16.2.4
Acoustic indicators
PEI Beep Codes
Pre-EFI Initialization (PEI) - memory Initialization (bootblock)
# of
Beep
Description
Action
1
Memory not installed
▶
Check if the memory module is
installed.
▶
Check if the memory module is
installed correctly.
2
Recovery started
Recovery procedure is initialized by
jumper settings on the system board and
announced with two beep.
This is only an information.
4
Recovery failed
▶
Restart the recovery procedure again.
▶
If the same beep code sounds again,
replace the system board.
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
Appendix A
RX1330 M4
Upgrade and Maintenance Manual
359
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...