APPENDIX B 

 

UL S2203 

Cheetah Xi 50 Installation Manual 

B-1 

FM 

 

P/N: 06-369 

Rev 6, 09/2015

 

The  “System Operation Posting” shown on the following pages provides  a brief summary of the basic 
operation of the Cheetah Xi 50 system.  The operational posting can also be downloaded from Fike Forums 
web page (document P/N 06-650).  For a detailed description of the operation of the Cheetah Xi 50 system, 
refer to Fike document 06-369-2, “Cheetah Xi 50 Operation and Maintenance Manual” for more details. 

The completed  “System Operation Posting” shall either be mounted on the cabinet front or framed and 
located adjacent to the control unit.  

Summary of Contents for 10-071

Page 1: ...Installation Manual P N 06 369 Rev 6 September 2015 10 071 Cheetah Xi 50 Addressable Fire Suppression Control System ...

Page 2: ...nty returns must be returned from an authorized Fike Distributor Contact Fike s Marketing department for further warranty information Fike maintains a repair department that is available to repair and return existing electronic components or exchange purchase previously repaired inventory component advance replacement All returns must be approved prior to return A Material Return Authorization MRA...

Page 3: ... 4 7 Appendix 08 2008 Added Remote 20 Zone Annunciator 2 Sections 1 2 3 6 03 2010 Added IRM Compatibility 3 All Sections 04 2012 Separated manual into individual Installation and Operation Programming manuals updated list of compatible devices added FAAST detector 4 All Sections 08 2014 Added FAAST XT aspirating smoke detector 5 Section 3 9 6 and Appendix A 02 2015 Added solenoid protection assemb...

Page 4: ...municator Transmitter DACT 3 8 3 4 1 DACT Keypad Programmer 3 8 3 5 Peripheral Bus Devices 3 9 3 5 1 Fourteen Button Remote Display Unit 3 9 3 5 2 Ten Button Remote Display Unit 3 9 3 5 3 Two Button Remote Display Unit 3 10 3 5 4 Ethernet Module 3 10 3 5 5 Multi Interface Module MIM 3 10 3 5 6 Intelligent Graphic Annunciator 3 11 3 5 7 Twenty Zone Remote Annunciator 3 11 3 5 8 Relay Control Assemb...

Page 5: ...d Battery Enclosures 3 24 3 12 1 Battery Assemblies 3 24 3 12 2 Batteries 3 24 3 12 3 Battery Enclosures 3 24 3 12 3 1 33 AH Battery Enclosure 3 24 3 12 3 2 75 AH Battery Enclosure 3 24 4 0 Installation 4 1 4 1 System Installation Sequence 4 1 4 2 Select the Enclosure Mounting Location 4 1 4 3 Select the Enclosure Mounting Option 4 2 4 4 Mount the Enclosure 4 2 4 5 Wire Selection 4 3 4 6 Circuit C...

Page 6: ... 3 Class X 4 16 4 13 6 4 Detector Base Wiring 4 16 4 13 7 Notification Appliance Circuit Wiring 4 17 4 14 Initial Power Up with Field Wiring Connected 4 17 4 15 Configure System 4 18 4 16 Acceptance Test 4 18 4 17 Install the Dead Front Panel 4 18 Appendix A Battery Calculation Form A 1 Appendix B System Operation Posting B 1 Appendix C Compatible Components C 1 Appendix D Battery Cutoff D 1 ...

Page 7: ...with Dead Front 3 7 3 12 DACT 3 8 3 13 DACT Programmer 3 8 3 14 Fourteen Button Remote Display Unit 3 9 3 15 Ten Button Remote Display Unit 3 9 3 16 Two Button Remote Display Unit 3 10 3 17 Ethernet Module 3 10 3 18 Multi Interface Module 3 10 3 19 LED Graphic Annunciator Intelligent 3 11 3 20 Twenty Zone Remote Annunciator 3 11 3 21 Relay Control Assembly 3 11 3 22 Relay Card 3 12 3 23 Class A Pe...

