105
FMPC
8.2.25 Processing Temperature Setting
(463)
[Selection]
“4 Setup and Maintenance” - “6 Processor
Adjustment/Maintenance” - “3 Processing
Temperature Setting”
[Procedure]
Set the processing temperatures.
1
Enter the numerical values of the “P1”, “P2” and
“PS” processing temperatures.
2
Click [OK].
• Operation returns to the “4 Setup and
Maintenance” screen.
8.2.26 Replenisher Rate Setup (464)
[Selection]
“4 Setup and Maintenance” - “6 Processor
Adjustment/Maintenance” - “4 Replenisher Rate
Setting”
[Procedure]
Set the replenishment amount.
1
Enter the numerical values of the “P1-R”, “P2-R”
and “PS-R” replenishment amount.
2
Click [OK].
• Operation returns to the “4 Setup and
Maintenance” screen.
Range
Default Value
P1
30.0 to 40.0
38.5
P2
30.0 to 40.0
38.0
PS
30.0 to 40.0
38.0
Range
Default Value
P1-R
30.0 to 200.0
45.0
P2-R
20.0 to 300.0
35.0
PS-R
100.0 to 300.0
150.0
distributed by www.minilablaser.com