Maintenance Instructions
Seite/Page 122 - Kaptitel/Chapter 9: Maintenance Instructions
9.12.14
Fig. 9.10.1.3-8: Hold up the driving shaft
Hold up the driving shaft.
Sample Picture
Fig. 9.10.1.3-9: Remove tools and markings
• Remove tools.
• Remove markings.
• Mount cooling disc (if existent).
• Mount presilencer and circuit points.
• Refill cooling water and vent cooling water circuit (see
generator manual.
• Remove starting lock.
• Reconnect starter battery.
• Run generator 3 to 5 minutes.
• Mount casing.
Sample Picture
9.11 Checking the oil level of the generator end bearing at Fischer Panda
generators
The oil level check is a visual check. Older generators are equipped with an sight glass, newer ones with an sight
hose.