CAUTION
All data on all HDDs in the array will be lost when deleting the RAID
array!
▶
Be sure to back up your data before deleting a RAID array.
▶
For more information, see the "ServerView Suite RAID
Management" user guide.
Removing a 3.5-inch HDD module
▶
Pinch the green locking clips and open the locking lever, see
▶
Pull the HDD module out a few centimeters.
▶
Wait about 30 seconds to allow the HDD to spin down.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
▶
Pull the HDD module completely out of its bay.
Installing a 3.5-inch dummy module
CAUTION
▶
If the removed HDD module is not replaced immediately, always
replace a dummy module into the unused HDD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 65: Installing the 3.5-inch dummy module
▶
Push the dummy module into the empty bay until it engages.
Hard disk drive (HDD) / solid state drive (SSD)
144
Upgrade and Maintenance Manual
RX1330 M4