Page 8: ...r Transformer Wiring 4 6 4 6 DACT Mounting Location 4 7 4 7 DACT Mounting 4 7 4 8 Controller Mounting Location 4 8 4 9 Controller Mounting 4 8 4 10 AC Power Connections 4 9 4 11 Battery Connections 4 10 4 12 Cheetah Xi 50 Board Terminal Connections 4 12 4 13 P2 Relay Connections 4 13 4 14 RS232 Wiring 4 13 4 15 Auxiliary Power Wiring 4 13 4 16 RS485 Peripheral Bus Wiring 4 14 4 17 RS485 DACT Wirin...

Page 9: ... distributor sells installs and services Fike equipment Look on the inside of the door left side there should be a sticker with an indication of the distributor who sold the system If you can not locate the distributor please call Fike Customer Service for locating your nearest distributor or go to our web site at www fike com If you are unable to contact your installing distributor or you simply ...

Page 10: ...igured properly connected and responding properly The system remains in normal state until a trouble condition occurs Notification Appliance A fire alarm system component such as a bell horn speaker light or textual display that provides audible tactile or visible output or any combination thereof The device notifies building occupants of system status This manual interchanges the terms notificati...

Page 11: ...ay Module P N 10 2204 Installation Instructions 06 345 Relay Card P N 10 2785 Installation Instructions 06 586 3 Card Remote Equipment Enclosure P N 10 2780 Installation Document 06 590 5 Card Remote Equipment Enclosure P N 10 2781 Installation Document 06 591 Class A Peripheral Bus Card P N 10 2792 Installation Instructions 06 606 Class A Peripheral Bus Card Assembly P N 10 080 Installation Instr...

Page 12: ...1 0 INTRODUCTION 1 4 Cheetah Xi 50 Installation Manual UL S2203 Rev 6 09 2015 P N 06 369 FM Reserved for future use ...

Page 13: ...ed with one signaling line circuit capable of communicating with 50 addressable devices in any combination EXTERNAL BATTERIES DACT HLI VESDA DETECTOR RS232 LAPTOP PC PROGRAMMING 10 1874B OR RS485 ON BOARD RELAYS ALM TRB SUPV UP TO 253 PROGRAMMABLE ZONES REMOTE DISPLAYS LED GRAPHIC ETHERNET MODULE MULTI INTERFACE SYSTEM PRINTER 24V DC AUX POWER CONTINUOUS 24V DC AUX POWER CONTINUOUS FIRE MM MMM SCM...

Page 14: ...uxiliary power outputs Supports up to 75 AH of batteries SIGNALING LINE CIRCUIT Address devices with Infrared IR tool similar to remote control device non listed One addressable loop 50 devices per loop NFPA Class A B or X with isolator devices True peer to peer digital protocol for extremely fast and reliable communications Addressable Device learn and auto program functions Automatic day night s...

Page 15: ...Sprinkler Systems NFPA 15 Water Spray Fixed Systems NFPA 16 Deluge Foam water and Foam water Spray Systems NFPA 70 National Electrical Code NEC NFPA 70 Article 300 Wiring Methods NFPA 70 Article 760 Fire Protective Signaling Systems NFPA 72 National Fire Alarm and Signaling Code NFPA 101 Life Safety Code NFPA 110 Emergency Standby Power Systems NFPA 750 Standard on Water Mist Fire Protection Syste...

Page 16: ...on Remote Display Exp Protocol O O O O Y Y 10 2630 2 Button Remote Display Exp Protocol O O O O Y Y 68 023 VESDA Open Protocol High Level Interface HLI O O O O Y Y 10 2627 Ethernet Module O O O O Y Y 10 2583 Multi Interface Module O O O O Y Y 10 1XX Intelligent LED Graphic Annunciator O O O O Y Y 10 2667 20 Zone Remote Annunciator O O O O Y Y 10 2792 Note 3 Class A Peripheral Bus Card O O O O Y Y ...

