"Getting access to the component" on page 47
▶
Release all HDD modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD module" on page 136
.
CAUTION
The HDD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page 132
▶
"Removing the air duct" on page 58
▶
"Removing the fan holder" on page 60
.
Removing a 3.5-inch HDD backplane
Note on removing a 3.5-inch HDD backplane
For easier access to the backplane screws at the bottom side, it could be
helpful to remove the CPU with the heat sink, see
.
CAUTION
Ensure that the CPU socket will not be damaged!
Best practice is to use a short screw driver:
Figure 51: Short screw driver
Hard disk drive (HDD) / solid state disk (SSD)
140
Upgrade and Maintenance Manual
RX2520 M5
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...