Figure 15: Locking the cable clamp of a PSU
▶
Pull the cable clamp up (1).
▶
Thread the power cord through the cable clamp (2).
▶
Press the cable clamp down until it engages to secure the cable (3).
It will take about 60 seconds until the server can be powered on.
4.7.2
Connecting the power cord (DC PSU)
Example DC PSU -48 V
CAUTION
The DC PSU adjusts automatically to any mains voltage in the range
from -40.5 V - -57 V.
▶
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
Basic hardware procedures
66
Upgrade and Maintenance Manual
RX2540 M6