Select
Reset
from the
Watchdog Action
list.
▶
Click
Apply
for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
5.3.9
Enabling replaced components in the BIOS
When a CPU, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the BIOS. The server will then
reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be
reenabled in the BIOS.
▶
Enter the BIOS.
▶
Select the
Advanced
menu.
▶
Select the status menu of the desired component:
▶
Select
CPU Status
for CPUs.
This option is only available for multi-processor systems.
▶
Select
Memory Status
for memory modules.
▶
Select
PCI Status
for expansion cards.
▶
Reset replaced components to
Enable
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.3.10
Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will
be disabled. As a result, the current operation mode (e.g. Mirrored Channel
mode) may no longer be available due to a lack of identical memory module
Basic software procedures
RX1330 M4
Upgrade and Maintenance Manual
81
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...