101
FMPC
8.2.16 G, B Laser (SHG) Optimal
Temperature Setup (454)
[Selection]
“4 Setup and Maintenance” - “5 Printer Adjustment/
Maintenance” - “4 G, B Laser (SHG) Optimal
Temperature Setup”
[Procedure]
Setup the G, B laser (SHG) optimal temperature.
NOTE:
Perform this menu two hours after the LD has been
ON. This provides sufficient time for the laser to
warm up.
1
Click [Enter].
• The optimal temperature setup is started, and
the result is displayed after 5 minutes.
2
Click [End].
• Operation returns to the “4 Setup and
Maintenance” screen.
8.2.17 Paper Feed (455)
[Selection]
“4 Setup and Maintenance” - “5 Printer Adjustment/
Maintenance” - “5 Paper Feed”
[Procedure]
Paper is fed without printing.
1
Set the number of prints, feed length and select
magazine.
Quantity
: 1 to 999
Feed Length : 82.5 to 381.0
Magazine
: Upper/Lower
2
Click [OK].
• Paper is fed.
3
Click [End].
• Operation returns to the “4 Setup and
Maintenance” screen.
distributed by www.minilablaser.com