATUS The following exit values are returned SEE ALSO showdomainmode 8 0 Successful completion 0 An error occurred ...

Page 173: ...owing options are supported use nvramrc Whether to execute the contents of the NVRAM at the boot or reboot of a domain security mode Firmware security level setting set defaults Whether to restore OpenBoot PROM environment variables to the settings at the time of shipment from the factory platadm Can run this command for all domains domainadm Can run this command only for your managed domain d dom...

Page 174: ... time of shipment from the factory Automatically re plies with y without displaying the prompt EXIT STATUS The following exit values are returned use nvramrc Sets false for theuse nvramrc environment variable security mode Sets none to the security mode environment variable set defaults Restores the OpenBoot PROM environment variables to the settings at the time of shipment from the factory XSCF s...

Page 175: ... DSCP link independently of all other DSCP address settings using the d domain_id and i address arguments You can set the IP address of the Service Processor independently of all other DSCP address settings using the s and i address arguments If DSCP has been previously configured the current settings are displayed If they are correct they can be accepted by pressing the Return key An error occurs...

Page 176: ...re out of range and address conflict errors and commits the new settings h Displays usage statement When used with other options or operands an error occurs i address Specifies an IP address in the IPv4 dotted decimal format When used with m netmask it specifies a network address for all DSCP links in the system When used with d domain_id it specifies an individual domain specific IP address for u...

Page 177: ...scp DSCP network 0 0 0 0 10 1 1 0 DSCP netmask 255 0 0 0 255 255 255 0 XSCF address 10 1 1 1 ENTER Domain 00 address 10 1 1 2 ENTER Domain 01 address 10 1 1 3 ENTER Domain 02 address 10 1 1 4 ENTER Domain 03 address 10 1 1 5 ENTER Domain 04 address 10 1 1 6 ENTER Domain 05 address 10 1 1 7 ENTER Domain 06 address 10 1 1 8 ENTER Domain 07 address 10 1 1 9 ENTER Domain 08 address 10 1 1 10 ENTER Dom...

Page 178: ...setdscp 8 186 XSCF Reference Manual Last Revised January 2007 EXIT STATUS The following exit values are returned SEE ALSO showdscp 8 0 Successful completion 0 An error occurred ...

Page 179: ...d is displayed Privileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION The state of the current dual power feed mode can be checked by using the showdualpowerfeed 8 command EXAMPLES EXAMPLE 1 Disables dual power feed mode in the system Before rebooting the sys tem a me...

Page 180: ...in the system Before rebooting the system a message is displayed EXIT STATUS The following exit values are returned SEE ALSO showdualpowerfeed 8 XSCF setdualpowerfeed s enable disable enable NOTE Dual power feed will be enabled the next time the platform is powered on 0 Successful completion 0 An error occurred ...

Page 181: ...red If you run the setemailreport command without specifying any options you will be prompted to answer whether email reporting is to be enabled If enabled you will be prompted to provided a list of email addresses Where You can set up email reporting noninteractively by using the s option After the email server and port have been set up using setsmtp 8 you can use setemailreport t to send a test ...

Page 182: ...d entries for variable are enable recipient Valid value entries for enable are yes no Valid value entries for recipient are Any valid company email account t Sends test email v Specifies verbose output XSCF setemailreport Enable Email Reporting no yes Email Recipient Address useradm company com Do you want to send a test mail now Yes No no XSCF setemailreport Enable Email Reporting yes RETURN Emai...

Page 183: ...he following exit values are returned SEE ALSO setsmtp 8 showemailreport 8 XSCF setemailreport t Sending test email to useradm company com Email contents shown below Host Name jupiter Send Timestamp 04 20 2006 16 31 45 PST Mail Server 10 4 1 1 0 Successful completion 0 An error occurred ...

Page 184: ...setemailreport 8 196 XSCF Reference Manual Last Revised January 2007 ...

Page 185: ...s delimited by a period If a domain name exceeding 254 characters is specified an error occurs A label element can contain alphanumeric characters and hyphens Each label element must always begin with an alphabetic character and end with an alphanumeric character h Displays usage statement When used with other options or operands an error occurs hostname Specifies a host name to be set for the XSC...

Page 186: ... name execute the applynetwork 8 command and reset the XSCF The currently set host name and DNS domain name of the XSCF unit can be checked by using the shownetwork 8 command EXAMPLES EXAMPLE 1 Sets the host name scf0 hostname for XSCF unit 0 EXAMPLE 2 Sets the DNS domain name example com for XSCF unit EXIT STATUS The following exit values are returned SEE ALSO applynetwork 8 rebootxscf 8 showhost...

Page 187: ...command starts or stops the HTTPS service which is used in the XSCF network Also this command performs authentication related settings for authentication used in the HTTPS service The following authentication related items can be set Configuring the self certification authority Creating a self signed web server certificate Creating the private key of the web server Creating a web server certificat...

Page 188: ...R c genserverkey Creates the private key of the web server c importca Imports a web server certificate signed by the certification authority to the XSCF c selfsign Configures the self certification authority Also this operand creates a self signing web server certificate h Displays usage statement When used with other options or operands an error occurs n Automatically answers n no to all prompts ...

Page 189: ...ing the c genserverkey option Confirm the validity of the web server certificate The information which has been set will be reflected by using the rebootxscf 8 command to reset XSCF The details of the current HTTPS service can be checked by using the showhttps 8 command EXAMPLES EXAMPLE 1 Starts the HTTPS service EXAMPLE 2 Stops the HTTPS service EXAMPLE 3 Creates a CSR with the following settings...

Page 190: ...ificate BEGIN CERTIFICATE MIIDdTCCAt6gAwIBAgIBATANBgkqhkiG9w0BAQQFADCBgTELMAkGA1UEBhMCamox DjAMBgNVBAgTBXN0YXRlMREwDwYDVQQHEwhsb2NhbGl0eTEVMBMGA1UEChMMb3Jn YW5pemF0aW9uMQ8wDQYDVQQLEwZvcmdhbmkxDzANBgNVBAMTBmNvbW1vbjEWMBQG CSqGSIb3DQEJARYHZWUubWFpbDAeFw0wNjA1MzAwNTI5MTVaFw0xNjA1MjcwNTI5 MTVaMG4xCzAJBgNVBAYTAmpqMQ4wDAYDVQQIEwVzdGF0ZTEVMBMGA1UEChMMb3Jn YW5pemF0aW9uMQ8wDQYDVQQLEwZvcmdhbmkxDzANBgNVBAMTB...

Page 191: ...sethttps 8 System Administration 205 EXIT STATUS The following exit values are returned SEE ALSO showhttps 8 0 Successful completion 0 An error occurred ...

Page 192: ...sethttps 8 206 XSCF Reference Manual Last Revised January 2007 ...

Page 193: ...stinguished name for the search base Maximum character length is 128 characters b bind Sets the identity to use when binding to the LDAP server Maximum character length is 128 characters c certchain Imports an LDAP server certificate chain from the remote file specified in certchain The certificate chain must be in PEM format Remote files are specified using the standard scp syntax that is user ho...

Page 194: ... to all configured LDAP servers Attempts to retrieve the password data for the specified user from each configured server and reports success or failure in each case T timeout Sets the maximum time allowed for an LDAP search before it returns search results XSCF setldap b user p Password Enter password XSCF showldap Bind Name user Base Distinguished Name Not set LDAP Search Timeout 0 Bind Password...

Page 195: ...se Distinguished Name ou people dc company dc com LDAP Search Timeout 60 Bind Password Set LDAP Servers ldap company com 389 ldaps company2 com 636 CERTS None XSCF setldap c user remote machine path to cacert pem XSCF showldap Bind Name user Base Distinguished Name ou people dc company dc com LDAP Search Timeout 60 Bind Password Set LDAP Servers ldap company com 389 ldaps company2 com 636 CERTS ca...

Page 196: ...setldap 8 210 XSCF Reference Manual Last Revised January 2007 ...

Page 197: ...ffective after the subsequent login The currently set locale can be checked by using the showlocale 8 command EXAMPLES EXAMPLE 1 Sets the XSCF default locale for English EXAMPLE 2 Sets the XSCF default locale for Japanese EXIT STATUS The following exit values are returned SEE ALSO showlocale 8 h Displays usage statement When used with other options or operands an error occurs s locale Specifies th...

Page 198: ...setlocale 8 212 XSCF Reference Manual Last Revised January 2007 ...

Page 199: ...NS The following option is supported OPERANDS The following operand is supported EXTENDED DESCRIPTION The showlocator 8 command can be used to check the CHECK LED state EXAMPLES EXAMPLE 1 Starts the CHECK LED blinking EXAMPLE 2 Stops the CHECK LED blinking Start blinking Makes the CHECK LED blink Stop blinking Stops the blinking of the CHECK LED h Displays usage statement When used with other opti...

Page 200: ...setlocator 8 214 XSCF Reference Manual Last Revised January 2007 EXIT STATUS The following exit values are returned SEE ALSO showlocator 8 0 Successful completion 0 An error occurred ...

Page 201: ...perands are supported EXAMPLES EXAMPLE 1 Enabling LDAP Lookup of Privilege Data EXIT STATUS The following exit values are returned SEE ALSO showlookup 8 a Sets the authentication lookup Used with one of the required operands ldap or local h Displays usage statement When used with other options or operands an error occurs p Sets privileges lookup Used with one of the required operands ldap or local...

Page 202: ...setlookup 8 218 XSCF Reference Manual Last Revised January 2007 ...

Page 203: ...t are currently registered This option is used with the c del c add Adds the host with the specified IP address as a DNS server This option is used together with address If the c option is omitted c add is assumed specified When a DNS server is registered the existing setting is deleted and overwriting is performed with the specified address c del Deletes the host with the specified IP address fro...

Page 204: ...n be checked by using the shownameserver 8 command EXAMPLES EXAMPLE 1 Adds the hosts with the IP addresses 192 168 1 2 10 18 108 10 and 10 24 1 2 as DNS server Names are solved in the order specified EXAMPLE 2 Deletes the host with the IP address 10 18 108 10 from the DNS server EXAMPLE 3 Deletes all the DNS servers EXIT STATUS The following exit values are returned SEE ALSO rebootxscf 8 shownames...

Page 205: ...s You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported c up down Specifies whether to enable the specified network interface One of the following values can be specified If none of them is specified an error occurs up Enables the network interface down Disables the network interface h Displays usage statement...

Page 206: ...setnetwork 8 224 XSCF Reference Manual Last Revised June 2007 OPERANDS The following operands are supported ...

Page 207: ...nge server For XSCF unit 0 xscf 0 lan 0 XSCF LAN 0 xscf 0 lan 1 XSCF LAN 1 xscf 0 if Interface between XSCF units Inter SCF Network ISN For abbreviation lan 0 an abbreviattion of XSCF LAN 0 lan 1 an abbreviattion of XSCF LAN 1 For high end server For XSCF unit 0 xscf 0 lan 0 XSCF LAN 0 xscf 0 lan 1 XSCF LAN 1 xscf 0 if Interface between XSCF units Inter SCF Network ISN For XSCF unit 1 when a dupli...