Page 17: ...nch Isolator Version O O O O Y Y 63 1064 EBS Sounder Base 6 inch O O O O Y Y 63 1063 EBR Relay Base 6 inch O O O O Y Y 55 045 Note 1 MMM Mini Monitor Module O O O Y Y Y 55 050 Note 1 MMM Mini Monitor Module Isolator Version O O O Y Y Y 55 041 Note 1 MM Monitor Module 4 inch O O O Y Y Y 55 046 Note 1 MM Monitor Module 4 inch Isolator Version O O O Y Y Y 20 1063 APS Addressable Pull Station O O O O ...

Page 18: ...2 0 SYSTEM OVERVIEW 2 6 Cheetah Xi 50 Installation Manual UL S2203 Rev 6 09 2015 P N 06 369 FM Reserved for future use ...

Page 19: ...tem Ordering Formats Additional system components such as batteries detectors modules cards peripheral devices etc must be ordered separately to suit your specific project requirements 3 2 CHEETAH Xi 50 CONTROLLER The heart of the Cheetah Xi 50 system is the controller See Exhibit 3 3 The system controller consists of a printed circuit board PCB that incorporates the system primary power supply wi...

Page 20: ...designation P on the following pages Controller Specifications Controller Dimensions HxWxD 8 in x 11 in x 3 in 20 3 cm x 27 9 cm x 7 6 cm Weight 1 0 lbs 0 45 kg Power Output 2 Amps Normal Standby 5 25 Amps Alarm Power Consumption 116 mA Normal Standby Operating Environment 32 120 F 0 49 C 93 relative humidity K5 K6 K7 JTAG P10 24V P5 P4 AUX 1 F4 4A P3 P2 10 2620 REV 02 11544 REV A F1 F2 F3 F6 F5 F...

Page 21: ...han 18 AH must be mounted in external battery enclosure Use 14 AWG minimum wire max length of 10 ft 3m to connect batteries to controller P2 Alarm Relay 1 Terminals C NC NO SPDT Form C relay contact DC Operation 5 amps 30 VDC pf 35 AC Operation 0 5 amps 120 VAC pf 35 Default alarm operation configurable All connections shall be power limited or non power limited not both Supervisory Relay 2 Termin...

Page 22: ...mum wire capacitance 0 05uF 100Ω termination resistor is required on the last device on circuit P N 02 2519 supplied with each device T tapping of circuit is NOT allowed Terminal blocks accept 12 24 AWG 24V AUX 1 and 2 shld Power limited and supervised Regulated auxiliary power output rated 24 VDC 1 75A maximum regulated 28 volts maximum Fused by F3 and F4 for short circuit 4A field replaceable fu...

Page 23: ...distance for the installation needs From this information they can determine the total resistance for the circuit Exhibit 3 8 provides the maximum field wiring resistance for total device current that can also be used as a tool 3 2 2 CONTROLLER TEST POINTS VOLTAGES The Cheetah Xi 50 controller has two primary test points While viewing the panel display TP1 is located in the lower right corner of t...

Page 24: ...or Black enamel finish Each enclosure is suitable for surface or flush mounting Numerous conduit knockouts are provided in the back box for easy access to the cabinet during system installation Press studs supplied in enclosure back box for easy installation of system components i e Cheetah Xi 50 control board transformer DACT etc The removable exterior door mounts on the left side of the cabinet ...

Page 25: ...203 Cheetah Xi 50 Installation Manual 3 7 FM P N 06 369 Rev 6 09 2015 Refer to Fike document 06 624 for enclosure installation instructions Exhibit 3 11 Cheetah Xi 50 Enclosure with Dead Front Exhibit 3 10 Cheetah Xi 50 Enclosure ...

Page 26: ...ACT includes five programmable point inputs that can be individually configured to indicate seven types of system conditions Fire Alarm Waterflow Alarm Supervisory Monitor Alarm System Fault AC Failure and Low Battery These inputs can be used in place of the intelligent RS485 connection to provide simple alarm monitoring where the receiving station is not capable of receiving point ID information ...

