Install the AP433e
33
13.
Check that the AP433e is operating correctly before replacing the ceiling tile. Verify cor-
rect operating using the LEDs, as shown in
.
Mount AP433e on a Dropped Ceiling Bevel Tile
The mounting procedure for a ceiling that has recessed supports and lowered tiles is similar to
that of mounting on a suspended ceiling. However, this procedure requires a specialized
mounting bracket (MNT-SCRMKIT-03), as shown in
.
Figure 14:
Dropped Bevel Tile Mounting Bracket
1.
Remove the ceiling tile alongside which the AP will be mounted.
2.
Be sure that AP433e is not locked by inserting the locking key into the Unlock mechanism
as shown in
below.
Use a shielded Cat 5e (or greater) Ethernet cable in order to comply with international electromagnetic
emissions limits.