Select the
Configuration
menu.
▶
Select the
Security Configuration
submenu.
▶
Set the
TPM Support
setting to
Disabled
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Removing the TPM
▶
Remove the system board, see
"Removing the defective system board" on
.
▶
Lay the system board on a soft, antistatic surface with its component side
facing down.
Figure 342: Removing the TPM screw
System board and components
486
Upgrade and Maintenance Manual
RX2540 M6