![Fuji Electric FCX-AII-V4 Series User Manual And Service Instructions Download Page 12](http://html1.mh-extra.com/html/fuji-electric/fcx-aii-v4-series/fcx-aii-v4-series_user-manual-and-service-instructions_2341969012.webp)
12
TN4FCXA2
j
-EDF-
E
INSTALLATION AND CONNECTIONS
3
3.1 Installation
When unpacking, check the transmitter and any accessories.
Before installation, the customer must check the compatibility of the materials in contact with
the process to be measured.
The transmitter can be fixed on a 2” mounting tube or against a wall.
The FKE level transmitter is equipped with a flange to connect directly to the flange mechanism.
Note):
In the case of wall mounting, the fixing screws (M8) must be provided by the user.
See the “Technical Specifications” for blockage of the transmitters.
For a process involving explosive gas, an ADF certified transmitter (explosion
protected) must be fitted, otherwise there is a risk of serious accidents
(explosion, fire, etc).
DANGER
If the transmitter is not mounted quickly after the delivery, it should preferably
be left in its packaging and stored under normal ambient temperature and
humidity conditions (25°C, 60% HR).
Type of
Temperature
Temperature Max
MWP - Pressure
Technical
transmitter
Limits
Limits
measurement Max line
specifications
Atmospheric
Process
range
(static pressure)
Differential
see note*
-40 to 120°C 10 mbar
-1 to 32 bar
pressure
(silicone oil)
60 mbar
-1 to 100 bar
320 mbar
-1 to 160bar
-20 to +80°C
(option: 420 bar)
FDSF6-114
(fluoridated oil) 1300 mbar
-1 to 160bar
(option : 420 bar)
5000 mbar
-1 to 160bar
(option : 420 bar)
30000 mbar
-1 to 160bar
(option : 300 bar)
Relative
see note*
-40 to 120°C 1.3 bar,
1.3 bar
pressure
(silicone oil)
5 bar
5 bar
30 bar
30 bar
FDSF5-80
-20 to +80°C
100 bar
100 bar
(fluoridated oil) 500 bar
500 bar
Absolute
-25 to 55°C
-40 to +85° C 0.16 bar abs 0.64 bar abs
pressure
(silicone oil)
1.3 bar abs
1.3 bar abs
FDSF5-79
-20 to +80°C
5 bar abs
5 bar abs
(fluoridated oil) 30 bar abs
30 bar abs
Level and
-25 to 55°C
320 mbar
as per PN/lbs
FDSF6-03
separators
see note*
1300 mbar
of separator
FDSF7-60
5000 mbar
30000 mbar
INDICATION
*
Refer to the “technical specification” for all details regarding the process temperature limits of the transmitters.
For specific transmitters with static pressures > 420 bar, inquire with Fuji Electric France.
Protect the transmitter by a pressure safety element depending on its
application. Install the transmitter at a distance from the measuring point if
the process temperature is too high.
INDICATION