"Removing the fan cage" on page 74
▶
Release all HDD modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD module" on page 149
CAUTION
The HDD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page 146
.
Removing the defective 10x 3.5-inch HDD backplane
▶
If applicable, remove the internal RAID riser module, see
internal RAID riser module" on page 273
.
▶
Disconnect all cables from the HDD backplane.
Figure 63: Removing the 10x 3.5-inch HDD backplane
▶
Release the eight screws (see circles).
▶
Take out the HDD backplane at a slight angle.
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M6
Upgrade and Maintenance Manual
153
Summary of Contents for PRIMERGY RX2540 M6
Page 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Page 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Page 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Page 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Page 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Page 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Page 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Page 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Page 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Page 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...