MB95630H Series
412
FUJITSU SEMICONDUCTOR LIMITED
MN702-00009-2v0-E
CHAPTER 21 MULTI-PULSE GENERATOR
21.5 Operations
21.5.4.5
At Position Detection or Timer Underflow
The output timing changes of the operation of the Position Detection or Reload
Timer underflow are shown in Figure 21.5-20 and Figure 21.5-21. This operation
mode is selected by setting the OPS[2:0] = 0b100.
■
Timing Generated by Position Detection or Timer Underflow
Figure 21.5-20 Timing Generated by Position Detection or Timer Underflow
0b0100 0b0110 0b0010 0b0011 0b0001 0b0101 0b1010 0b1011
OPT5
OPT4
OPT3
OPT2
OPT1
OPT0
16-bit reload timer underflow occurs.
Write signal is generated when theres is a comparison match between RDA[2:0] and
SNI2-SNI0 or any effective edge input at SNI2-SNI0. The comparison is triggered by the
input edge position detection input terminal SNIx.
SNI2
SNI1
SNI0
Timer
starts
BNKF,
RDA2,
RDA1,
RDA0
No. 0
No. 4
No. 6
No. 2
No. 3
No. 1
No. 5
No. A