MB95630H Series
296
FUJITSU SEMICONDUCTOR LIMITED
MN702-00009-2v0-E
CHAPTER 17 CLOCK SUPERVISOR COUNTER
17.3 Operations
Table 17.3-1 is calculated by the following equation:
If the time-base timer interrupt is used to make the clock supervisor counter wait for the
oscillation stabilization time, please satisfy the following condition:
Time-base Timer Interval > Main Oscillation / Suboscillation Stabilization Time
×
1.05
e.g. F
CH
= 4 MHz, F
CRH
= 1 MHz, MWT[3:0] = 0b1111 (in WATR register)
Time-base Timer Interval >
TBC[3:0] = 0b0110 (2
13
×
1/F
CRH
)
Notes:
•
See "7.1 Overview" for time-base timer interval settings.
•
See "3.3.3 Oscillation Stabilization Wait Time Setting Register (WATR)" for main/
sub-oscillation stabilization time settings.
Counter value =
2
3
×
1/F
CRH
(TBTSEL=000)
2
5
×
1/F
CRH
(TBTSEL=001)
2
7
×
1/F
CRH
(TBTSEL=010)
2
9
×
1/F
CRH
(TBTSEL=011)
2
11
×
1/F
CRH
(TBTSEL=100)
2
13
×
1/F
CRH
(TBTSEL=101)
2
15
×
1/F
CRH
(TBTSEL=110)
2
17
×
1/F
CRH
(TBTSEL=111)
×
Main/Sub-Oscillation Clock Frequency
2
±
1 (Measurement error)
*Omit the decimal places of “Counter value”.
Selected time-base
timer interval
Within this period, the “Counter value” in the above equation is
counted by the main/sub oscillation clock.
2
14
2
)
–
(
4
10
6
×
-----------------------
1.05
4.3 ms
≈
×