Press the cable clamp down until it disengages (1).
▶
Open the cable clamp (2).
▶
Disconnect the power cord from the PSU and remove it from the cable
clamp.
4.4
Getting access to the component
4.4.1
Safety notes
CAUTION
▶
Only for non-hot plug components:
●
Before removing or attaching covers, turn off the server, all
peripheral devices, and any other connected devices.
●
Because there is a risk of electric shock or damage, please
disconnect all power cords from the outlet.
▶
The top cover must be replaced as soon as possible for purposes
of cooling, to comply with EMC regulations (regulations regarding
electromagnetic compatibility) and to prevent fires.
▶
"Important information" on page 29
.
4.4.2
Extending the server out of the rack
CAUTION
▶
Use the anti-tilt plate to prevent the rack from tipping when
installing the rack. Pulling the server out of the rack without having
installed the anti-tilt plate may cause the rack to tip over.
▶
Be careful not to pinch fingers or clothes when sliding out the
server or pushing it back. Failure to do so may cause injury.
▶
"Important information" on page 29
.
Basic hardware procedures
RX2520 M5
Upgrade and Maintenance Manual
47
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...