CAUTION
▶
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the
corresponding HDD module, see
"Indicators on the hot-plug HDD/
.
▶
An HDD module can be replaced while the system is in operation.
RAID configuration with a RAID controller:
●
Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
●
Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are
supported for internal HDD configurations.
●
Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
▶
An HDD module can be replaced while the system is in operation.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
▶
All HDD modules (drives) must be uniquely identified so that they
can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Locating the defective component" on page 44
.
Hard disk drive (HDD) / solid state drive (SSD)
146
Upgrade and Maintenance Manual
RX1330 M4
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...