Remove the protective plastic cover from the CPU socket of the new system
board and fit it onto the socket of the defective system board which will be
sent back to spares.
Returned system boards without this cover probably have to be
scrapped.
▶
Remove the TPM, see
"Removing the TPM" on page 299
.
Installing the new system board
▶
Confirm that the CPU model number printed on the top of the CPU fits with
the requirements.
▶
Install the CPU on the new system board, see
.
▶
Check the settings on the new system board, see
.
▶
Install the heat sink, see
"Installing the heat sink" on page 252
.
▶
Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel, see
▶
Lower the system board carefully into the chassis.
▶
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion.
▶
Fasten the system board with the eight screws, see
.
System board and components
RX1330 M4
Upgrade and Maintenance Manual
331