
EtherScope™ Series II
Getting Started Guide
120
Problem
: The instrument does not power on.
Suggestion
: Connect the instrument to the AC adapter. If
the instrument powers on only when connected to the
AC adapter, the internal battery may be completely
discharged. Recharge the battery.
Problem
: The user interface does not appear.
Suggestion
: The Test Results screen should be displayed
after you turn on the instrument.
If the screen does not display, press and hold the On/Off
button for six seconds to completely shut down the
instrument. Then, press the On/Off button again to
power the instrument back on.
Problem
: The IP Discovery and/or Tools results screens are
not displaying the expected results.
Suggestion
: Check the following:
•
Does the instrument have a valid IP address? Select
Connection on the Test Results
screen to see if the
instrument is configured with a valid IP address.
•
Verify that the DHCP capability on the Instrument
Settings—TCP/IP screen is not disabled. If an IP
address is entered manually, it must not be an
address within the local subnet.