RAID level
Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
RAID 1
RAID 5
Removing an HDD/SSD module from a RAID 1 or
RAID 5 array will not result in data loss. However,
the removed drive needs to be replaced
immediately by an HDD/SSD module of the same
or larger capacity.
After replacing the HDD/SSD module,
RAID rebuild will be performed as a
background process, see
RAID array rebuild" on page 87
.
In order to permanently remove an operational HDD/SSD module that is part of
a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
Removing a 2.5-inch HDD/SSD module
▶
Pinch the green locking clips and open the locking lever, see
▶
Pull the HDD/SSD module out a few centimeters.
▶
Wait about 30 seconds to allow the HDD to spin down.
This is not necessary when removing an SSD.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Hard disk drive (HDD) / solid state drive (SSD)
156
Upgrade and Maintenance Manual
RX1330 M4
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...