Replacing the iRMC microSD card
▶
Remove the defective iRMC microSD card, see
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
▶
After removing the iRMC microSD card, hand the card over to
the customer.
▶
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
▶
Install the new iRMC microSD card, see
"Installing the iRMC microSD card"
.
Concluding steps
▶
▶
"Connecting the power cord" on page 56
▶
"Switching on the server" on page 57
15.6
M.2 SSD
15.6.1
Slots and bolts for M.2 SSDs
The system board offers two M.2 slots (Key M) with support for 42 mm, 60 mm,
80 mm and 110 mm long M.2 SSDs. With the M.2 SSD an internal SSD is
offered. This SSD can be configured as a boot device or data storage device.
System board and components
RX2520 M5
Upgrade and Maintenance Manual
405
Summary of Contents for PRIMERGY RX2520 M5
Page 100: ...Basic software procedures 100 Upgrade and Maintenance Manual RX2520 M5 ...
Page 122: ...Power supply unit PSU 122 Upgrade and Maintenance Manual RX2520 M5 ...
Page 290: ...Processor CPU 290 Upgrade and Maintenance Manual RX2520 M5 ...
Page 344: ...Accessible drives 344 Upgrade and Maintenance Manual RX2520 M5 ...
Page 378: ...Front panel 378 Upgrade and Maintenance Manual RX2520 M5 ...
Page 386: ...Serial interface 386 Upgrade and Maintenance Manual RX2520 M5 ...
Page 432: ...System board and components 432 Upgrade and Maintenance Manual RX2520 M5 ...
Page 462: ...Appendix A 462 Upgrade and Maintenance Manual RX2520 M5 ...
Page 503: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...