Installation Instructions
9.12.14
Kapitel/Chapter 7: Installation Instructions - Seite/Page 93
Fig. 7.10.1-2: Negative Battery Cable
Negative battery cable
The negative (-) battery cable is connected to the engine
foot.
Note! The battery negative pole may not be connected
with the boat ground or with the protective grounding of
the 120 V installation!
Fig. 7.10.1-3: DC-Relay
DC-Relay
The Panda generators 8000 to 30 are equipped with various
DC-relays, which can be found under the terminal strip. The
various relays have the following tasks (also see the DC
circuit diagram)
1. Starter motor relay
2. Pre-glow relay (glow plugs)
3. Fuel pump relay
Sample Picture - See wiring diagram
Fig. 7.10.1-4: DC Starter Motor
DC Starter Motor
All Panda generators are equipped with an independent DC
starter motor.
1. Solenoid switch for starter motor
2. Starter motor
1
2
3
1
2