Page 208: ...fied a subnet which overlaps with DSCP When specified a subnet which overlaps between XSCF 0 if or xscf 1 if and the other interface When specified the c up down option and ISN together In case you specified the IP address and the netmask to the interfaces other than ISN and when the ISN is not configured the following default value will be set xscf 0 if IP address 192 168 1 1Å Netmask 255 255 255...

Page 209: ... 0 for XSCF LAN 0 on XSCF unit 1 EXAMPLE 6 Sets the IP address 192 168 1 10 and net mask 255 255 255 0 for the takeover IP address of XSCF LAN 0 EXIT STATUS The following exit values are returned SEE ALSO applynetwork 8 shownetwork 8 XSCF setnetwork xscf 0 if 192 168 10 128 XSCF setnetwork xscf 1 lan 0 m 255 255 255 0 192 168 11 10 XSCF setnetwork lan 0 m 255 255 255 0 192 168 1 10 0 Successful co...

Page 210: ...setnetwork 8 228 XSCF Reference Manual Last Revised June 2007 ...

Page 211: ...is regarded as the NTP server The stratum value which has been set to XSCF Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported a Deletes all the NTP servers that are currently registered This option is used with the c del c add Adds the host with the specified address or the host as an NTP server ...

Page 212: ...with the addresses 192 168 1 2 10 18 108 10 c stratum Sets the stratum value in case you regard XSCF as an NTP server h Displays usage statement When used with other options or operands an error occurs i stratum_no Specifies the stratum value This option is used together with the c stratum An integer from 1 to 14 can be specified If the stratum value not specified it is 5 address Specifies the IP ...

Page 213: ...re returned SEE ALSO rebootxscf 8 showntp 8 XSCF setntp 192 168 1 2 10 18 108 10 10 24 1 2 Please reset the XSCF by rebootxscf to apply the ntp settings XSCF setntp c del 10 18 108 10 Please reset the XSCF by rebootxscf to apply the ntp settings XSCF setntp ntp1 example com ntp2 example com Please reset the XSCF by rebootxscf to apply the ntp settings XSCF setntp c stratum i 7 Please reset the XSC...

Page 214: ...setntp 8 190 XSCF Reference Manual Last Revised November 2007 ...

Page 215: ...radm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported d dcredit Sets maximum number of digits in a password Each digit counts as one credit The minimum acceptable password length is decreased by one for each digit in the password up to dcredit digits Valid values are integers with value of zero or greater The initial setting i...

Page 216: ... when they are created The intial value is 999999 Valid values are integers with value of zero or greater m minlen Sets the minimum size for a new password Note minlen cannot be set less than 6 Valid values are integers with value of 6 or greater n mindays Sets the minimum number of days between password changes An initial value of zero for this field indicates that you can change the password at ...

Page 217: ... 8 u ucredit Sets the maximum credit for uppercase letters in a password The minimum acceptable password length is decreased by one for each digit in the password up to ucredit digits The initial setting is 1 w warn Sets the default number of days before password expiration at which to start warning the user This value is assigned to new user accounts when they are created The initial value is 7 V...

Page 218: ...setpasswordpolicy 8 236 XSCF Reference Manual Last Revised November 2007 ...

Page 219: ...ct at the next startup Privileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION The currently set warm up time and wait time before system startup can be checked by using the showpowerupdelay 8 command EXAMPLES EXAMPLE 1 Sets the warm up time to 10 minutes EXAMPLE 2 Set...

Page 220: ...setpowerupdelay 8 238 XSCF Reference Manual Last Revised January 2007 EXIT STATUS The following exit values are returned SEE ALSO showpowerupdelay 8 0 Successful completion 0 An error occurred ...

Page 221: ...nd domainadm must be assigned to a specific domain Other privileges do not have this ability Refer to the OPERANDS section and EXAMPLE 1 for details If no privileges are specified setprivileges deletes any local privilege data for the specified user Subsequently the user s privilege data is looked up in Lightweight Directory Access Protocol LDAP if LDAP privilege lookup is enabled If the none priv...

Page 222: ...view all states of all hardware assigned to the domains on which this privilege is held Can view all states of domains on which this privilege is held domainop Can view all states of all the hardware assigned to the domains on which this privilege is held Can view all states of all domains on which this privilege is held domains Specifies a domain or domains using the appropriate value for domainp...

Page 223: ...llows the administrator to restrict access to such operations on the Service Processor and domains platadm Can perform all Service Processor configuration other than the useradm and auditadm tasks Can assign and unassign hardware from domains perform domain and XSCF power operations and all operations on domain hardware assign unassign power and so on Can perform Service Processor failover operati...

Page 224: ...setprivileges 8 244 XSCF Reference Manual Last Revised January 2007 ...

Page 225: ...ilege to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported c add del Specifies a function for routing information One of the following values can be specified If none of them is specified an error occurs add Adds routing information del Deletes routing information g address Specifies a gateway address used for routing The specified value of ...

Page 226: ...sk value is set according to the class of the network address class Mask value A 255 0 0 0 B 255 255 0 0 C 255 255 255 0 If the m option is omitted and the host address specified by the n option net mask is not set If 0 0 0 0 specified by the n option net mask is invalid If specified with the c del option this option can t be omitted n address Specifies an IP address to which routing information i...

Page 227: ...SCF unit 0 EXAMPLE 2 Adds the routing of destination 192 168 1 0 and gateway 192 168 1 1 for XSCF LAN 1 on XSCF unit 0 EXAMPLE 3 Adds the routing of destination 192 168 1 0 and default net mask 255 255 255 0 for XSCF LAN 1 on XSCF unit 0 interface Specifies the network interface to be set with routing information One of the following values can be specified For midrange server For XSCF unit 0 xscf...

Page 228: ...tion 192 168 1 4 from XSCF LAN 1 on XSCF unit 0 EXAMPLE 7 Adds routing information for the default gateway 192 168 10 1 for XSCF LAN 1 on XSCF unit 0 EXIT STATUS The following exit values are returned SEE ALSO applynetwork 8 rebootxscf 8 showroute 8 XSCF setroute c del n 192 168 1 0 m 255 255 255 0 xscf 0 lan 1 XSCF setroute c add n 192 168 1 4 xscf 0 lan 1 XSCF setroute c del n 192 168 1 4 xscf 0...

Page 229: ...the wait time currently set is displayed Privileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION The currently set wait time can be displayed by using the showshutdowndelay 8 command EXAMPLES EXAMPLE 1 Sets 600 seconds as the wait time before the start of shutdown EXIT...

Page 230: ...setshutdowndelay 8 252 XSCF Reference Manual Last Revised January 2007 ...

Page 231: ...ll also be prompted for the port and the Reply To address to be used on outgoing email Make sure that a valid email address is specified here You can set up SMTP settings noninteractively using the s option After you have set up the email server and port have been set up using setsmtp 8 you can use setemailreport 8 to set up email report configuration data and send a test email message Privileges ...

Page 232: ...h other options or operands an error occurs s variable value Sets SMTP Valid entries for variable are mailserver port auth user password replyaddress Where auth is the authentication mechanism user password are the smtp mail server authentication Valid auth entries are none pop smtp auth v Specifies verbose output XSCF setsmtp s mailserver 10 4 1 1 s auth none XSCF setsmtp s auth pop s user jsmith...

Page 233: ...e following exit values are returned SEE ALSO setemailreport 8 showsmtp 8 XSCF setsmtp Mail Server 10 4 1 1 Port 25 Authentication Mechanism none Invalid value Valid authentication mechanism are none pop smtp auth Authentication Mechanism none Reply Address useradm company com 0 Successful completion 0 An error occurred ...

Page 234: ...setsmtp 8 256 XSCF Reference Manual Last Revised January 2007 ...

Page 235: ...bles or disables the SNMP Agent as well as configures the SNMP agent settings Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported c system contact Specifies the system contact information for the agent d system description Specifies the system description for the agent h Displays usage statement W...

Page 236: ...s the following options and operand p trap port ID of the trap port Default value is 162 s community string Acts like a password to control access to the SNMP v1 and v2 agents It is a clear text string which can be intercepted For password encryption and no visibility use addv3traphost instead t type Type of trap Valid trap types are v1 The agent will send SNMPv1 traps v2 The agent will send SNMPv...

Page 237: ...ost takes the following options a authentication password Sets the authentication password Must be equal to or greater than 8 characters e encryption password Sets the encryption password i Asks for an acknowledgment from the receiving host n engine_id Sets identifier of the local agent sending the trap It can be the engine ID of the local SNMP agent or not but it must match the engine ID expected...

Page 238: ...the SNMP agent from communicating using SNMPv1 v2c These versions provide insecure SNMP communication enable When used alone activates the SNMP agent with support for all MIB modules When used with the value ALL for the optional mib_name activates the SNMP agent with support for all MIB modules When used with a value other than ALL for the optional mib_name adds support for the targeted MIB module...

Page 239: ...rap types are v1 The agent will send SNMPv1 traps v2 The agent will send SNMPv2 traps inform The agent will send inform notifications traphost Host name of the trap host remv3traphost Disables the SNMP agent from sending SNMPv3 traps to the desired host traphost Host name of the trap host u username Specifies a valid user name XSCF setsnmp l sandiego c username company com d ff1 XSCF setsnmp addv3...

Page 240: ...setsnmp 8 262 XSCF Reference Manual Last Revised January 2007 SEE ALSO showsnmp 8 ...

Page 241: ...pusm delete user setsnmpusm clone u clone_user user setsnmpusm passwd c auth encrypt o old_password n new_password user setsnmpusm h DESCRIPTION setsnmpusm 8 modifies the SNMP Agent s USM configuration Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported h Displays usage statement When used with ot...

Page 242: ...ds are supported clone Makes the supplied user known to the agent for subsequent SNMP communication with the identical settings as the specified clone_user u clone_user Specifies a valid user name of the user settings to be cloned user Specifies a different user name for the clone of clone_user ...

Page 243: ...ntication_password Specifes the authentication password Must be equal to or greater than 8 characters delete Removes the supplied user making the user unknown to the agent for subsequent SNMP communication user Specifies a valid user name passwd Changes the appropriate password for the specified user The changed password is either the authentication password or the encrypted password or both if c ...

Page 244: ...oning a User EXAMPLE 4 Deleting a User EXIT STATUS The following exit values are returned SEE ALSO showsnmpusm 8 XSCF setsnmpusm create a SHA p xxxxxxxx e yyyyyyyy jsmith XSCF setsnmpusm create a SHA bob Authetication Password Encryption Password XSCF setsnmpusm clone u sue joe Authentication Password Encryption Password XSCF setsnmpusm delete joe 0 Successful completion 0 An error occurred ...

Page 245: ...vacm deleteview s OID_subtree viewname setsnmpvacm createaccess r read_viewname groupname setsnmpvacm deleteaccess groupname setsnmpvacm h DESCRIPTION setsnmpvacm 8 modifies the SNMP Agent s VACM configuration Using this command requires a basic knowledge of SNMP Privileges You must have platadm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following opti...

