FLIR Detection
5. FLIR identiFINDER R300 Alarms
5.2
Neutron Alarms
Available only for variants equipped with a neutron detector.
The FLIR identiFINDER R300 continuously compares the number of detected neutrons per given
period against thresholds you can specify for warnings and alarms (see
6.35
, p.
163
).
When a threshold is exceeded, an appropriate warning or alarm is raised and reported visually
(Figure
104
, p.
101
). The appropriate behavior of the annunciators is detailed in Figure
105
, p.
101
.
Figure 104.
Alarm display: Neutron alarm
Blue LED
Beeper
Vibrator
Blue LED
Beeper
Vibrator
clock
1 s
1 s
1 s
Warning
Alarm
Figure 105.
Neutron incidents as announced by the blue LED, beeper, and vibrator
5.3
Sigma Noti cations
The FLIR identiFINDER R300 continuously monitors the radiation level and uses a smart algorithm
to detect unusual increases. These events are announced as “
𝜎
noti ication” in the display’s title bar
(Figure
106
, p.
102
) and, optionally, via beeper and vibrator.
identiFINDER
®
R300/en/2014.4(13623)/Feb2015
101