15.5.4
Replacing the iRMC microSD card
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
tool-less
Preliminary steps
▶
"Locating the defective server" on page 43
▶
"Shutting down the server" on page 45
.
▶
"Disconnecting the power cord" on page 46
.
▶
"Getting access to the component" on page 48
▶
"Removing the air duct" on page 63
.
▶
Remove the riser module 1, see
"Removing a riser module" on page 59
Replacing the iRMC microSD card
▶
Remove the defective iRMC microSD card, see
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
▶
After removing the iRMC microSD card, hand the card over to
the customer.
▶
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
▶
Install the new iRMC microSD card, see
"Installing the iRMC microSD card"
.
System board and components
RX1330 M4
Upgrade and Maintenance Manual
309
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...