Release all HDD modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD module" on page 144
.
CAUTION
The HDD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 3.5-inch HDD dummy module" on page 141
Removing the defective 3.5-inch HDD backplane
▶
Disconnect all cables from the HDD backplane.
▶
If applicable, disconnect the ODD power and SATA cable to make room to
remove the HDD backplane easier.
Figure 66: Removing the 3.5-inch HDD backplane
▶
Pull the HDD backplane upward until the three hooks disengage (see
circles).
▶
Take out the HDD backplane.
Installing the new 3.5-inch HDD backplane
A
A
A
Figure 67: Installing the 3.5-inch HDD backplane
Hard disk drive (HDD) / solid state drive (SSD)
148
Upgrade and Maintenance Manual
RX1330 M4