Page 246: ...identified through a MIB OID subtree and can be limited to specific portions of that subtree using the OID Mask e Specifies an excluded view The default is an included view m OID_Mask Specifies a valid OID subtree mask By default the mask is ff entire subtree s OID_subtree Specifies a MIB OID subtree Values start at 1 for the entire MIB tree viewname Specifies a valid view name deleteaccess Remove...

Page 247: ...e the Subtree Is Excluded EXAMPLE 4 Create Access EXIT STATUS The following exit values are returned SEE ALSO showsnmpvacm 8 XSCF setsnmpvacm createview s 1 all_view XSCF setsnmpvacm createview e s 1 3 6 1 2 1 1 m fe excl_view XSCF setsnmpvacm createaccess r all admin 0 Successful completion 0 An error occurred ...

Page 248: ...setsnmpvacm 8 274 XSCF Reference Manual Last Revised January 2007 ...

Page 249: ...key is displayed The user public key can be registered on each user account Per user account multiple user public keys can be registered Per user account the user public keys can be registered up to 1 023 characters including the linefeed Only SSH2 is supported for XSCF Privileges You must have one of the following privileges to run this command To start or stop the SSH service and to generate the...

Page 250: ... to reset XSCF The current SSH service settings can be checked by using the showssh 8 command c enable disable Specifies whether to enable the SSH service One of the following values can be specified enable Starts the SSH2 service disable Stops the SSH2 service c genhostkey Generates a host public key for SSH2 h Displays usage statement When used with other options or operands an error occurs n Au...

Page 251: ...pressing Ctrl D XSCF setssh c enable Continue y n y Please reset the XSCF by rebootxscf to apply the ssh settings XSCF setssh y c enable Continue y n y Please reset the XSCF by rebootxscf to apply the ssh settings XSCF setssh q y c enable XSCF setssh c disable XSCF setssh c genhostkey Host key create Continue y n y Please reset the XSCF by rebootxscf to apply the ssh settings XSCF setssh c genhost...

Page 252: ... c addpubkey u efgh Please input a public key ssh rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzFh95SohrDgpnN7zFCJCVNy jaZPTjNDxcid QGbihYDCBttI4151Y0Sv85FJwDpSNHNKoVLMYLjtBmUMPbGgGVB61qskSv FeV44hefNCZMiXGItIIpK P0nBK4XJpCFoFbPXNUHDw1rTD9icD5U wRFGSRRxFI Ub5oLRxN8 A8 abcd example com Enter Ctrl D XSCF setssh c delpubkey s 1 1 ssh rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzFh95SohrDgpnN7zFCJCVNy jaZPTjNDxcid QGbihYDCBtt...

Page 253: ...l be reflected to the active XSCF only In case you stop the Telnet service it will be reflected by using the rebootxscf 8 command to reset XSCF The current Telnet service state can be checked by using the showtelnet 8 command EXAMPLES EXAMPLE 1 Starts the Telnet service EXAMPLE 2 Stops the Telnet service EXIT STATUS The following exit values are returned c enable disable Specify whether to start t...

Page 254: ...settelnet 8 282 XSCF Reference Manual Last Revised June 2007 SEE ALSO rebootxscf 8 showtelnet 8 ...

Page 255: ...wing options are supported a Lists the time zones that can be set c settz Sets the time zone which complies with POSIX standards c adddst Manually sets the time zone and Daylight Saving Time c deldst Deletes the time zone and Daylight Saving Time b std Specifies the abbreviations of time zone For std specify an abbreviation of 3 letters or more You can specify it in the format which complies with ...

Page 256: ... to 6 0 for Sunday and 6 for Saturday Jn Jn Specifies the sequential day in the year to start Daylight Saving Time You can specify the integer from 1 to 365 1 for January 1st It doesn t count the leap year day n n Specifies the sequential day in the year to start Daylight Saving Time You can specify the integer from 1 to 365 1 for January 1st It counts the leap year day In time you specify the tim...

Page 257: ...unday and 6 for Saturday Jn Jn Specifies the sequential day in the year to start Daylight Saving Time You can specify the integer from 1 to 365 1 for January 1st It doesn t count the leap year day n n Specifies the sequential day in the year to start Daylight Saving Time You can specify the integer from 1 to 365 1 for January 1st It counts the leap year day In time you specify the time You can spe...

Page 258: ...m ss GMT Greenwich mean time Specifies to set the standard time to the time which is ahead of GMT To adjust to the local time east to Greenwich the offset is a negative value Specifies to set the standard time to the time which is behind the GMT To adjust to the local tome west to Greenwich the offset is a positive value hh mm ss Specifies the offset time hh is 00 23 mm is 00 59 ss is 00 59 ...

Page 259: ...es to set the standard time to the time which is ahead of GMT To adjust to the local time east to Greenwich the offset is a negative value Specifies to set the standard time to the time which is behind the GMT To adjust to the local tome west to Greenwich the offset is a positive value hh mm ss Specifies the offset time hh is 00 23 mm is 00 59 ss is 00 59 s timezone Specifies the time zone One of ...

Page 260: ...m w d Mm Specifies the month to terminate Daylight Saving Time For m you can specify any integer from 1 to 12 w Specifies the week to terminate Daylight Saving Time You can specify the integer from 1 to 5 1 for the first week and 5 for the last week in the month d Specifies the day of the week to terminate Daylight Saving Time You can specify the integer from 0 to 6 0 for Sunday and 6 for Saturday...

Page 261: ...et of Daylight Saving Time from GMT is 10 and the time period is from the first Sunday of April 0 00 to the first Sunday of Septem ber 0 00 EXAMPLE 5 Deletes the Daylight Saving Time information of current settings EXIT STATUS The following exit values are returned SEE ALSO setdate 8 showdate 8 showtimezone 8 XSCF settimezone c settz a Africa Abidjan Africa Accra Africa Addis_Ababa Africa Algiers ...

Page 262: ...settimezone 8 292 XSCF Reference Manual Last Revised January 2007 ...

Page 263: ...e Quad XSB is configured with one of divided PSB into four parts Specify either the Uni XSB configuration or Quad XSB configuration for the PSB Memory mirror mode In mirror mode data is mirrored by dividing the memory mounted on a PSB into two parts Since the memory is divided into two parts the memory capacity is halved but data reliability increases Specify whether to operate the memory in mirro...

Page 264: ...mory board and one I O unit in combination In a midrange server the PSB consists of one CPU module and one memory module logically divided into two on the motherboard and one I O module The current PSB settings can be checked by using the showfru 8 command EXAMPLES EXAMPLE 1 Configures PSB 00 as a Quad XSB with memory in non mirror mode be cause the memory mirror mode setting is omitted EXIT STATU...

Page 265: ...nterfaces on the SPARC Enterprise M4000 M5000 servers are xscf 0 lan 0 xscf 0 lan 1 lan 0 lan 1 The available interfaces on the SPARC Enterprise M8000 M9000 servers are the same but they also include the xscf 0 if xscf 1 lan 0 xscf 1 lan 1 and xscf 1 if In user setup a new local user account can be created with a user supplied password In network setup the following items can be optionally configu...

Page 266: ...assword not echoed XSCF setupplatform Do you want to set up an account y n n Do you want to set up the XSCF network interfaces y n y Do you want to configure xscf 0 lan 0 y n y xscf 0 lan 0 ip address 192 168 1 4 xscf 0 lan 0 netmask 255 255 255 0 255 255 254 0 xscf 0 lan 0 default gateway 192 168 1 1 xscf 0 lan 0 ip address 192 168 1 4 xscf 0 lan 0 netmask 255 255 254 0 xscf 0 lan 0 default gatew...

Page 267: ...latform p timezone Do you want to set up the XSCF time zone y n y Chassis time zone is already configured XSCF time zone US Pacific Continue setting up the XSCF time zone y n y 0 Africa Abidjan 1 Africa Accra 2 Africa Addis_Ababa 3 Africa Algiers 4 Africa Asmera 5 Africa Bamako 6 Africa Bangui 7 Africa Banjul 8 Africa Bissau 9 Africa Blantyre 10 Africa Brazzaville 11 Africa Bujumbura 12 Africa Cai...

Page 268: ...following exit values are returned SEE ALSO adduser 8 applynetwork 8 password 8 setaltitude 8 setdscp 8 setemailreport 8 sethostname 8 sethttps 8 setnameserver 8 setnetwork 8 setntp 8 setprivileges 8 setsmtp 8 setssh 8 setroute 8 settimezone 8 0 Successful completion 0 An error occurred ...

Page 269: ...ple of 100 meters Privileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXTENDED DESCRIPTION The setaltitude 8 command sets the altitude of the server EXAMPLES EXAMPLE 1 Displays the altitude of the system EXIT STATUS The following exit values are returned SEE ALSO setaltitude 8 h Displays...

Page 270: ...showaltitude 8 304 XSCF Reference Manual Last Revised January 2007 ...

Page 271: ...g options are supported EXTENDED DESCRIPTION If the e option is not specified showarchiving displays the following information 1 A list of archiving configuration data e Displays information about the last ten archiving errors h Displays usage statement When used with other options or operands an error occurs v Specifies verbose output Archiving state Log archiving is enabled or disabled Archive h...

Page 272: ... the identity of the archive host This field is not displayed unless the v option is specified Archive host fingerprint The md5 fingerprint of the public key which the Service Processor uses to verify the identity of the archive host Latest communication The completion time of the latest attempt to communicate with the archive host Connection status The outcome of the latest attempt to connect to ...

Page 273: ... Archive host Not configured Archive directory Not configured User name for ssh login Not configured Archive host fingerprint Server authentication disabled Connection to Archive Host Latest communication None Connection status None AUDIT LOGS OTHER LOGS Archive space limit Unlimited 2000 MB Archive space used Not monitored Not monitored Total archiving failures 0 0 Unresolved failures 0 0 XSCF sh...

Page 274: ...showarchiving 8 308 XSCF Reference Manual Last Revised January 2007 ...

Page 275: ...ers c classes e events g m p s t showaudit h DESCRIPTION showaudit 8 displays the current state of system auditing When invoked without options showaudit displays whether the writing of audit records is enabled or disabled Privileges You must have auditadm or auditop privileges to run this command Refer to setprivileges 8 for more information ...

Page 276: ...AD 4 Commands that read a current state ACS_LOGIN 8 Login related events ACS_AUDIT 16 Audit related events ACS_DOMAIN 32 Domain management related events ACS_USER 64 User management related events ACS_PLATFORM 128 Platform management related events ACS_MODES 256 Mode related events e events Displays the audit record generation policy for the specified audit events events is a comma separated list ...

Page 277: ...plays the thresholds at which to issue warning s about local storage usage all Displays the following information Whether the writing of audit trails is set to enable or disable This is the same display that is shown for showaudit when invoked without any options All the information that would be displayed by invoking showaudit with the options a c all e all g m p s XSCF showaudit Auditing enabled...

Page 278: ...S The following exit values are returned SEE ALSO setaudit 8 viewaudit 8 AEV_LOGIN_SSH enabled AEV_LOGIN_TELNET enabled AEV_LOGOUT enabled AEV_AUTHENTICATE enabled AEV_addboard enabled AEV_addcodlicense enabled AEV_addfru enabled 0 Successful completion 0 An error occurred ...

