After replacing a network controller or the system board, switch on and boot
the server, see
"Switching on the server" on page 69
The hardware configuration tool for Red Hat Linux, will launch at boot and
detect the new and/or changed hardware on your system.
▶
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
If the system board or network controller offers multiple LAN ports, it
is necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
▶
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.3.11 Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see
"Suspending BitLocker functionality" on page 87
to complete the service task.
▶
If applicable, ask the system administrator to enter the recovery key in order
to boot the OS.
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting
the server after the maintenance task. However, if BitLocker
functionality has not been suspended, Windows will enter recovery
mode and ask you to input recovery key for further booting.
▶
Ask the system administrator to enable the previously suspended BitLocker
protection on the system volume, using the
BitLocker Drive Encryption
control panel item:
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
Basic software procedures
RX2540 M6
Upgrade and Maintenance Manual
105
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...