# of
Beep
Description
Action
1
Invalid password
▶
Check for the correct password and try
again. Make sure that the caps lock key
is deactivated.
5
No Console Input
devices
1
or Output
devices
2
are found
Booting will continue.
1
Serial console redirection is considered
a console output device if enabled.
2
Serial console redirection is considered
a console input device if enabled.
This beep code is only an information.
6
Flash update is failed
A processing bar and an error message is
displayed on the screen.
This beep code is only an information.
8
Platform PCI resource
requirements cannot be
met
▶
Check the connection of your
expansion card whether it is installed in
a correct slot.
▶
Enter the BIOS setup menu.
▶
Open the
Advanced
menu.
▶
Check in the
PCI Subsystem Settings
the parameter
Above 4G Decoding
.
This parameter must be set to
Enabled
.
Appendix A
RX2520 M5
Upgrade and Maintenance Manual
457
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...