Page 27: ...ions such as Reset Silence Acknowledge etc Switch functions are protected by the unit s integral security access key In addition the RDU is equipped with an internal piezo and five status LEDs that provide instant audible and visual notification of system status changes Refer to Fike document 06 610 for more information Note This unit can only be used on systems with panel firmware V3 0 or higher ...

Page 28: ... the Cheetah Xi 50 enclosure or it can be mounted remotely by ordering the custom mounting enclosure Refer to Fike document 06 388 for more information 3 5 5 MULTI INTERFACE MODULE P N 10 2583 MULTI INTERFACE MODULE W ENCLOSURE P N 10 069 The Multi Interface Module See Exhibit 3 18 provides an interface point that allows connection of the following ancillary devices to the host control panel 1 Che...

Page 29: ...ividually configured to annunciate the status of the host control panel or an individual zone state event Refer to Fike document 06 453 for more information 3 5 8 RELAY CONTROL ASSEMBLY P N 10 2777 The Relay Control Assembly See Exhibit 3 21 provides a mounting location for up to six 6 CRM4 P N 10 2204 and or HPM4 P N 10 2770 relay modules This configuration allows up to twenty four 24 programmabl...

Page 30: ...ose switching Refer to Fike document 06 586 for more information 3 5 10 CLASS A PERIPHERAL BUS CARD P N 10 2792 The Class A Peripheral Bus Card See Exhibit 3 23 provides a means of wiring the panel s RS485 peripheral bus and 24 VDC power output to the connected peripheral devices in a Class A format The card can be mounted inside the Cheetah Xi 50 enclosure or it can be mounted remotely by orderin...

Page 31: ...ectronics are rated 32 120 F 0 49 C 10 93 relative humidity unless otherwise noted 3 6 1 PHOTOELECTRIC SMOKE DETECTOR P N 63 1052 PHOTOELECTRIC SMOKE DETECTOR WITH ISOLATOR P N 63 1058 The Photoelectric Smoke Detector See Exhibit 3 24 is an intelligent spot type smoke detector that utilizes the light obscuration principle to detect smoke The detector includes a tri color LED for instant indication...

Page 32: ...hance Note Photo element of detector can be programmed as Supervisory and Heat element for Alarm 3 6 4 HEAT DETECTOR P N 60 1039 HEAT DETECTOR WITH ISOLATOR P N 60 1040 The Heat Detector See Exhibit 3 27 is a spot type detector designed to be programmable for a set point range of 135 174 F 57 2 78 9 C for ordinary detection or 175 190 F 79 4 87 8 C for intermediate detection Detectors in the ordin...

Page 33: ...y Night Sensitivity Note Photo Duct Detector can be programmed as a Supervisory input as required by some Local Authority Having Jurisdictions AHJ 3 6 5 1 DUCT DETECTOR HOUSING P N 63 1158 The Duct housing See Exhibit 3 29 is equipped with an integral base for mounting either the P N 63 1057 or P N 63 1062 duct detectors The housing provides a remote alarm output for use with auxiliary devices suc...

Page 34: ...ng enhanced immunity to nuisance particulates FAAST system conditions are displayed at the user interface and at the Cheetah Xi control panel The user interface provides a clear indication of the system status particulate levels alarm levels air flow and faults Features Communicates on the signaling line circuit SLC Unit P N 68 140 monitors up to 8 000 ft 2 743 m 2 with single sampling pipe Unit P...

Page 35: ...ee Exhibit 3 32 can be used with any of the Cheetah Xi 50 detectors It mounts directly to 3 1 2 inch and 4 inch octagon boxes with or without plaster rings and single gang boxes The isolator version provides complete short circuit isolation for NFPA Class X wiring when used with an isolator detector 3 7 3 SOUNDER BASE P N 63 1064 System Sensor EBS The sounder base See Exhibit 3 33 provides the abi...

Page 36: ...moke detectors from a convenient location It mounts directly to single gang electrical box with a minimum depth of 2 5 inches or directly to a wall or ceiling The annunciator is equipped with a red LED that provides visual indication of an alarm condition and a magnetic test function that allows remote testing of the connected detector Special programming is required on the associated DUCT detecto...

