![Fuji Electric FCX-AII-V4 Series User Manual And Service Instructions Download Page 52](http://html1.mh-extra.com/html/fuji-electric/fcx-aii-v4-series/fcx-aii-v4-series_user-manual-and-service-instructions_2341969052.webp)
52
TN4FCXA2
j
-EDF-
E
Menu E: Operation of the printer
(PRINT)
If the printer is connected, the parameters of the
transmitter can be printed in the configuration
menu “E:PRINT” (print). If the printer is not
connected, “NO CONNECTION” appears on
the display.
<ENT> must be pressed to print data and
enter the date and the hour. After validation by
<ENT>, the printing takes place while “PRINT
OUT” is displayed. <CL> returns to the output
position.
If the printing is finished, “PRINT OUT END”
appears on the display. Then the paper can
be advanced by <INC> or the configuration
menu “E:PRINT” can be returned to by pressing
<CL>.
Note
:
9 parameters are printed, in addition to the
date and time of printing:
(TAG NO, TYPE, URL, RANGE, DAMPING,
BURN OUT, DATA, TEMP and RAS)
E-2: PRINT OUT
E: PRINT
< INC >
E-1: PRINT
DATE
TIME
< CL >
E-3: PRINT OUT
PRINT OUT END
< INC >PAPER FEED
< CL >
CL
INC
INC
CL
ENT
INC
ENT
(Indicated when the printer unit is active)
YY : MM : DD
HH : MM
Paper Feed (Printer)
Without Printer Unit
E: PRINT
< INC >
NO CONNECTION
With Printer Unit
< ENT >
< ENT >
Time (Hour, Minute)
Set Year/Month/Date
F : XMTR EXT.SW
D : SELF CHECK
This menu allows you to lock or unlock the
zero adjustment using the external screw.
Pressing the <1> key blocks any adjustment
by the external screws.
Pressing the <2> key authorises this
manipulation.
Menu F: Blocking the setting by means
of external keys (XMTR EXT.SW)
2
F-1: XMTR EXT. SW
F-2: XMTR EXT. SW
CHANGE
3
F-2: XMTR EXT. SW
CHANGE
4
< 1 > INHIBIT
< ENT >
INHIBIT
INC
F: XMTR EXT. SW
1
< INC > < CHANGE >
CL
CL
1
< 2 > ENABLE
< 1 > < 2 > < CL >
CHNG OK? < ENT/CL >
F-3: XMTR EXT. SW
WRITE
5
INHIBIT
CHNG
CL
ENT
ENT
ENABLE
INHIBIT
< CL >
F : XMTR DISPLAY
E : PRINT