7.5.16
Replacing the 4x 2.5-inch PCIe SSD backplane
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 43
▶
"Suspending BitLocker functionality" on page 65
.
▶
"Shutting down the server" on page 45
.
▶
"Disconnecting the power cord" on page 46
.
▶
Remove all PCIe SSD modules from the server, see
CAUTION
▶
Ensure that all PCIe SSD modules are uniquely identified so that
you can reinsert them into their original bays after replacing the
PCIe SSD backplane.
▶
"Getting access to the component" on page 47
▶
"Removing the air duct" on page 58
.
▶
"Removing the fan holder" on page 60
Removing the defective 4x 2.5-inch PCIe SSD backplane
▶
Remove the PCIe SSD backplane, see
"Removing the 4x 2.5-inch PCIe
Installing the new 4x 2.5-inch PCIe SSD backplane
▶
Install the PCIe SSD backplane, see
"Installing the 4x 2.5-inch PCIe SSD
.
Hard disk drive (HDD) / solid state disk (SSD)
RX2520 M5
Upgrade and Maintenance Manual
207
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...