Page 37: ...tion A brief description of each addressable module and its features is provided in this section for reference purposes Refer to Fike document 06 369 2 Cheetah Xi 50 Operations Manual for details of module operation and available programming features Refer to installation and maintenance instructions supplied with each module for more information Note Module electronics are rated 32 120 F 0 49 C 1...

Page 38: ...panel accordingly The module includes a tri color LED for instant indication of device status The module is capable of providing an optional pulsing output to signal different states when interfaced with the Cheetah Xi 50 addressable loop The isolator version provides complete short circuit isolation for NFPA Class X wiring A module cover plate not shown is included with the module In addition to ...

Page 39: ...TOR P N 55 053 The Releasing Control Module See Exhibit 3 45 provides an interface between the suppression system solenoid agent release module ARM or impulse releasing module IRM and the addressable loop The module requires 24VDC continuous output power from the panel to power the selected releasing device s The module provides two different output connections solenoid or release module of which ...

Page 40: ...11 1 IR REMOTE TOOL P N 55 051 The IR Remote tool See Exhibit 3 48 is a hand held remote control that is designed to communicate with the panel and other devices through any selected device on the loop It can read device information such as type loop address and sensitivity It can also write device information such as loop address branch and service date and initiate device test It features a 16 c...

Page 41: ...etah Xi 50 controller It provides the designer the tools to design a system in their office and then load the configuration at the project site It also provides the ability to retrieve save and print the configuration and history of events from the control panel as well as perform several diagnostic functions Refer to Fike document 06 448 for more information 3 11 4 INTERFACE CABLE P N 10 2629 The...

Page 42: ...Battery P N 02 4206 75 AH Battery 3 12 3 BATTERY ENCLOSURES Batteries larger than 18 AH will not fit inside the Cheetah Xi 50 panel enclosure s therefore one of the following battery enclosures must be installed to house the batteries Interconnecting cables from the battery cabinet to the Cheetah Xi 50 enclosure shall be in installed in conduit 3 12 3 1 33AH BATTERY ENCLOSURE BATTERIES NOT INCLUDE...

Page 43: ...ring connected Section 4 14 Configure the system Section 4 15 Conduct acceptance testing Section 4 16 Install the dead front panel Section 4 17 4 2 SELECT THE ENCLOSURE MOUNTING LOCATION The mounting location for the Cheetah Xi 50 enclosure is very important Fike recommends that all system enclosures be installed in an area that is readily accessible with sufficient room to allow easy installation...

Page 44: ...sure via knock out openings Conduit knock outs are provided for two distinct conduit sizes Removing just the inside hole creates a one half inch 1 2 opening Removing the entire opening provides a three quarter inch 3 4 opening Note Unless otherwise detailed in this manual or in other documents relating to this control panel the technician shall utilize published standards and references such as NF...

Page 45: ...the System Components section for planning the appropriate wiring for each circuit and device TOP VIEW FRONT VIEW BOTTOM VIEW DOOR FRONT VIEW DOOR SIDE VIEW SIDE VIEW DOOR TOP VIEW BACK BOX Exhibit 4 1 Enclosure Dimensions Size AWG Strands Diameter Uncoated Copper Coated Copper in mm ohm kFT ohm km ohm kFT ohm km 18 1 0 040 1 02 7 77 25 5 8 08 26 5 18 7 0 046 1 16 7 95 26 1 8 45 27 7 16 1 0 051 1 ...

Page 46: ...Interface Connection P4 VESDA HLI Interface P5 Not Used P6 RS 485 Peripheral Buss DACT AUX Power P7 Signaling Line Circuit P8 P9 Notification Appliance Circuits 1 2 1 Connected to power limited or nonpower limited field wiring but not both 2 When the optional DACT module is installed the incoming phone lines power limited must be separated from any nonpower limited P2 relay connections Nonpower li...

