Maintenance Instructions
9.12.14
Kapitel/Chapter 9: Maintenance Instructions - Seite/Page 179
9.28 Replacing the Glow Plugs
NOTE:Representative procedure
The described procedure is representative for Fischer Panda
generators. The original location of the item must be taken
from the generator description of this manual. All
replacements and repairs should be done by a trained
person.
ATTENTION!
Ensure that the generator cannot be started up
accidentally. Remove battery main switch.
Fig. 9.28-1: Glow plugs
1. Open the capsule.
01. Glow plugs
Fig. 9.28-2: Glow plugs
Figures similar!
2. Remove the three hex screws using a size 7 mm socket
wrench .
01
01
01
7