Page 279: ...is set by default Privileges You must have one of the following privileges to run this command useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displays the session timeout time of the XSCF shell EXAMPLE 2 Displays the session timeout time of the XSCF shell the ti...

Page 280: ...showautologout 8 316 XSCF Reference Manual Last Revised January 2007 ...

Page 281: ... ID One of the following is displayed 00 23 Domain ID to which the XSB is assigned SP This is displayed if the XSB does not belong to any domain but is located in the system board pool Other This is displayed if the XSB belongs to a domain to which no user privilege has been granted LSB Logical system board LSB number defined for the domain The displayed number is an integer ranging from 0 to 15 A...

Page 282: ...f an initial diagnosis on an XSB Unmount The XSB cannot be recognized because it is not mounted or because it has an error Unknown Not performed Testing The initial diagnosis is in progress Passed The initial diagnosis ended normally Failed Error test fail detected by an initial diagnosis The XSB cannot be used or is in a degraded state Fault XSB degradation status Normal Normal Degraded Component...

Page 283: ...ard pool System boards in the system board pool do not belong to any domain d domain_id Specifies the ID of the domain whose status of XSB is displayed Only information that is defined with the DCL of the specified domain is displayed An integer ranging from 0 to 23 can be specified for domain_id depending on the system configuration h Displays usage statement When used with other options or opera...

Page 284: ...ru 8 XSCF showboards v a XSB R DID LSB Assignment Pwr Conn Conf Test Fault COD 00 0 00 00 Assigned y y y Passed Normal n 00 1 00 01 Assigned y y y Passed Normal n 00 2 SP Available y n n Passed Normal n 00 3 02 00 Unavailable y n n Unknown Normal n XSCF showboards 00 0 XSB DID LSB Assignment Pwr Conn Conf Test Fault 00 0 15 00 Assigned y y y Passed Normal XSCF showboards v 00 0 XSB R DID LSB Assig...

Page 285: ... Privileges You must have platadm platop domainadm domainop or domainmgr privileges for the specified domain Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Displaying COD Information for All Domains on an OPL System The output shown is what you would see if you had domainadm domainop or domainmgr privileges for Domain 1 d domain_id Doma...

Page 286: ... PROC RTUs reserved for domain 1 0 PROC RTUs reserved for domain 2 0 PROC RTUs reserved for domain 3 0 PROC RTUs reserved for domain 4 0 PROC RTUs reserved for domain 5 0 PROC RTUs reserved for domain 6 0 PROC RTUs reserved for domain 7 0 PROC RTUs reserved for domain 8 0 PROC RTUs reserved for domain 9 0 PROC RTUs reserved for domain 10 0 PROC RTUs reserved for domain 11 0 PROC RTUs reserved for ...

Page 287: ... the COD license information EXAMPLE 1 Displaying Formatted License Data h Displays usage statement When used with other options or operands an error occurs r Displays the license information in the raw license signature format as stored in the COD license database v Specifies verbose output Displays both the formatted license information and raw license signature data Description Type of resource...

Page 288: ...7 EXAMPLE 2 Displaying Raw License Data EXIT STATUS The following exit values are returned SEE ALSO addcodlicense 8 deletecodlicense 8 showcodusage 8 XSCF showcodlicense r 01 84000000 104 0301010100 3 00000000 xxxxxxxxxxxxxxx 0 Successful completion 0 An error occurred ...

Page 289: ...mainadm domainmgr domainop Can run this command for available resources only for those domains that you can access Refer to setprivileges 8 for more information OPTIONS The following options are supported h Displays usage statement When used with other options or operands an error occurs M Displays text by page This option provides a function that is the same as that of the more command p domain D...

Page 290: ...es OK Indicates that there are sufficient licenses for the COD CPUs in use Also displays the number of remaining COD resources available and the number of any instant access CPUs headroom available HEADROOM The number of instant access COD CPUs in use Violation Indicates a COD RTU license violation exists Displays the number of COD CPUs in use that exceeds the number of COD RTU licenses available ...

Page 291: ...resources installed in the domain Reserved Specifies the number of COD RTU licenses allocated to the domain Status Contains one of the following when the v option is specified Licensed The domain COD CPU has a COD RTU license and is in use Unlicensed A COD RTU license for the domain COD CPU could not be obtained and it is not in use Unused The COD CPU is not in use XSCF showcodusage p resource Res...

Page 292: ...2 PROC 0 1 CMU00 CPU2 Unused 00 3 PROC 0 1 CMU00 CPU3 Unused 02 0 PROC 0 4 CMU02 CPU0 Unused CMU02 CPU1 Unused CMU02 CPU2 Unused CMU02 CPU3 Unused 1 PROC 0 0 0 2 PROC 0 0 0 3 PROC 0 0 0 4 PROC 0 0 0 5 PROC 0 0 0 6 PROC 0 0 0 7 PROC 0 0 0 8 PROC 0 0 0 9 PROC 0 0 0 10 PROC 0 0 0 11 PROC 0 0 0 12 PROC 0 0 0 13 PROC 0 0 0 14 PROC 0 0 0 15 PROC 0 0 0 Unused PROC 0 0 2 XSCF showcodusage v Resource In Us...

Page 293: ...showcodusage 8 System Administration 335 EXIT STATUS The following exit values are returned SEE ALSO addcodlicense 8 deletecodlicense 8 showcodlicense 8 0 Successful completion 0 An error occurred ...

Page 294: ...showcodusage 8 336 XSCF Reference Manual Last Revised June 2007 ...

Page 295: ...ollowing options are supported User User account of the XSCF connected to the domain console DID Domain ID ro rw Domain console type ro Read only console rw Writable console escape Escape mark specified for the console Date Date connected to the domain console useradm platadm platop Can run this command for all domains domainadm domainmgr domainop Can run this command only for your accessible doma...

Page 296: ...isplays console information on all domains that can be accessed EXIT STATUS The following exit values are returned SEE ALSO console 8 sendbreak 8 XSCF showconsolepath a User DID ro rw escape Date nakagawa 00 rw Fri Jul 29 21 23 34 hana 00 ro Fri Jul 29 09 49 12 k okano 00 ro Fri Jul 29 18 21 50 yuuki 01 rw Fri Jul 29 10 19 18 uchida 01 ro Fri Jul 29 13 30 41 0 Successful completion 0 An error occu...

Page 297: ...of the following operations is performed Rebooting the domain The NTP time synchronization processing after the change of date and time of XSCF with the date 8 command Privileges You must have one of the following privileges to run this command useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options a...

Page 298: ...sed January 2007 EXAMPLE 2 Displays the current time in UTC EXIT STATUS The following exit values are returned SEE ALSO setdate 8 settimezone 8 showtimezone 8 XSCF showdate u Mon Jan 23 05 56 15 UTC 2006 0 Successful completion 0 An error occurred ...

Page 299: ... system boards LSBs that are components of a domain An LSB is a board unit recognized by an operating system in a domain Up to 16 LSBs can be registered for each domain and they are represented by integer numbers ranging from 0 to 15 An XSB is a board unit that can be used in the system and is one division of a divided physical system board PSB An XSB is represented by x y a combination of a PSB n...

Page 300: ...s One of the following status is displayed Additional information may be displayed Powered Off Power is off Panic State A panic occurred and the domain is in the reset state Shutdown Started The power off process is starting Initialization Phase OpenBoot PROM initialization is in progress OpenBoot Executing Completed The system is in the OpenBoot PROM ok prompt state Booting OpenBoot PROM prompt T...

Page 301: ...is displayed True Omits the use of memory on a domain False Does not omits the use of memory on a domain default No IO Whether to omit the use of I O devices on a domain Either of the following is displayed True Omits the use of I O devices on a domain False Does not omit the use of I O devices on a domain default Float Whether to set a priority for the specified LSB as a floating board relative t...

Page 302: ...lays information that is set for all domains d domain_id Specifies the ID of the domain for which information is to be displayed The domain_id can be 0 23 depending on the system configuration h Displays usage statement When used with other options or operands an error occurs l lsb Specifies the LSB number whose information is to be displayed Specify an lsb value by using an integer ranging from 0...

Page 303: ...he domain component list that is set for domain ID 0 XSCF showdcl v d 0 DID LSB XSB Status No Mem No IO Float Cfg policy 00 Running FRU 00 00 0 False False False 01 02 03 04 01 0 False True False 05 06 07 08 02 0 True True True 09 10 11 12 03 0 True True False 13 14 15 ...

Page 304: ...showboards 8 showdevices 8 showfru 8 XSCF showdcl v a DID LSB XSB Status No Mem No IO Float Cfg policy 00 Running FRU 00 00 0 False False False 01 02 03 04 01 0 False True False 05 06 07 08 02 0 True True True 09 10 11 12 03 0 True True False 13 14 15 01 Running Waiting for OS Shutdown FRU 00 01 2 True True False 01 04 0 False False False 02 03 04 05 06 07 05 0 True False False 08 09 10 11 12 13 1...

Page 305: ...es can be obtained for the devices managed by the operating system The command can also display in advance whether the XSB can be disconnected from the domain using the dynamic reconfiguration DR function The following types of information are displayed Common CPU MEMORY DID Domain ID XSB XSB number id processor ID state status of processor speed CPU frequency MHz ecache CPU external cache size MB...

Page 306: ...ge Description of the instance using resources query Results of an off line inquiry about resources platadm platop fieldeng Can run this command for all domains domainadm domainmgr domainop Can run this command only for your accessible domains d domain_id Specifies the ID of the domain for which information is to be displayed domain_id can be 0 23 depending on the system configuration h Displays u...

Page 307: ...g system when a system board is disconnected by deleteboard command If the p option is omitted p bydevice is used v Displays information on all I O devices including those that are not management targets As information on the I O devices that are not management targets however only physical configurations are displayed and resources and use states are not displayed xsb Specifies the XSB number for...

Page 308: ...ng DID XSB mem MB mem MB address mem MB XSB mem MB mem MB 00 00 0 2048 1290 0x000003c000000000 2048 03 0 250 1500 00 00 1 2048 0 0x0000038000000000 2048 0 0 00 00 2 2048 0 0x0000034000000000 2048 0 0 00 00 3 2048 0 0x0000030000000000 2048 0 0 00 01 0 2048 0 0x000002c000000000 2048 1024 0 00 02 0 2048 0 0x0000028000000000 2048 0 0 IO Devices DID XSB device resource usage 00 00 0 sd3 dev dsk c0t3d0s...

Page 309: ... 2048 4 00 01 0 51 on line 2048 4 00 01 0 52 on line 2048 4 00 01 0 53 on line 2048 4 Memory board perm base domain target deleted remaining DID XSB mem MB mem MB address mem MB XSB mem MB mem MB 00 00 0 2048 1290 0x000003c000000000 4096 00 1 250 1500 00 01 0 2048 0 0x000002c000000000 4096 IO Devices DID XSB device resource usage 00 00 0 sd0 00 00 0 sd1 00 00 0 sd2 00 00 0 sd3 dev dsk c0t3d0s0 mou...

Page 310: ...showdevices 8 358 XSCF Reference Manual Last Revised January 2007 ...

