16.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
1 CPU with CPU heat
sink
installed in CPU slot CPU 1
1 memory module
installed in DIMM slot 1A
Front panel module
1 PSU
installed in PSU bay PSU 1
Table 5: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 6: Minimum startup configuration - cables
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
Take the system down to its minimum startup configuration.
▶
"Connecting the power cord" on page 56
.
▶
Connect a display to the server.
▶
Switch on the server, see
"Switching on the server" on page 57
.
Appendix A
460
Upgrade and Maintenance Manual
RX2520 M5
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...