Installing the new 10x 2.5-inch HDD backplane
Figure 90: Installing the 10x 2.5-inch HDD backplane
▶
Position the HDD backplane on the six hooks (see circles).
▶
Push the HDD backplane downward. Make sure that the HDD backplane fits
into the guides (A).
Installing the SAS expander board
Figure 91: Installing the SAS expander board (A)
▶
Insert the SAS expander board into the two connectors of the HDD
backplane.
CAUTION
▶
Lift up the SAS expander board while inserting it in order to
prevent the components to be damaged by the stand-offs of the
chassis.
Hard disk drive (HDD) / solid state drive (SSD)
170
Upgrade and Maintenance Manual
RX1330 M4