Page 311: ...vel One of the following is displayed none None min Standard max Maximum Secure Mode Displays the states of the host watchdog function and function that suppresses break signal reception Break signal One of the following is displayed on Enabled off Disabled Autoboot Displays the state of the auto boot function used at domain startup One of the following is displayed on Enabled off Disabled platadm...

Page 312: ...ode 8 command display Secure Mode off Autoboot off When the OpenBoot PROM environmental variable auto boot has been set to false the auto boot function is disabled The setdomainmode 8 command sets a domain mode EXAMPLES EXAMPLE 1 Displays the current state of the operation mode for domain ID 0 EXIT STATUS The following exit values are returned SEE ALSO setdomainmode 8 XSCF showdomainmode d 0 Host ...

Page 313: ...following privileges to run this command Powered Off Power is off Panic State A panic occurred and the domain is in the reset state Shutdown Started The power off process is starting Initialization Phase OpenBoot PROM initialization is in progress OpenBoot Execution Completed The system is in the OpenBoot PROM ok prompt state Booting OpenBoot PROM prompt The operating system is booting Or due to t...

Page 314: ... run this command only for your accessible domains a Displays status information on all domains that can be accessed d domain_id Specifies only one ID of the domain to be displayed domain_id can be 0 23 depending on the system configuration h Displays usage statement When used with other options or operands an error occurs XSCF showdomainstatus a DID Domain Status 00 Running 01 Running Waiting for...

Page 315: ...ar domain or just the Service Processor then the output is not a table but simply the IP address of the specified domain or Service Processor The p option can be used to generate parsable output that would then be suitable for use in a script Parsable displays of individual IP addresses exclude any additional labels and only an IPv4 address in dotted decimal form is output The parsable version of ...

Page 316: ...valid IP addresses for your network Using invalid network IP addresses could under certain circumstances make your system unbootable d domain_id Displays an individual domain s IP address h Displays usage statement When used with other options or operands an error occurs p Generates parsable output s Displays the Service Processor s IP address v Specifies verbose output Prints additional informati...

Page 317: ... Domain 01 10 1 1 3 Domain 02 10 1 1 4 Domain 03 10 1 1 5 Domain 04 10 1 1 6 Domain 05 10 1 1 7 Domain 06 10 1 1 8 Domain 07 10 1 1 9 Domain 08 10 1 1 10 Domain 09 10 1 1 11 Domain 10 10 1 1 12 Domain 11 10 1 1 13 Domain 12 10 1 1 14 Domain 13 10 1 1 15 Domain 14 10 1 1 16 Domain 15 10 1 1 17 Domain 16 10 1 1 18 Domain 17 10 1 1 19 Domain 18 10 1 1 20 Domain 19 10 1 1 21 Domain 20 10 1 1 22 Domain...

Page 318: ... following exit values are returned SEE ALSO setdscp 8 XSCF showdscp p Network 10 1 1 0 Netmask 255 255 255 0 XSCF 10 1 1 1 Domain 0 10 1 1 2 Domain 1 10 1 1 3 Domain 2 10 1 1 4 Domain 3 10 1 1 5 Domain 4 10 1 1 6 Domain 5 10 1 1 7 Domain 6 10 1 1 8 Domain 7 10 1 1 9 Domain 8 10 1 1 10 Domain 9 10 1 1 11 0 Successful completion 0 An error occurred ...

Page 319: ...hanged settings are displayed Privileges You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Displays the current setting of dual power feed mode in the system EXAMPLE 2 Changes the dual power feed mode with the setdualpowerfeed 8 com mand and then displays the current state EX...

Page 320: ...showdualpowerfeed 8 374 XSCF Reference Manual Last Revised January 2007 ...

Page 321: ...privileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION Emailreport information includes whether Emailreporting is enabled If enabled it also includes the list of addresses EXAMPLES EXAMPLE 1 Displaying Emailreport configuration EXIT STATUS The following exit values are returned SEE ALSO setemailreport 8 h Displays usage statement When used with other opt...

Page 322: ...showemailreport 8 376 XSCF Reference Manual Last Revised June 2007 ...

Page 323: ...ported Environment information Intake temperature and humidity of the system humidity only for high end server Temperature information Intake temperature of the system and exhaust temperature of each component Voltage information Voltage sensor value Fan rotation information Fan rotational state and revolutions per unit of time h Displays usage statement When used with other options or operands an...

Page 324: ...mperature information about the system and each component XSCF showenvironment Temperature 30 71C Humidity 90 05 XSCF showenvironment temp Temperature 30 71C CMU 0 30 71C CPUM 0 CHIP 0 30 71C CPUM 1 CHIP 0 30 71C CPUM 2 CHIP 0 30 71C CPUM 3 CHIP 0 30 71C CMU 1 30 71C CPUM 0 CHIP 0 30 71C CPUM 1 CHIP 0 30 71C CPUM 2 CHIP 0 30 71C CPUM 3 CHIP 0 30 71C CMU 2 30 71C CPUM 0 CHIP 0 30 71C CPUM 1 CHIP 0 ...

Page 325: ...2 5V Power Supply Group 2 500V MEMB 2 1 2V Power Supply Group 1 200V 1 8V Power Supply Group 1 700V 2 5V Power Supply Group 2 500V MEMB 3 1 2V Power Supply Group 1 200V 1 8V Power Supply Group 1 700V 2 5V Power Supply Group 2 500V IOU 0 1 0V Power Supply Group 1 020V 1 2V Power Supply Group 1 180V 1 5V Power Supply Group 1 500V 1 8V Power Supply Group 1 850V 2 5V Power Supply Group 2 510V 3 3V Pow...

Page 326: ...nt Fan FAN_A 0 Low speed FAN_A 0 4101rpm FAN_A 1 Low speed FAN_A 1 4101rpm FAN_A 2 Low speed FAN_A 2 4177rpm FAN_A 3 Low speed FAN_A 3 4101rpm PSU 0 PSU 0 Low speed PSU 0 3879rpm PSU 0 3835rpm PSU 1 PSU 1 Low speed PSU 1 3924rpm PSU 1 3970rpm PSU 2 PSU 2 Low speed PSU 2 4218rpm PSU 2 4066rpm PSU 3 PSU 3 Low speed PSU 3 3835rpm PSU 3 3970rpm 0 Successful completion 0 An error occurred ...

Page 327: ...t have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported Device Specified device name Only sb is displayed Location Device location If the device is sb the indicated location is an integer ranging from 00 to 15 XSB Mode XSB mode set for the PSB One of the following values is displayed Uni Uni XSB Quad Quad X...

Page 328: ...EE ALSO addboard 8 deleteboard 8 moveboard 8 setdcl 8 setupfru 8 showboards 8 showdcl 8 showdevices 8 device Specifies the device to display Currently only the following device can be specified sb Physical system board PSB location Specifies the location of device If the device is sb an integer ranging from 00 to 15 can be specified XSCF showfru a sb Device Location XSB Mode Memory Mirror Mode sb ...

Page 329: ... to setprivileges 8 for more information OPTIONS The following options are supported useradm platadm platop fieldeng Can run this command for all domains domainadm domainmgr domainop Can run this command only for your accessible domains h Displays usage statement When used with other options or operands an error occurs M Displays text by page This option provides a function that is the same as tha...

Page 330: ...mally XSCF showhardconf SPARC Enterprise M5000 Serial BE80601021 Operator_Panel_Switch Service Power_Supply_System Single SCF ID XSCF 0 System_Power On System_Phase Cabinet Power On Domain 0 Domain_Status Powered Off MBU_B Status Normal Ver 0101h Serial 7867000297 FRU Part Number CA20393 B50X A2 Memory_Size 64 GB CPUM 0 CHIP 0 Status Normal Ver 0201h Serial PP0629L068 FRU Part Number CA06761 D104 ...

Page 331: ...s Normal Code c1000000000000005372T128000HR3 7A 356d 0d016a13 Type 1B Size 1 GB MEM 2B Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d016417 Type 1B Size 1 GB MEM 3A Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d017617 Type 1B Size 1 GB MEM 3B Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d016b12 Type 1B Size 1 GB DDC_A 0 Status Normal DDC_A 1 Status Normal ...

Page 332: ...B MEM 2A Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d016a13 Type 1B Size 1 GB MEM 2B Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d016417 Type 1B Size 1 GB MEM 3A Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d017617 Type 1B Size 1 GB MEM 3B Status Normal Code c1000000000000005372T128000HR3 7A 356d 0d016b12 Type 1B Size 1 GB DDC_A 0 Status Normal DDC_A 1 ...

Page 333: ...atus Normal XSCFU Status Normal Active Ver 0101h Serial 7867000262 FRU Part Number CA20393 B56X A0 OPNL Status Normal Ver 0101h Serial 7867000087 FRU Part Number CA00629 D061 A0 PSU 0 Status Normal Serial 0000000 ASTECB10 FRU Part Number CF00300 1898 0002 300 1898 00 02 Power_Status Off AC 200 V PSU 1 Status Normal Serial 0000000 ASTECB18 FRU Part Number CF00300 1898 0002 300 1898 00 02 Power_Stat...

Page 334: ...rdconf 8 304 XSCF Reference Manual Last Revised November 2007 EXIT STATUS The following exit values are returned PSU 30 FANBP_A 2 FANBP_B 2 FAN_A 32 SWBP 2 MEDBP 2 0 Successful completion 0 An error occurred ...

Page 335: ...ed EXTENDED DESCRIPTION In case the XSCF unit is duplicated configuration a defect occurred on standby XSCF unit shows a message The sethostname 8 command sets a host name for an XSCF unit EXAMPLES EXAMPLE 1 Displays the current host names for all XSCF units a Displays the current host names for all XSCF units If an XSCF unit name is specified with the a option the XSCF unit name is ignored h Disp...

Page 336: ... Revised January 2007 EXAMPLE 2 Displays the host name for XSCF unit 0 EXIT STATUS The following exit values are returned SEE ALSO sethostname 8 XSCF showhostname xscf 0 xscf 0 scf0 hostname example com 0 Successful completion 0 An error occurred ...

Page 337: ...You must have one of the following privileges to run this command useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following option is supported EXTENDED DESCRIPTION The sethttps 8 command make settings for the HTTPS service in the XSCF network HTTPS Status Indicates whether the HTTPS service is operating Server...

Page 338: ...AYDVQQIEwVzdGF0ZTERMA8G A1UEBxMIbG9jYWxpdHkxFTATBgNVBAoTDG9yZ2FuaXphdGlvbjEPMA0GA1UECxMG b3JnYW5pMQ8wDQYDVQQDEwZjb21tb24xFjAUBgkqhkiG9w0BCQEWB2VlLm1haWww gZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJAoGBAJ5D57X k42LcipTWBWzv2GrxaVM 5GEyx3bdBW8 7WZhnd3uiZ9 ANlvRAuw YYy7I pAD NQJesBcBjuyj9x IiJl9F MrI5fR8pOIywVOdbMPCar09rrU45bVeZhTyi uQOdWLoX Dhq0fm2BpYuh9WukT5 pTEg 2dABg8UdHmNAgMBAAGgADANBgkqhkiG9w0BAQQFAAOBgQA...

