"Switching on the server" on page 58
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed
.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
●
Restart your server.
●
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
●
If a password is assigned, enter the password and press [Enter].
●
Select the
Save & Exit
menu.
●
Select
Save Changes and Exit
or
Save Changes and Reset
.
●
Verify that the Global Error indicator stops flashing.
▶
"Resetting the error status after replacing memory modules or CPU" on
page 76
▶
"Enabling replaced components in the BIOS" on page 81
▶
"Resuming BitLocker functionality" on page 86
.
11.4
Replacing the heat sink
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Depending on ATD support, there are different heat sinks available, see
" Types of heat sinks (A)" on page 242
Processor (CPU)
RX1330 M4
Upgrade and Maintenance Manual
253