Note on BIOS or iRMC S5 firmware restore feature
BIOS or iRMC S5 firmware restore feature is executed at the same time
as the power cord is connected after the system board replacement.
Depending on the configuration of your server the firmware restore
requires different time, see
"States of power-on indicator and time
duration during firmware restore" on page 552
9 - 23 minutes (systems without PFR feature),
18 - 38 minutes (systems with PFR feature).
Do not perform the following operations after connecting the power cord.
Please wait for the above time to elapse.
–
Remove and reinsert the power cord
–
Power button on/off
–
Connecting and disconnecting other cables, etc.
"Concluding steps" on page 529
Note on MicroSD card
The MicroSD card on the system board contains the BIOS/iRMC
firmware that is running.
After replacing the system board, the operating version number will be
restored based on this information. Do not replace the system board and
the MicroSD card at the same time.
Note on TPM
The system board can be equipped with an optional TPM. This module
enables third party programs to store key information (e. g. drive
encryption using Windows Bitlocker Drive Encryption).
If the customer is using TPM functionality, the TPM has to be removed
from the defective system board and connected to the new system
board. For more information, see
"Replacing the TPM" on page 488
The TPM has to be enabled in the system BIOS.
System board and components
RX2540 M6
Upgrade and Maintenance Manual
521
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...