Page 47: ...st strap before handling the module s to reduce the risk of damage due to static discharge Note The mounting hardware for installing the panel components is shipped with the system enclosure 4 9 1 INSTALL AC POWER TRANSFORMER The following general steps shall be used to install the AC power transformer into the back box 1 Locate the four threaded press studs provided in the enclosure back box for ...

Page 48: ...eral steps shall be used to connect AC power to the transformer 1 Route the AC hot and neutral wires to the transformer See Exhibit 4 5 2 Secure Hot and Neutral wires to terminals H1 and H2 ICaution Never swap transformer Primary H1 and H2 and Secondary X1 and X2 by connecting AC feed to secondary terminals Doing so will cause the transformer to step up the power resulting in certain damage to the...

Page 49: ... press studs provided in the enclosure back box for mounting the DACT See Exhibit 4 6 and install the four hex stand offs 625 F F 6 32 supplied with the DACT onto the threaded press studs 2 Align the mounting holes provided in the four corners of the DACT with the stand offs and secure in place using the four 6 32 screws supplied with the DACT See Exhibit 4 7 Refer to the installation instructions...

Page 50: ...the enclosure back box for keypad support See Exhibit 4 9 and install the hex stand off 2 5 F F 6 32 supplied with the enclosure onto the threaded press stud 3 Align the mounting holes provided in the four corners of the controller board with the stand offs and secure in place using the four 6 32 hex nuts supplied with the enclosure See Exhibit 4 9 K5 K6 K7 JTAG P10 24V P5 P4 AUX 1 F4 4A P3 P2 10 ...

Page 51: ... controller 1 Connect wiring from the secondary side of the AC power transformer X1 and X2 to the controller s P1 24VAC Secondary terminals See Exhibit 4 10 making sure to land wires to the correct terminals ICaution The transformer input should never be connected to the battery input Reversing the AC and Battery input will damage the controller 2 Do NOT energize the AC power source at this time P...

Page 52: ...1 negative battery input terminal to the negative terminal of the second battery 4 A jumper is supplied to provide the connection between the negative terminal on the first battery to the positive terminal on the second battery Do NOT install this jumper at this time 4 11 1 BATTERY CUTOFF The Cheetah Xi 50 panel has battery cutoff feature that allows the system batteries to be automatically discon...

Page 53: ...uld illuminate because the batteries are not connected 2 Install the supplied jumper cable between the negative terminal of the first battery to the positive terminal of the second battery 3 With the batteries connected verify that the only the system AC POWER LED is illuminated 4 Identify and fix any problems indicated by the controller 5 Power down the controller by first disconnecting the batte...

Page 54: ...al function for reference purposes P6 24VDC AUXILIARY POWER 1 P1 BATTERY CONNECTIONS P1 AC POWER CONNECTIONS P6 DACT INTERFACE P7 SIGNALING LINE CIRCUIT P9 NOTIFICATION APPLIANCE CIRCUIT 2 P5 NOT USED P4 VESDA HLI INTERFACE RS232 P3 PANEL PROGRAMMING INTERFACE P10 FIKE USE ONLY P2 DRY CONTACT RELAYS 10 2620 REV 02 11544 REV A F1 F2 F3 F6 F5 F4 CHEETAH Xi 50 FIKE CORPORATION 01 39 37A 06 14 2011 AL...

Page 55: ...d for programming the panel using the C Linx software USB programming cable P N 10 2629 or equivalent must be used for this connection P4 RS232 jack dedicated for connection to a VESDA network via a VESDA HLI interface A 14 ft 4 27m serial cable P N 02 3053 is provided with the HLI for connection to the controller The HLI is considered a permanent connection to the RS232 port P4 and shall be locat...

Page 56: ... be connected in a daisy chain configuration as shown in Exhibit 4 16 These connections are all supervised and power limited Do not branch or star tap the peripheral bus 4 13 5 DACT WIRING P6 The panel provides a dedicated connection point for the optional internal Digital Alarm Communicator Transmitter See Exhibit 4 17 Refer to Fike document 06 479 for more details Exhibit 4 16 P6 RS485 Periphera...

