Installing the heat sink
Figure 163: Installing the heat sink
▶
Ensure that the heat sink cooling fins match the direction of the airflow!
▶
Carefully seat the heat sink on the four threaded holes as shown.
CAUTION
▶
Ensure that the screws on the heat sink are properly seated on
the threaded holes.
▶
Fasten it in a crossover pattern with four screws according to the numbering
(torque: 0.6 Nm, not applicable for Japan).
Notice the position of the air flow label.
Concluding steps
▶
"Installing the air duct" on page 64
▶
.
▶