Firmware Upgrade
Note
The latest version of the firmware is available for download on the Fluke
web page,
http://www.fluke.com
. See the Main Product and Support pages
to access the download link.
W
Caution
The instrument may cease functioning if its power is
interrupted during the firmware install operation. Do not shut
off the power during the firmware installation.
The firmware within the Instrument is stored in flash and can be restored or upgraded by
transmission over a serial link from a PC to the Instrument.
Equipment Required for the Restore or Upgrade
The following items are required to perform a firmware restore or upgrade:
•
A PC running Microsoft Windows 2000 or Microsoft Windows XP. This computer
must have either a 9-pin serial port (RS232) or a USB port.
•
The install software, either an upgraded version or the original firmware version
supplied with the Instrument on the Product Manuals and Software CD.
•
Using the serial port requires a null modem serial cable with a female DB-9
connector at each end. The pin assignments of the serial cable (RS232) are as
follows:
•
PC pin 2 <=> Instrument pin 3
•
PC pin 3 <=> Instrument pin 2
•
PC pin 5 <=> Instrument pin 5
It is recommended that only the above pins are connected
The use of a USB port requires a USB-to-serial converter with a male DB-9 RS232
connector. The above serial cable is used to connect the USB converter to the
Instrument. If the USB-to-serial converter needs a software driver, install the driver
on the PC before beginning the firmware upgrade.
Installing the Firmware
Use the following 3-stage procedure to install the firmware:
•
Stage 1 - Configure the Instrument for upgrade.
•
Stage 2 - Upload the firmware.
•
Stage 3 - Restore the Instrument to normal operation.
Stage 1
1.
Power off the Instrument.
2.
Connect the Instrument and PC together using the RS232 cable (the Instrument’s
RS232 port is on the rear panel).
Or, if using USB, connect together the PC, and the USB converter using a USB
cable, and then connect together the USB converter and the Instrument using the
RS232 cable.
Summary of Contents for 9640A Series
Page 8: ......
Page 16: ...9640A Instruction Manual viii...
Page 22: ...9640A Instruction Manual 1 2...
Page 40: ...9640A Instruction Manual 2 2...
Page 108: ...9640A Instruction Manual 4A 2...
Page 138: ...9640A Instruction Manual 4C 2...
Page 164: ...9640A Instruction Manual 4D 2...
Page 168: ...9640A Instruction Manual 4D 6...
Page 170: ...9640A Instruction Manual 4E 2...
Page 174: ...9640A Instruction Manual 4E 6...
Page 176: ...9640A Instruction Manual 4F 2...
Page 184: ...9640A Instruction Manual 4F 10...
Page 186: ...9640A Instruction Manual 4G 2...
Page 190: ...9640A Instruction Manual 4G 6...
Page 192: ...9640A Instruction Manual 5 2...
Page 272: ...9640A Instruction Manual 5 82...
Page 274: ...9640A Instruction Manual 6 2...
Page 284: ...9640A Instruction Manual 7 2...
Page 310: ...9640A Instruction Manual 8 2...
Page 316: ...9640A Instruction Manual 8 8...
Page 320: ...9640A Instruction Manual A 4...