Page 339: ...un this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Displaying All LDAP Configuration Data EXAMPLE 2 Displaying All LDAP Configuration Data EXIT STATUS The following exit values are returned SEE ALSO setldap 8 c Displays the LDAP server certification chain h Displays usage statement When used with other options or operands an...

Page 340: ...showldap 8 402 XSCF Reference Manual Last Revised June 2007 ...

Page 341: ... domainadm domainmgr domainop Refer to setprivileges 8 for more information OPTIONS The following option is supported EXTENDED DESCRIPTION The setlocale 8 command sets a locale for the XSCF EXAMPLES EXAMPLE 1 Displays the current setting for the XSCF locale when English is set EXAMPLE 2 Displays the current setting for the XSCF locale when Japanese is set EXIT STATUS The following exit values are ...

Page 342: ...showlocale 8 404 XSCF Reference Manual Last Revised January 2007 ...

Page 343: ...8 for more information OPTIONS The following option is supported EXTENDED DESCRIPTION The setlocator 8 command can be used to specify the blink state of the CHECK LED EXAMPLES EXAMPLE 1 Displays the CHECK LED state EXIT STATUS The following exit values are returned SEE ALSO setlocator 8 Off Indicates normal operation which means either the circuit breaker is off or power is not being supplied Blin...

Page 344: ...showlocator 8 406 XSCF Reference Manual Last Revised January 2007 ...

Page 345: ...target for the log collection the following logs can be specified Privileges You must have one of the following privileges to run this command Error log Event log Temperature and humidity record and Monitor message log platadm platop fieldeng Power log platadm platop domainadm domainmgr fieldeng Scan log fieldeng Console message log Panic message log and IPL message log platadm platop domainadm do...

Page 346: ...is option can be specified for an error log or event log timestamp is specified in one of the following formats yyyy mm dd hh mm ss The timestamp is specified in the year month day hour minute second format mm dd yy hh mm ss The timestamp is specified in the month day year hour minute second format Monddhh mm ssyyyy The timestamp is specified in the month name day hour minute second year format r ...

Page 347: ... year hour minute format Monddhh mmyyyy The timestamp is specified in the month name day hour minute year format yyyy mm dd hh mm ss The timestamp is specified in the year month day hour minute second format mm dd yy hh mm ss The timestamp is specified in the month day year hour minute second format Monddhh mm ssyyyy The timestamp is specified in the month name day hour minute second year format E...

Page 348: ...d in the month name day hour minute second year format Even if the r option is specified together with this option the specified t and T options are not reversed The T option cannot be used for the monitoring message log v Displays a log in detail Details of Diagnostic Codes UUID and MSG ID which are used by the fmadm 8 and fmdump 8 commands are also displayed in addition to the items normally dis...

Page 349: ...lays the console message log panic Displays the panic message log ipl Displays the IPL message log Date Mar 30 17 45 31 JST 2005 Code xxxxxxxx xxxxxxxx xxxxxxxxxxxxxxxx Status Alarm Occurred Mar 30 17 45 31 000 JST 2005 FRU PSU 1 PSU 2 Msg ACFAIL occurred ACS 3 FEP type A1 Date Mar 30 17 45 31 JST 2005 Code xxxxxxxx xxxxxxxx xxxxxxxxxxxxxxxx Status Alarm Occurred Mar 30 17 45 31 000 JST 2005 FRU P...

Page 350: ...1 JST 2005 Code xxxxxxxx xxxxxxxx xxxxxxxxxxxxxxxx Status Alarm Occurred Mar 30 17 45 31 000 JST 2005 FRU PSU 1 PSU 2 Msg ACFAIL occurred ACS 3 FEP type A1 Diagnostic Code xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx UUID bf36f0ea 9e47 42b5 fc6f c0d979c4c8f4 MSG ID FMD 8000 11 Detail log SCAN MINOR RC 2K 0000 xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx...

Page 351: ...cted faulty units are detected Msg Error description Diagnostic Code Detailed error code The displayed code is a hexadecimal number UUID Abbreviation for Universal Unique Identifier This is a globally unique ID that is a 32 digit hexadecimal number MSG ID Unique message ID Diagnostic Messages Detailed message If the log has a detailed message it is displayed Detail log Scan log code This code is d...

Page 352: ...set XSCF is in the reset state Domain Reset XSCF is in the reset state XIR XSCF is in the reset state Cause Factor that caused this Status One of the following factors is displayed Self Reset Power On System Reset Panel Scheduled RCI AC Restored Operator Poweron Restart Power Failure SW Request Alarm Fatal Panic DID Domain ID domain_id can be 0 23 depending on the system configuration Switch Statu...

Page 353: ... displayed time is the local time Message Event message Switch Status of the mode switch of the operator panel One of the following states are displayed Locked Normal operation mode Service Service mode RCIaddr Remote Cabinet Interface RCI address If RCI is supported the RCI address is displayed as an eight digit hexadecimal number Code Detailed event information The displayed information is in he...

Page 354: ...ar The displayed time is the local time Temperature Intake air temperature Decimal numbers are displayed to two decimal places The unit is degree Celsius C Humidity Humidity The displayed numbers are percentages However nothing is displayed for the midrange server Power Power state of the main unit Either of the following states is displayed System Power ON The main unit power is on System Power O...

Page 355: ...y has a date and time paired with an IPL message panic Date Mar 30 18 45 31 JST 2005 DomainID 00 Mar 30 17 45 31 JST 2005 panic message Mar 30 17 55 31 JST 2005 panic message Date Panic occurrence date and time month day hour minute second time zone year The displayed time is the local time DomainID Domain ID domain_id can be 0 23 depending on the system configuration ipl Date Mar 30 18 45 31 JST ...

Page 356: ...s Alarm Occurred Mar 30 17 45 31 000 JST 2005 FRU PSU 1 PSU 2 Msg ACFAIL occurred ACS 3 FEP type A1 XSCF showlogs error p Mar3012 45 312005 v Date Mar 30 12 45 31 JST 2005 Code 00112233 44556677 8899aabbcceeff0 Status Alarm Component IOU 0 PCI 3 Msg offline vendor FUJITSU product MAJ3182MC Diagnostic Code 00112233 44556677 8899aabb 00112233 44556677 8899aabb ccddeeff 00112233 44556677 8899aabb ccd...

Page 357: ...Operator 00 Service Mar 30 17 45 31 JST 2005 Domain Power Off Operator 00 Locked Mar 30 17 35 31 JST 2005 System Power On AC Restored Locked Mar 30 17 25 31 JST 2005 System Power Off Power Failure Service XSCF showlogs power t Mar3017 302005 T Mar3017 492005 Date Event Cause DID Switch Mar 30 17 35 31 JST 2005 System Power On AC Restored Locked Mar 30 17 45 31 JST 2005 Domain Power Off Operator 00...

Page 358: ...CF Reference Manual Last Revised January 2007 Note The codes or messages shown here may differ from those actually displayed EXIT STATUS The following exit values are returned 0 Successful completion 0 An error occurred ...

Page 359: ...ges You must have useradm or fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displaying Settings for Authentication and Privileges EXIT STATUS The following exit values are returned SEE ALSO setlookup 8 h Displays usage statement XSCF showlookup Privileges lookup Local only Authentication lookup Loca...

Page 360: ...showlookup 8 424 XSCF Reference Manual Last Revised January 2007 ...

Page 361: ...tered the contents of the message are displayed To stop the real time display press the Ctrl C key combination Privileges You must have one of the following privileges to run this command platadm platop fieldeng Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displays the contents of a monitoring message in real time EXIT STATUS The follow...

Page 362: ...showmonitorlog 8 426 XSCF Reference Manual Last Revised January 2007 ...

Page 363: ...nformation OPTIONS The following option is supported EXTENDED DESCRIPTION The setnameserver 8 command sets the DNS servers used in the XSCF network EXAMPLES EXAMPLE 1 Displays the DNS servers currently set for the XSCF network The follow ing example shows that three DNS servers have been set EXAMPLE 2 Displays the DNS servers currently set for the XSCF network The follow ing example shows that no ...

Page 364: ...shownameserver 8 428 XSCF Reference Manual Last Revised January 2007 ...

Page 365: ...ollowing privileges to run this command useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options are supported xscf x y XSCF network interface name HWaddr MAC address hexadecimal notation inet addr IP address Bcast Broadcast Mask Net mask UP DOWN Whether the network interface is enabled a Displays info...

Page 366: ...it 0 xscf 0 lan 0 XSCF LAN 0 xscf 0 lan 1 XSCF LAN 1 xscf 0 if Interface between XSCF units Inter SCF Network ISN For abbreviation lan 0 an abbreviattion of XSCF LAN 0 lan 1 an abbreviattion of XSCF LAN 1 For high end server For XSCF unit 0 xscf 0 lan 0 XSCF LAN 0 xscf 0 lan 1 XSCF LAN 1 xscf 0 if Interface between XSCF units Inter SCF Network ISN For XSCF unit 1 when a duplicated configuration is...

Page 367: ...rmation for ISN on the XSCF unit 0 XSCF shownetwork xscf 0 lan 1 xscf 0 lan 1 Link encap Ethernet HWaddr 00 00 00 12 34 56 inet addr 192 168 10 11 Bcast 192 168 10 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 54424 errors 0 dropped 0 overruns 0 frame 0 TX packets 14369 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 20241827 19 3 ...

Page 368: ...2 168 11 255 Mask 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 54424 errors 0 dropped 0 overruns 0 frame 0 TX packets 14369 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 14541827 13 8 MiB TX bytes 1459769 1 3 MiB Base address 0x1000 XSCF shownetwork lan 0 lan 0 Link encap Ethernet HWaddr 00 00 00 12 34 56 inet addr 192 168 1 10 Bcast 192...

Page 369: ...55 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 54424 errors 0 dropped 0 overruns 0 frame 0 TX packets 14369 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 20241827 19 3 MiB TX bytes 2089769 1 9 MiB Base address 0x1000 xscf 0 if Link encap Ethernet HWaddr 00 00 00 00 00 00 inet addr 192 168 10 128 Bcast 192 168 10 255 Mask 255 255 255 0 UP BR...

Page 370: ...shownetwork 8 434 XSCF Reference Manual Last Revised June 2007 ...

Page 371: ...o setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Display Only Copyright Information EXAMPLE 2 Display Copyright and License Information c copyright license Specifies for display by page either the copyright file or the license file for the XCP copyright Specifies for display only the copyright file license Specifies for display only the license ...

Page 372: ...shownotice 8 436 XSCF Reference Manual Last Revised January 2007 ...

Page 373: ...leges 8 for more information OPTIONS The following options are supported OPERANDS The following operand is supported EXTENDED DESCRIPTION The setntp 8 command sets the NTP servers used in the XSCF network a Displays all the NTP servers currently set for the XSCF network h Displays usage statement When used with other options or operands an error occurs l Displays whether synchronization with an NT...

Page 374: ...TATUS The following exit values are returned SEE ALSO setntp 8 XSCF showntp a server ntp1 example com prefer 1 ntp server name server ntp2 example com 2 ntp server name XSCF showntp l remote refid st t when poll reach delay offset jitter 192 168 0 27 192 168 1 56 2 u 27 64 377 12 929 2 756 1 993 192 168 0 57 192 168 1 86 2 u 32 64 377 13 030 2 184 94 421 127 127 1 0 LOCAL 0 5 l 44 64 377 0 000 0 0...

