Tools:
tool-less
CAUTION
▶
When replacing a PSU in a non-redundant PSU configuration, the
server must be switched off first.
▶
Replace the PSU after specifying the one that breaks down at work
by revitalization.
Note for servers using CMA (Cable Management Arm)
Regarding of removing PSUs, additional tasks are needed, due to an
interference between CMA and the PSUs.
▶
If applicable, open the CMA of the server below to get enough space at the
under side of your server.
▶
Unlock the CMA stopper of the server below.
▶
Pull out the CMA of the server below to the rear side.
▶
Push the lock spring inward to unlock the CMA bracket, see
.
▶
Remove the CMA.
▶
Hold the CMA including cables in the one hand.
▶
Remove the PSU (see
) and install the new PSU carefully.
▶
Mount the complete assembly (CMA bracket and the CMA) again into the
rail.
▶
If applicable, close the CMA of the server below.
Preliminary steps
▶
"Locating the defective server" on page 43
▶
Check which PSU is defective.
PSU is defective when the PSU status indicator lights orange. For more
information, see
"Indicators on the hot-plug HDD/SSD module" on page 351
.
▶
Only when replacing a PSU in a non-redundant configuration:
Power supply unit (PSU)
RX1330 M4
Upgrade and Maintenance Manual
113
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...