13
Front panel
13.1
Safety notes
CAUTION
▶
When inserting the front panel module into the server, ensure not to
pinch or strain any connected cables.
▶
Circuit boards and soldered parts of internal options are exposed
and can be damaged by static electricity. Always discharge static
build-up (e.g. by touching a grounded object) before handling
electrostatic-sensitive devices (ESDs).
▶
Do not touch the circuitry on boards or soldered parts. Hold circuit
boards by their metallic areas or edges.
▶
"Important information" on page 29
.
13.2
Basic information
In case of a defective ambient temperature sensor, please replace the front
panel.
Front panel module
The front panel module consists of a holder and a front panel board. These
components are already pre-assembled. The USB connector of the front USB
cable must be installed in the dependant recesses of the holder.
Front panel on QRL (24x 2.5-inch and 12x 3.5-inch HDD configuration)
The front panel on QRL (Quick Release Lever) is only available for the servers
with a 24x 2.5-inch HDD configuration and 12x 3.5-inch HDD configuration.
The front panel is installed on the right side ear. A flat cable is used for
connection to the system board.
RX2520 M5
Upgrade and Maintenance Manual
345
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...