For a system with liquid cooling, proceed as follows:
▶
Remove the LC kit, see
"Removing the LC kit" on page 370
.
▶
Remove all memory modules, see
.
Before removing the memory modules, take a note on the
installation slot number for each memory module. Ensure that you
reinstall the memory modules in the slot they were located before
the replacement.
CAUTION
In case of Optane PMem modules are not reinstalled in the right
slots, data can be lost!
▶
"Removing a riser module" on page 70
.
▶
"Removing the fan cage" on page 74
▶
"Removing the cross bar" on page 80
▶
If applicable, remove all expansion cards, see
▶
Remove the iRMC microSD card, see
"Removing the iRMC microSD card"
.
▶
If applicable, remove all M.2 SSDs, see
.
▶
If applicable, remove the Dual microSD 64GB Enterprise, see
the Dual microSD 64GB Enterprise" on page 510
.
Removing the defective system board
▶
Disconnect all cables from the system board.
System board and components
524
Upgrade and Maintenance Manual
RX2540 M6
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...