If the server has been powered off (power plugs must be disconnected) it is
possible to indicate the faulty component by pressing the indicate CSS button.
The LEDs have the following meaning:
Indicator
Status
Description
A -
Identification
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC S5
web interface or the ID button on the front
panel for easy identification.
flashing blue
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
B - CSS
(Customer Self
Service)
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
flashing orange CSS component failure detected.
C - GEL
(Global Error
LED)
off
No critical event detected (non-CSS
component).
orange on
Prefailure event detected (non-CSS
component).
flashing orange
Non-CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server management
software
F - Controller
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
Appendix A
RX1330 M4
Upgrade and Maintenance Manual
345
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...