Page 57: ...d cable help prevent electrical interferences from being induced Shielded wire is not required but if used install the outgoing drain wire at the panel Connect it through and insulate at each junction box and leave unconnected and insulated at the last device FM Approved Deluge and Pre action Sprinkler operation requires that initiating device circuits be Class A and wired to FM Listed Approved de...

Page 58: ...st a single short circuit Short circuit protection can be provided for the entire signaling line circuit or for selected sections of the signaling line circuit Isolator devices can be installed to electrically isolate a zone of detectors and or modules from the remainder of the loop by installing an isolator type device at the point where the SLC enters and leaves the zone A maximum of 50 devices ...

Page 59: ...l devices This is accomplished without requiring purchase and installation of a separate sync module Both circuits must be programmed to use the same manufacturers sync pulse if this option is used 4 14 INITIAL POWER UP WITH FIELD WIRING CONNECTED 1 Energize AC power to Cheetah Xi 50 controller and field power supplies if installed with field wiring connected 2 Connect batteries to the Cheetah Xi ...

Page 60: ...e system are installed and operating as intended Where test results differ from those expected corrective action must be taken Before commencing testing notify all areas where the alarm sounds and off premises locations that receive alarm and trouble transmissions that testing is in progress When the system has been tested and found to operate satisfactorily a Record of Completion document referen...

Page 61: ...d Alarm Capacity Amp hr Total Required Capacity Amp hr Optional Factor of Safety Adjusted Battery Capacity Amp hr x Note 6 Note 7 Notes 1 Auxiliary Power cannot exceed 1 75 A in normal standby condition 2 Auxiliary Power plus Notification Power cannot exceed 5 25 A 3 Auxiliary Power does not include current delivered to SCM during alarm conditions This current is totaled in Section 4 0 Notificatio...

Page 62: ... 0 170 x 15 55 052 053 RCM Note 3 0 450 x 6 000 x 16 63 1064 Sounder Base Note 1 0 300 x 0 300 x 17 02 3868 Remote Annunciator NA x NA NA 10 000 x 18 02 3869 Remote Test NA x NA NA 10 000 x 19 02 4998 Remote Key Test NA x NA NA 12 000 x Total SLC Standby Current mA Total SLC Alarm Current mA Total SLC Standby mA 1000 A Total SLC Alarm mA 1000 A Total Total Insert totals in Section 1 Line Item 2 No...

Page 63: ...0 134 x 13 10 2583 Multi Interface 0 200 x 0 200 x 14 10 2411 LED Graphic Micro 0 067 x 0 140 x 15 10 2667 20 Zone Remote Annun 0 051 x 0 148 x 16 10 2785 Relay Card Note 5 0 032 x 0 256 x 17 10 2777 Relay Assy Note 4 0 047 x 0 109 x 18 10 2204 CRM4 Relay Note 5 0 011 x 0 040 x 19 10 2770 HPM4 Relay Note 5 NA x NA NA 0 086 x 20 10 2792 Class A Peripheral 0 057 x 0 057 x 21 10 2814 LOC Digital Pagi...

Page 64: ... 17 x 18 x 19 x 20 x 21 x 22 x 23 x 25 x 26 x 27 x 28 x 29 x 30 x 31 x 32 x 33 x 34 x 35 x 36 x 37 x 38 x Total NAC Power Standby Current Amps Total NAC Alarm mA 1000 A Total Insert totals in Section 1 Line Item 4 Notes 1 Include current draw of all notification appliances connected to the Cheetah Xi 50 s two on board notification appliance circuits NAC 1 2 and to addressable Supervised Control Mo...

Page 65: ...Xi 50 system The operational posting can also be downloaded from Fike Forums web page document P N 06 650 For a detailed description of the operation of the Cheetah Xi 50 system refer to Fike document 06 369 2 Cheetah Xi 50 Operation and Maintenance Manual for more details The completed System Operation Posting shall either be mounted on the cabinet front or framed and located adjacent to the cont...

Page 66: ...APPENDIX B B 2 Cheetah Xi 50 Installation Manual UL S2203 Rev 6 09 2015 P N 06 369 FM Reserved for future use ...

