Push the dummy module into the empty bay until it engages.
Concluding steps
▶
If applicable,
"Switching on the server" on page 57
.
7.5.7
Replacing a 2.5-inch PCIe SSD module
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
– Installation frame included: tool-less
– Installation frame excluded: Phillips PH1 / (+) No. 1 screw driver
This procedure is valid, if the PCIe SSD module is controlled by an
onboard controller or by a Retimer card. For more information, see the
"NVMe User Guide".
If the PCIe SSD module is controlled by a RAID controller of the PRAID
EP5x0i family, the PCIe SSD module can be installed during operation
(hot-plug), see
"Removing 2.5-inch HDD/SSD modules" on page 175
.
CAUTION
All HDD/SSD modules (drives) must be uniquely identified so that they
can be reinstalled in their original bays later. If this is not done, existing
data can be lost.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
Identify the physical location of the PCIe SSD module, see
▶
Prepare the removing of the PCIe SSD module, see the "NVMe User
Guide".
▶
Depending on your OS (see the "NVMe User Guide"):
Hard disk drive (HDD) / solid state disk (SSD)
184
Upgrade and Maintenance Manual
RX2520 M5
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...