Page 375: ...to keep in password history for each user Privileges You must have useradm privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displaying Password Policy Settings EXIT STATUS The following exit values are returned SEE ALSO setpasswordpolicy 8 h Displays usage statement XSCF showpasswordpolicy Mindays 0 Maxdays 99...

Page 376: ...showpasswordpolicy 8 442 XSCF Reference Manual Last Revised January 2007 ...

Page 377: ...his command platadm platop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION The setpowerupdelay 8 command sets the warm up time of the system and a wait time before system startup EXAMPLES EXAMPLE 1 Displays the warm up time of the system and wait time before system star tup EXIT STATUS The followin...

Page 378: ...showpowerupdelay 8 444 XSCF Reference Manual Last Revised January 2007 ...

Page 379: ... remote control program to confirm whether the most recently executed command is successfully completed Privileges No privileges are required to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 display the exit status of setupfru 8 EXIT STATUS The following exit values are returned h Displays usage statement XSCF setupfru...

Page 380: ...showresult 8 446 XSCF Reference Manual Last Revised January 2007 ...

Page 381: ...ivileges You must have one of the following privileges to run this command useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options are supported Destination Destination IP address Gateway Gateway address Netmask Netmask address Flags Flag which indicates the status of specified routing U route is up H...

Page 382: ... the more command n Displays IP address without the name resolution of host name interface Specifies the network interface whose information is to be displayed One of the following values can be specified depending on the system configuration If this operand is specified with the a option the operand is ignored For XSCF unit 0 xscf 0 lan 0 XSCF LAN 0 xscf 0 lan 1 XSCF LAN 1 For XSCF unit 1 when a ...

Page 383: ...eturned SEE ALSO setroute 8 XSCF showroute n xscf 0 lan 0 Destination Gateway Netmask Flags Interface 192 168 10 0 255 255 255 0 U xscf 0 lan 0 default 192 168 10 1 0 0 0 0 UG xscf 0 lan 0 XSCF showroute a Kernel IP routing table Destination Gateway Netmask Flags Interface 192 168 10 0 255 255 255 0 U xscf 0 lan 0 default 192 168 10 1 0 0 0 0 UG xscf 0 lan 0 Destination Gateway Netmask Interface d...

Page 384: ...showroute 8 450 XSCF Reference Manual Last Revised June 2007 ...

Page 385: ...me set by the setshutdowndelay 8 command is displayed The default time set is 10 seconds Privileges You must have one of the following privileges to run this command platadm platop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Displays the wait time before the start of shutdown EXIT STATUS The foll...

Page 386: ...showshutdowndelay 8 452 XSCF Reference Manual Last Revised January 2007 ...

Page 387: ...8 for more information OPTIONS The following options are supported EXTENDED DESCRIPTION SMTP information includes the Mail Server and Reply addresses EXAMPLES EXAMPLE 1 Displaying SMTP configuration EXIT STATUS The following exit values are returned SEE ALSO setsmtp 8 h Displays usage statement When used with other options or operands an error occurs v Specifies verbose output XSCF showsmtp Mail S...

Page 388: ...showsmtp 8 454 XSCF Reference Manual Last Revised January 2007 ...

Page 389: ...on OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displaying SNMP Information for a System That Has Not Been Set Up EXAMPLE 2 Displaying SNMP Information for a Disabled System Set Up With SNMPv3 Trap Host h Displays usage statement XSCF showsnmp Agent Status Disabled Agent Port 161 System Location Unknown System Contact Unknown System Description Unknown Trap Hosts None SNMP V1 V2c N...

Page 390: ...mp 8 XSCF showsnmp Agent Status Enabled Agent Port 161 System Location SanDiego System Contact jsmith jupiter west System Description FF1 Trap Hosts Hostname Port Type Community String Username Auth Protocol host1 162 v1 public jsmith SHA host2 162 v2c public n a n a host3 162 v3 n a bob SHA SNMP V1 V2c Status Enabled Community String public Enabled MIB Modules SP_MIB FM_MIB 0 Successful completio...

Page 391: ... the SNMP agent Privileges You must have platadm or platop privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displaying SNMP Information for a System EXIT STATUS The following exit values are returned SEE ALSO setsnmpusm 8 h Displays usage statement XSCF showsnmpusm Username Auth Protocol jsmith SHA sue MD5 0 S...

Page 392: ...showsnmpusm 8 460 XSCF Reference Manual Last Revised January 2007 ...

Page 393: ...have platadm or platop privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displaying SNMP Information for a System EXIT STATUS The following exit values are returned SEE ALSO setsnmpvacm 8 h Displays usage statement XSCF showsnmpvacm Groups Groupname Username admin jsmith bob Views View Subtree Mask Type all_vie...

Page 394: ...showsnmpvacm 8 462 XSCF Reference Manual Last Revised January 2007 ...

Page 395: ...ic key are displayed Only SSH2 is supported for XSCF Privileges You must have one of the following privileges to run this command To display the user public key of other user account useradm To display the information other than above useradm platadm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following options are support...

Page 396: ...B3NzaC1yc2EAAAABIwAAAIEAt0IG3wfpQnGr51znS9XtzwHcBBb UU0LN08SilUXE6j avlxdY7AFqBf1wGxLF Tx5pTa6HuZ8o8yUBbDZVJAAAAFQCfKPxarV 5qzK4A43Qaigkqu 6QAAAIBM LQl22G8pwibESrh5JmOhSxpLzl3P26ksI8qPr 7BxmjLR0k Fingerprint 1024 e4 35 6a 45 b4 f7 e8 ce b0 b9 82 80 2e 73 33 c4 etc ssh ssh_host_rsa_key pub DSA key ssh dss AAAAB3NzaC1kc3MAAACBAJSy4GxD7Tk4fxFvyW1D0NUDqZQPY3PuY2IG7QC4BQ1kewDnblB8 JEqI 8pnfbWzmOWU37KHL...

Page 397: ...ohrDgpnN7zFCJCVNy jaZPTjNDxcid QGbihYDCBttI4151Y0Sv85FJwDpSNHNKoVLMYLjtBmUMPbGgGVB61qskSv FeV44hefNCZMiXGItIIpK P0nBK4XJpCFoFbPXNUHDw1rTD9icD5U wRFGSRRxFI Ub5oLRxN8 A8 abcd example com 2 ssh rsa CSqGSIb3DQEJARYHZWUubWFpbDCBnzANBgkqhkiG9w0BAQEFAAOBjQAwgYkCgYEA nkPntf TjYtyKlNYFbO YavFpUzkYTLHdt0Fbz tZmGd3e6Jn34A2W9EC7D9hjLsj kAP41Al6wFwGO7 KP3H4iImX0Uysjl9Hyk4jLBU51sw8JqvT2utTjltV5mFPKL6bDcAgY9 efg...

Page 398: ...showssh 8 466 XSCF Reference Manual Last Revised January 2007 ...

Page 399: ...EXAMPLES EXAMPLE 1 Displays the degraded units In this example a CPU module and memory module in a CPU memory unit are degraded because of an error h Displays usage statement When used with other options or operands an error occurs M Displays text by page This option provides a function that is the same as that of the more command Status Description Faulted The component is faulty and is not opera...

Page 400: ...rd unit are degraded because of an error EXAMPLE 4 Displays the degraded units In this example a CPU memory unit is de graded because a crossbar unit is degraded EXIT STATUS The following exit values are returned XSCF showstatus MBU_B MEMB 0 MEM 0A Status Faulted XSCF showstatus MBU_B Status Normal MEMB 1 Status Deconfigured MEM 3B Status Deconfigured XSCF showstatus MBU_B Status Normal CPUM 1 CHI...

Page 401: ...dm platop auditadm auditop domainadm domainmgr domainop fieldeng Refer to setprivileges 8 for more information OPTIONS The following option is supported EXTENDED DESCRIPTION The settelnet 8 command makes settings for the Telnet service in the XSCF network EXAMPLES EXAMPLE 1 Displays the status of the Telnet service for the XSCF network EXIT STATUS The following exit values are returned SEE ALSO se...

Page 402: ...showtelnet 8 472 XSCF Reference Manual Last Revised January 2007 ...

Page 403: ...e showtimezone 8 command displays the XSCF time zone and Daylight Saving Time information of current settings It is displayed in the following format std offset dst offset2 from date time to date time std Abbreviations of time zone offset Offset time of time zone and Greenwich mean time GMT Displayed in minus in case the offset is plus and displayed in plus in case the offset is minus dst Name of ...

Page 404: ...light Saving Time starts Any numeric from 1 to 5 comes in 1 for the first week and 5 for the last week in the month d Shows the day of the week when Daylight Saving Time starts Any numeric from 0 to 6 comes in 0 for Sunday and 6 for Saturday Jn Jn The date when Daylight Saving Time starts Any numeric from 1 to 365 comes in 1 for January 1st The leap year day is not counted n n The date when Daylig...

Page 405: ...Time starts Any numeric from 1 to 5 comes in 1 for the first week and 5 for the last week in the month d Shows the day of the week when Daylight Saving Time starts Any numeric from 0 to 6 comes in 0 for Sunday and 6 for Saturday Jn Jn The date when Daylight Saving Time starts Any numeric from 1 to 365 comes in 1 for January 1st The leap year day is not counted n n The date when Daylight Saving Tim...

Page 406: ...mes in 1 for the first week and 5 for the last week in the month d Shows the day of the week when start Daylight Saving Time terminates Any numeric from 0 to 6 comes in 0 for Sunday and 6 for Saturday Jn Jn The date when Daylight Saving Time terminates Any numeric from 1 to 365 comes in 1 for January 1st The leap year day is not counted n n The date when Daylight Saving Time terminates Any numeric...

Page 407: ...EXAMPLE 3 Displays the Daylight Saving Time information as follows the abbrevia tion of time zone is JST the offset from GMT is 9 the name of Daylight Saving Time is JDT Daylight Saving Time is 1 hour ahead and the time pe riod is from the first Sunday of April 0 00 to the first Sunday of September 0 00 EXAMPLE 4 When no Daylight Saving Time is set EXIT STATUS The following exit values are returne...

Page 408: ...showtimezone 8 478 XSCF Reference Manual Last Revised January 2007 ...

Page 409: ...ion Privileges No privileges are needed for you to view your own account You must have useradm privileges to run this command for any other user Refer to setprivileges 8 for more information OPTIONS The following options are supported OPERANDS The following operands are supported a Displays password validity and account state information This is only valid for XSCF user accounts h Displays usage s...

Page 410: ...values are returned SEE ALSO adduser 8 deleteuser 8 disableuser 8 enableuser 8 password 8 setprivileges 8 XSCF showuser a User Name jsmith Status Enabled Minimum 0 Maximum 99999 Warning 7 Inactive 1 Last Change Aug 22 2005 Password Expires Never Password Inactive Never Account Expires Never XSCF showuser p User Name jsmith Privileges domainadm 1 3 6 8 9 platadm 0 Successful completion 0 An error o...