Page 67: ...ble Condition Activation of a trouble signal under normal operation indicates a problem with the system not an alarm that requires immediate attention Contact your local service representative In most trouble conditions the fire suppression system continues to provide protection to the building and its occupants however trouble conditions should not be allowed to remain and should be investigated ...

Page 68: ...so indicate a Trouble and Supervisory event when a zone is disabled Turns off when the panel is reset or the zone is enabled Abort Yellow LED that flashes when the panel enters the Abort state Illuminates steady after you acknowledge or silence the event Turns off if the abort condition clears and no other abort events are present Ground Fault Yellow LED that illuminates steady when a ground fault...

Page 69: ...l c R Red B Black 02 10881 Transformer 120VAC primary 02 10882 Transformer 240VAC primary OPTIONAL MODULES 10 2528 DACT Bosch FPT DACT LC 5 zone with Serial interface for internal mounting 10 2476 DACT Bosch FPT DACT 5 zone with Serial interface w enclosure for external mounting PERIPHERAL BUS DEVICES 10 2646 14 Button Expanded Protocol Remote Display Unit 10 2631 10 Button Expanded Protocol Remot...

Page 70: ...ith Isolator 63 1158 DUCT Detector Housing must be used with 63 1057 63 1062 68 140 FAAST Aspirating Smoke Detector 68 302 FAAST XT Aspirating Smoke Detector DUCT DETECTOR ACCESSORIES 02 3868 Remote Annunciator LED 02 3869 Remote Test Station 02 4998 Remote Test Station with Key 63 1159 Sampling Tube Duct Detector up to 1 ft 0 3m 63 1160 Sampling Tube Duct Detector 1 ft to 2 ft 0 3m 0 6m 63 1161 S...

Page 71: ...er 02 11139 without 10 1874A interface cable 10 2629 USB A B Cable for configuration of Cheetah Xi 50 System 10 2477 DACT Programmer Bosch FMR DACT KEYPAD BATTERIES AND BATTERY ENCLOSURES 10 2626 12 AH Battery Assembly w wiring assembly 10 2190 2 18 AH Battery Assembly w wiring assembly 10 2192 Wiring Assembly for 7 2 AH and 18 AH Batteries wire only 10 2517 Wire Assembly with Battery EOL 02 2018 ...

Page 72: ...ell 3V 10 2625 Monitor and Control Module EOL Assembly 39K 10 2530 14KΩ Series Resistor for Monitor Module Short Circuit detection 10 2570 End of Line Resistor 1 2 K for NAC 1 2 02 4174 Fuse 15 Amp Mini Auto Fast Acting For F1 F2 Little fuse p n 297015 02 11412 Fuse 4 Amp Mini Auto Fast Acting For F3 5 Little fuse p n 297004 02 4981 End Of Line Relay System Sensor EOLR 1 02 2519 Termination Resist...

Page 73: ...tah Xi 50 control panel TOP LOOP ADDRESS RELAY MULTI VOLTAGE RELAY P N 20 1173 BATTERY BATTERY 24 VDC AUXILIARY POWER OUTPUT BATTERY CONNECTION CONTROL PANEL RELAY MODULE TERMINAL DEFINITIONS T1 SLC IN OUT T7 NC 1 T2 SLC IN OUT T8 C 1 T3 SLC IN OUT T9 NO 1 T4 SLC IN OUT T10 NC 2 T5 DRY CONTACT INPUT T11 C 2 T6 DRY CONTACT INPUT T12 NO 2 SLC IN SLC OUT OR P N 20 1177 Exhibit D 1 Battery Cutoff Wiri...

Page 74: ...APPENDIX D D 2 Cheetah Xi 50 Installation Manual UL S2203 Rev 6 09 2015 P N 06 369 FM Reserved for future use ...

Page 75: ......

Page 76: ...704 SW 10 th Street P O Box 610 Blue Springs Missouri 64013 Tel 816 229 3405 Fax 816 229 0314 www fike com ...

Reviews: