Resetting the boot retry counter using iRMC web interface
▶
Enter the ServerView iRMC web interface.
▶
Select the
Server Management
menu.
▶
The following boot retry counter settings are available under
ASR&R
Options
:
▶
Under
Retry counter max
specify the maximum number of attempts to
boot the OS (0 to 7).
▶
Under
Retry counter
the current number of remaining boot attempts is
displayed. Overwrite this value with the maximum number of boot
attempts specified above in order to reset the boot retry counter.
▶
Click
Apply
for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
5.3.7
Resetting the error status after replacing memory
modules or CPU
5.3.7.1
Resetting the error status after replacing memory modules
In case of a memory error, an error counter may be set for the defective
memory module.
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
Using ServerView Maintenance Tools (Windows only)
▶
Launch the ServerView Maintenance Tools:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
▶
Choose the
Memory
status tab.
Basic software procedures
76
Upgrade and Maintenance Manual
RX1330 M4
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...