Page 411: ...tes it in the format of a zip archive snapshot stores the collected data on a remote network host or on an external media device based upon the use of the t T or d option To store the collected data on a remote network host using the t option you must specify a host name or IP address a target directory on the remote network host and the user name of a user on the remote host If you have already s...

Page 412: ...tprivileges 8 for more information OPTIONS The following options are supported D directory Used with the T option specifies a value for directory instead of the value set using setarchiving 8 The directory field must not begin with a hyphen or a tilde Refer to the description of the T option for more detailed information d device Specifies the external media device to use The following option is a...

Page 413: ...If you reject the key snapshot exits without doing anything This is the default behavior in SSH Target Mode if k is not specified public The specified public key is used for server authentication The host key argument should be the complete public key of the network host beginning with key type the complete contents of etc ssh ssh_host_rsa_key pub on the network host Note The public key should be ...

Page 414: ...thentication If you reject the key snapshot exits without doing anything This is the default behavior in SSH Target Mode if k is not specified public The specified public key is used for server authentication The host key argument should be the complete public key of the network host beginning with key type the complete contents of etc ssh ssh_host_rsa_key pub on the network host Note The public k...

Page 415: ...ive value for directory Note The user must create the target directory on the remote host snapshot does not create the target directory t user host directory Sets the network host and remote directory for data destination The host field specifies the host name or IP address of the network host The user field specifies the user name for the ssh login to the archive host The directory field specifie...

Page 416: ...evice should be formatted using the FAT32 file system As in SSH Target mode you can use the e option to encrypt the zip file in this mode However no transmission encryption such as SSH occurs in this mode since the data stays local to the Service Processor EXAMPLES EXAMPLE 1 Downloading a Public Key Using SSH EXAMPLE 2 Downloading a Host Key XSCF snapshot t joe jupiter west home joe logs x k downl...

Page 417: ...ser bob on host mars east Log only mode No commands will be collected Setting up ssh connection to remote host Collecting data into joe jupiter west home joe logs x archive zip Data collection complete XSCF snapshot t bob mars east home bob logs x k none e P password Output data will be encrypted Enter ssh password for user bob on host mars east Setting up ssh connection to remote host Collecting ...

Page 418: ...ZQNxJaYA0W058Qgxbn Key fingerprint in md5 c9 e0 bc b2 1a 80 29 24 13 d9 f1 13 f5 5c 2c 0f Accept this public key yes no no Public Key declined Error opening SSH target Exiting with error 1 XSCF snapshot t fakeuser fakehost com fakedir p fake password Downloading Public Key from fakehost com Error downoading key for host fakehost com Error opening SSH target Exiting with error 1 XSCF snapshot d usb...

Page 419: ...and and XSCFs cannot be switched check whether the addfru 8 deletefru 8 replacefru 8 or flashupdate 8 maintenance command is being executed If the command is being executed wait until the command ends If XSCFs cannot be switched though none of those maintenance commands is being executed use the f option to switch them Privileges You must have platadm or fieldeng privileges to run this command Ref...

Page 420: ...of the XSCF unit that the user is currently logged in to to standby EXAMPLE 2 Switches the state of the XSCF unit that the user is currently logged in to to standby Automatically answers y to all prompts EXIT STATUS The following exit values are returned XSCF switchscf t Standby The XSCF unit switch between the Active and Standby states Continue y n y XSCF switchscf t Standby y The XSCF unit switc...

Page 421: ...b 8 command performs an initial diagnosis of the specified PSB The configuration of the PSB and operation of each device mounted on the PSB are checked After the diagnostics the result is displayed The PSB must not be configured in the domain or the domain in which the PSB configured must be powered off The result also can be seen in Test and Fault displayed by showboards 8 command Privileges You ...

Page 422: ...itions not satisfied it leads to an error The system has been powered off All of the target PSB are Uni XSB expansion Diagnoses all the PSB that are mounted on the expansion cabinet If the following conditions not satisfied it leads to an error All of the target PSB are not operating on the domain All of the target PSB are Uni XSB h Displays usage statement When used with other options or operands...

Page 423: ...d Enter y to execute the command or n to cancel the command The displayed diagnostic results of the testsb 8 command are as follows XSB XSB numbers belonging to the specified PSBs One XSB number is displayed for the Uni XSB type and four XSB numbers are displayed for the Quad XSB type Test Status of the initial diagnosis of XSBs One of the following status values is displayed Unmount No XSB could ...

Page 424: ...ec 0 30 60 90 120end Initial diagnosis has completed SB power off sequence started 1200sec 0 end SB powered off XSB Test Fault 00 0 Passed Normal 00 1 Passed Normal 00 2 Passed Normal 00 3 Passed Normal XSCF testsb v 1 Initial diagnosis is about to start Continue y n y SB 01 powered on sequence started Initial diagnosis has completed 0 ok SB power off sequence started 1200sec 0 end SB powered off ...

Page 425: ...is about to start Continue y n y Ignore warmup time and air conditioner wait time Continue y n y SB power on sequence started 0end Initial diagnosis started 1800sec 0 30 60 90 120end Initial diagnosis has completed SB power off sequence started 1200sec 0 end SB powered off XSB Test Fault 00 0 Passed Normal 01 0 Passed Normal 02 0 Passed Normal 03 0 Passed Normal 0 Successful completion 0 An error ...

Page 426: ...testsb 8 500 XSCF Reference Manual Last Revised January 2007 ...

Page 427: ...ibly release the locked status of XSCF Privileges You must have fieldeng privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported EXAMPLES EXAMPLE 1 Unlocks the maintenance lock status h Displays usage statement When used with other options or operands an error occurs n Automatically answers n no to all prompts q Suppresses all messag...

Page 428: ... unlocks the maintenance lock which prevents the multiple execution of maintenance commands Never use this command except when the lock state remains by some reason Careless execution of this command causes serious situation because it interrupts the running command and XSCF might not be able to recognize the parts Continue y n y XSCF unlockmaintenance q y XSCF XSCF unlockmaintenance n This comman...

Page 429: ...ackage XCP firmware currently applied to the system cmu The version of OpenBoot PROM firmware xscf The version of XSCF firmware c xcp Displays the XCP version c cmu Displays the version of OpenBoot PROM firmware c xscf Displays the version of XSCF firmware h Displays usage statement When used with other options or operands an error occurs t Displays information of the XCP version that is registere...

Page 430: ... Current 1020 OpenBoot PROM 01 01 0001 SCF 01 01 0001 XCP1 Reserve 1020 OpenBoot PROM 01 01 0001 OpenBoot PROM BACKUP 0 01 01 0001 1 01 02 0001 XSCF 1 Standby XCP0 Current 1020 OpenBoot PROM 01 01 0001 SCF 01 01 0001 XCP1 Reserve 1020 OpenBoot PROM 01 01 0001 SCF 01 01 0001 OpenBoot PROM BACKUP 0 01 01 0001 1 01 02 0001 XSCF version c xcp t XCP 1020 XSCF version c xcp v t XCP 1020 OpenBoot PROM 01...

Page 431: ...omainID 02 01 01 0001 DomainID 03 01 01 0001 DomainID 23 01 01 0001 XSB 00 0 01 01 0001 Current 01 01 0001 Reserve XSB 00 1 01 01 0001 Reserve 01 01 0001 Current XSB 00 2 01 01 0001 Current 01 01 0001 Reserve XSB 00 3 01 01 0001 Current 01 01 0001 Reserve XSB 15 3 01 01 0001 Current 01 01 0001 Reserve XSCF version c xscf XSCF 0 Active 01 01 0001 Current 01 01 0001 Reserve XSCF 1 Standby 01 01 0001...

Page 432: ...version 8 508 XSCF Reference Manual Last Revised January 2007 ...

Page 433: ...ed in text format one token per line with a comma as the field separator The output can be modified using the C E l m del n S or x option Privileges You must have auditadm or auditop privileges to run this command Refer to setprivileges 8 for more information OPTIONS The following options are supported A date time Selects records that occurred at or after date time The date time argument is in loc...

Page 434: ...ute or offset Absolute date time yyyymmdd hh mm ss where yyyy year 1970 is the earliest valid value mm month 01 12 dd day 01 31 hh hour 00 23 mm minutes 00 59 ss seconds 00 59 Offset date time n d h m s where n number of units d days h hours m minutes s seconds Offset is only available with the B option and must be used with A The default value is 00 for hh mm and ss C Appends the number of record...

Page 435: ...t Absolute date time yyyymmdd hh mm ss where yyyy year 1970 is the earliest valid value mm month 01 12 dd day 01 31 hh hour 00 23 mm minutes 00 59 ss seconds 00 59 Offset date time n d h m s where n number of units d days h hours m minutes s seconds Offset is only available with the B option and must be used with A The default value is 00 for hh mm and ss C Appends the number of records that match...

Page 436: ...vents ACS_AUDIT 16 Audit related events ACS_DOMAIN 32 Domain management related events ACS_USER 64 User management related events ACS_PLATFORM 128 Platform management related events ACS_MODES 256 Mode related events D date time Selects records that occurred on a specific day a 24 hour period beginning at 00 00 00 of the day specified and ending at 23 59 59 The day specified is in local time in the...

Page 437: ...owing the label subject in an audit file For example in the following listing the audit id is 1 shown in boldface for emphasis subject 1 bob normal telnet 45880 jupiter l Prints one line per record m del Uses del as the field delimiter instead of the default delimiter which is the comma If del has special meaning for the shell it must be quoted The maximum size of a delimiter is three characters T...

Page 438: ...piter header 37 1 login telnet jupiter 2006 01 11 11 31 09 659 05 00 subject 1 jsmith normal ssh 45880 jupiter command showuser platform access granted return 0 XSCF viewaudit p granted file 1 2006 01 11 10 52 30 391 05 00 20060111155230 0000000000 jupiter header 37 1 login telnet jupiter 2006 01 11 11 31 09 659 05 00 subject 1 jsmith normal ssh 45880 jupiter command showuser platform access grant...

Page 439: ...mars company com 2006 01 26 16 12 16 127 05 00 subject 0 opl normal ssh 40952 apps command viewaudit platform access denied XSCF viewaudit l A 20070515 B 20070516 C S 1 E 5 file 1 2007 05 07 10 47 56 753 07 00 20070507174756 0000000000 san ff2 36 0 header 37 1 login telnet san ff2 36 0 West Sun COM 2007 05 15 00 12 03 880 07 00 subject 1084 root escalation telnet 56444 recon West Sun COM header 37...

Page 440: ...viewaudit 8 516 XSCF Reference Manual Last Revised June 2007 ...

Page 441: ...l used Idle time Login time Remote host name Privileges No privileges are required to run this command Refer to setprivileges 8 for more information OPTIONS The following option is supported EXAMPLES EXAMPLE 1 Displays a list of the user accounts who are logged in to the XSCF EXIT STATUS The following exit values are returned h Displays usage statement XSCF who USER TTY IDLE FROM HOST scf pts 0 00...

Page 442: ...who 1 518 XSCF Reference Manual Last Revised January 2007 ...

Page 443: ......

Page 444: ......

Reviews: