130
FMPC
NOTE:
Do not try to click the [Start] button other than one
for “PSR”.
5
Press the [Enter] key on the printer operation
panel.
• The countdown of ten seconds starts.
6
Insert the PSR nozzle into the measuring
cylinder during the countdown, and hold the
cylinder at the same height as the nozzle setting
position.
The countdown stops and the PSR pump starts to
discharge.
• The alarm beeps twice when the discharging is
completed.
7
Return the nozzle to the PSR sub-tank.
8
Put the measuring cylinder on a horizontal
surface, read the liquid amount and record it.
9
Dispose of the liquid in the measuring cylinder.
10
Enter the measured value in the “Measured vale”
box for “PSR”.
11
Click the [OK] button.
• Operation returns to the menu screen.
12
Reinstall the water supply port inner cover and
close the supply port door.
# No.2 MEASURE
# START
[YES] ?
PSR Replenisher
Nozzle
Measuring Cylinder
L
2
1150
distributed by www.minilablaser.com